• Title/Summary/Keyword: 일반촬영

Search Result 608, Processing Time 0.019 seconds

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

General Radiography Examination Statistical analysis of Patients in Geriatric hospitals (노인요양병원 내원환자의 일반촬영 통계분석)

  • Kim, Kyuhyung;Lee, Junhang;Kim, Youngwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • The purpose of this study is to establish the basic data for the management of the elderly patients aged more than 60 suffering from musculoskeletal disorders in geriatric hospitals. From January, 1 2012 to December 31, 2012, 2,500 patients who were taken the x-ray inspection and were analyzed x-ray order 5,042 cases above spines, upper lower extremities and joints. The elderly age was divided into 3 groups according to Brody elderly statistics. The majority of elderly patients who visited the hospital are exposed to spinal disorders and joint diseases. Shoulder, knee, L-spine examination cases had accounted for more than half the number of total. By age group, the number of the first quarter was most dominant commonly. Second and third quarter was maintaining slightly decrease. The fourth quarter had reduced compared to the first quarter. If the visiting purposes and the disease causes analysis and preventive measures are taken in a study, it is expected to utilize as basic data to make a plan of the education for preventing diseases and elderly behavior planning for geriatric hospitals and to redistribute health care resources of the rural areas efficiently.

An Assessment of Entrance Surface Dose Using the nanoDot Dosimeter (나노도트선량계를 이용한 입사표면선량의 평가)

  • Kim, Jong-Eon;Im, In-Chul;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.377-381
    • /
    • 2011
  • The purpose of this study is an assessment between the measured value of the nanoDot dosimeter and the calculated value of Non Dosimeter Dosimetry-Method(NDD-M) for entrance surface dose in general radiography. Measurement and calculation of the entrance surface doses were performed for head(AP), abdomen(AP), pelvis(AP), thoracic spine(AP) and lumbar spine(AP). As a result, the relative ratios of the measured value to the calculated value were acquired 1.5-2.1 for each region. Reproducibility acquired 0.035 as a coefficient of variation.

Clinical and Radiologic Findings of COVID-19 Pneumonia: South Korean Experience from Three Cases (코로나바이러스감염증-19의 임상적 소견 및 영상의학적 소견: 세 증례를 통한 한국의 경험)

  • Hyung Ju Lee;Jung Won Moon;Ji Young Woo;Yoo Na Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.583-590
    • /
    • 2020
  • Coronavirus disease 2019 (COVID-19) is spreading rapidly around the world. Several articles have so far reported on radiological findings of COVID-19 pneumonia. Herein, we present three cases of COVID-19 pneumonia in South Korea, and provide clinical information as well as chest radiograph and chest CT findings.

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

A Study on Radiation Beam Quality Set-up of Mammography Equipment and Average Glandular Dose (유방 촬영 장치의 국제 규격 Beam Quality 기준에 따른 평균 선량 평가에 관한 연구)

  • Park, Yoon-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Mammography using X-rays is currently the most used for early diagnosis of breast cancer. As the frequency of use of X-ray devices increases, interest in radiation hazards caused by mammography is increasing. Therefore, in this study, in order to measure the exposure dose of the mammary gland in X-ray mammography that requires high contrast and high resolution, the international Atomic Energy Agency (IAEA) stipulates the international standards presented by IEC 62220-1-2: 2015. Based on the beam quality criteria of the recommendation, we tried to present a guideline for evaluating the average mammary gland dose. As a result, the average streamline dose value of the 4.5 cm PMMA phantom was 2.3 mGy at the maximum within the 30 kV range, and was evaluated to be 1.19 mGy based on 28 kV.

Image Processing Technique for Measuring the Static Displacement of Bridges from General Inspection Photograph (일반 점검사진에서 교량의 정적 변위 추출을 위한 영상처리기법)

  • Cho, Jun Sang;Huh, Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.173-180
    • /
    • 2011
  • This paper aims to propose an image processing technique for measuring the static displacement of bridges from general inspection photograph; the color, shape, and spatial transformations of an arbitrary image stored in bridge management system database are used. This study is verified by using numerical analyses with experiments; the results demonstrate that the static displacement of bridges are measured by proposed technique. Moreover, this technique is able to obtain the static structural response of the bridge with changes in temperatures.