• Title/Summary/Keyword: 일반촬영

Search Result 608, Processing Time 0.028 seconds

Design and Implementation of Embedded Linux-based Personal Mobile Broadcasting Service (임베디드 리눅스 기반의 개인 모바일 방송국 서비스 설계 및 구현)

  • Kim, Do-Hyung;Kim, Sun-Ja;Lee, Cheol-Hoon
    • The KIPS Transactions:PartD
    • /
    • v.16D no.3
    • /
    • pp.441-450
    • /
    • 2009
  • This paper describes the design and implementation of Personal Mobile Broadcasting Service which bases on embedded Linux and it supports personal broadcasting in wireless network environments. Recently, with the advent of various wireless networks and the increased use of high performance mobile devices, the demand for personal mobile broadcasting is being increased. The personal mobile broadcasting service makes it possible that mobile users create contents using their own mobile devices while they are moving or they are in any place. And then, it sends the created contents to server in real-time where their blogs are. Users connected to the content creator's blog can play the contents in real-time. With the implemented personal mobile broadcasting service, mobile users can share multimedia contents in real-time through wireless networks. And, it also helps users to construct their own broadcasting stations where they can broadcast the scene of the accident or public performance in real-time.

Objective Quality Assessment Method for Stitched Images (스티칭 영상의 객관적 영상화질의 평가 방법)

  • Billah, Meer Sadeq;Ahn, Heejune
    • Journal of Broadcast Engineering
    • /
    • v.23 no.2
    • /
    • pp.227-234
    • /
    • 2018
  • Recently, stitching techniques are used for obtaining wide FOV, e.g., panorama contents, from normal cameras. Despite many proposed algorithms, the no objective quality evaluation method is developed, so the comparison of algorithms are performed only in subjective way. The paper proposes a 'Delaunay-triangulation based objective assessment method' for evaluating the geometric and photometric distortions of stitched or warped images. The reference and target images are segmented by Delaunay-triangulation based on matched points between two images, the average Euclidian distance is used for geometric distortion measure, and the average or histogram of PSNR for photometric measure. We shows preliminary results with several test images and stitching methods for demonstrate the benefits and application.

Extraction of Road Facility Information Using Multi-Imagery (다중영상을 이용한 도로시설물 정보추출)

  • Sohn, Duk-Jae;Yoo, Hwan-Hee;Lee, Hey-Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.1 s.19
    • /
    • pp.91-100
    • /
    • 2002
  • Recently, many studies on the construction of management system for road facility have been accomplished, and in its process the digital map is used as the essential data for spatial database. But in case where the existing topographical map or completion map of construction data is not sufficient for Data Base construction, the compilation, modification or renewal of digital map should be conflicted with large obstacles. This study intended to extract the road facility information using the image data of various form such as aerial photographs, terrestrial photographs and so on. The terrestrial photographic images are taken by hand-held camera, digital camera and video camera which are widely used and of low price in general. This study used the single frame images only for the raw image data, and the extracted spatial and attribute data from the images are used for modifying and updating the database. In addition, the creating possibility of the digital map in the relative scale using the spatial data extracted from the single images was tried.

  • PDF

Development of 80W LED Lighting Equipment for Broadcasting System (방송시스템용 80W LED 조명장비의 개발)

  • Lee, Dong-Yoon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.506-511
    • /
    • 2017
  • LED lighting, which many companies are pursuing commercialization, is a representative green energy technology. However, the LED lighting for broadcasting image should have high output and easy portability compared with general LED lighting devices for street lamps, advertisement or transportation devices. Therefore, while shooting a broadcast image if you use LEDs as a substitute light source for halogen lamps and fluorescent lamps that are large in size and uncomfortable to handle it is expected that the lightening of the equipment will activate the broadcasting image lighting equipment industry. After considering the mass production of the LED module board and the SMT production size of the chip mounter, the board size was determined considering the overall size of the product by model. In this paper, four 20W LED boards are arranged vertically in order to produce an 80W board. In other words, by sharing LED module board size by model, high power LED lighting equipments of 120W and 200W can be selected as an increase in the number of boards.

Using Optical Flow and HoG for Nighttime PDS (야간 PDS를 위한 광학 흐름과 기울기 방향 히스토그램 이용 방법)

  • Cho, Hi-Tek;Yoo, Hyeon-Joong;Kim, Hyoung-Suk;Hwang, Jeng-Neng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1556-1567
    • /
    • 2009
  • The death rate of pedestrian in car accidents in Korea is 2.5 times higher than the average of OECD countries'. If a system that can detect pedestrians and send alarm to drivers is built and reduces the rate, it is worth developing such a pedestrian detection system (PDS). Since the accident rate in which pedestrians are involved is higher at nighttime than in daytime, the adoption of nighttime PDS is being standardized by big auto companies. However, they are usually using night visions or multiple sensors, which are usually expensive. In this paper we suggest a method for nighttime PDS using single wide dynamic range (WDR) monochrome camera in visible spectrum band. In our experiments, pedestrians were accurately detected if only most edges of pedestrians could be obtained.

Right Pulmonary Artery Agenesis - A case report - (우측 폐동맥 형성부전증 - 1예 보고 -)

  • Kim, Hyuck;Wee, Jang-Seop;Kim, Young-Hak;Chung, Won-Sang;Nam, Seung-Hyuk;Kang, Jeong-Ho
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.52-55
    • /
    • 2007
  • Unilateral pulmonary artery agenesis is a rare congenital malformation usually associated with other cardiovascular anomaly such as Tetralogy of Fallot. Isolated pulmonary artery agenesis is very rare, and usually asymptomatic. It is usually highly suspected by routine chest X-ray, and associated symptoms are hemoptysis, blood tinged sputum, repeated pulmonary infection, and dyspnea on exertion. We have recently experienced the right pulmonary artery agenesis in 27 year-old male patient, complaining of minimal hemoptysis and sustained blood tinged sputum. He was successfully treated by right pneumonectomy, so we report this case with the review of associated literature.

Experimental Study on Vertical Velocity Distribution in the Open Channel with Smooth bed Using PIV Technique (매끄러운 하상의 개수로에서 PIV 기법을 이용한 연직유속분포의 실험적 연구)

  • Byun, Hyun-Hyuk;Yoon, Byung-Man;Ji, Un
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.614-614
    • /
    • 2012
  • 개수로에서 혹은 수리구조물 주변에서의 흐름 및 난류 특성을 파악하기 위해서는 연직유속분포 및 수심별 평면유속분포의 측정이 필요하다. 유속분포를 측정하기 위한 방법은 음파 도플러 유속계(ADV:Acoustic Doppler Velocimetry)를 사용하는 방법과 PIV 기법을 이용하는 방법이 있다. 일반적으로 ADV는 한 지점의 유속을 시간변화에 따라 연속적으로 측정할 수 있어 난류특성의 정량적인 해석에 장점이 있으나 동시간에 여러 지점을 측정할 수 없기 때문에 난류의 공간적인 문제를 해석함에 있어서 한계가 있다. 그러나, 입자영상유속계(PIV:Particle Image Velocity)는 측정하고자 하는 단면에서 연직 횡단면의 유속분포 및 수심별 평면 유속분포 흐름장 측정이 가능하여 난류흐름의 공간적인 문제를 해석하는데 효과적일 뿐만 아니라 영상간의 시간간격을 짧게 하고, 촬영시간을 충분히 길게 한다면 개수로 내 난류특성 분석도 가능하다. 이에 본 연구의 목적은 PIV 기법을 이용하여 매끄러운 하상의 개수로에서 연직유속분포를 측정하고 그 특성을 정량적으로 분석하고자 한다. 본 연구에서는 첫째, PIV 기법을 이용하여 측정한 연직유속분포와 3차원 전자식 유속계를 이용하여 측정한 연직유속분포를 비교 분석하였다. 둘째, 후류법칙에 의해 계산된 연직유속분포와 PIV 기법을 이용하여 측정한 연직유속분포의 비교를 위해 각각의 무차원 유속분포(지점 유속/지점 마찰속도)를 계산하고 비교하였다. 마지막으로 각 흐름 조건에 따라 수심의 변화를 주어 연직유속분포를 PIV 기법으로 측정한 후 개수로의 수심변화에 따른 연직유속의 특성을 분석하였다. 분석 결과, PIV 기법을 이용하여 측정한 연직유속 성분에 비해 3차원 전자식 유속계로 측정한 연직유속 성분이 작게 나타났고 바닥에서부터 0.2h 지점까지는 무차원 유속분포(지점 유속/지점 마찰속도)가 후류법칙과 잘 맞는 경향을 보였으나 0.2h 지점부터 수표면까지는 유속이 감소하는 현상이 나타났다.

  • PDF

X-ray Radiography에 적합한 Double Multilayer Monochromaotr (DMM) 설계와 제작

  • Jeong, Sun-Yong;Yang, Seong-Seon;Im, Jae-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.118-118
    • /
    • 2013
  • DMM은 방사광가속기의 백색광으로부터 단색광을 추출하기 위해 두 개의 다층 박막 (multilayer) 거울을 사용하는데, 첫 번째 거울은 Bragg 반사를 통해 분광을 하여 단색광을 생산하는 용도이고, 두 번째 거울은 이 단색광을 반사시켜 지면과 평행하게 출사되게 하기 위함이다. 일반적으로 사용되는 DCM (Double Crystal Monochromator)과의 차이점은, Bragg 반사를 위해 DCM에서는 결정을 사용하는 반면 DMM은 밀도차이가 많이나는 두 종류의 물질을 교대로 쌓아 올린 다층 박막을 사용한다는 것이다. 다층 박막의 주기가 곧 Bragg 반사에서의 d-spacing이 되며, X-선 분광의 목적으로 사용되는 d-spacing은 10-50 $\AA$ 사이이다. DCM이 0.01% 대의 우수한 에너지 분해능을 보이는데 비해, DMM은 1% 정도이다. 이 때문에 출사광의 밝기가 DCM에 비해 100배 밝은 특징이 있어서 에너지 분해능보다 광량이 더 중요한 응용에서 DMM이 사용된다. X-선 영상이나 방사선치료가 바로 이러한 응용에 해당한다. DMM은 포항가속기연구소와 (주) 벡트론에서 공동 설계하였으며, (주)벡트론에서 제작하였다. 그림 1에 DMM의 외형과 내부 구조를 나타내었다. Bragg 각의 조절 범위는 0.24-0.9도 이다. 입사광과 출사광의 수직 방향 offset을 10 mm로 유지하기 위해 두 번째 다층 박막이 수평방향으로 1,000 mm 가량 이동할 수 있어야 한다. 이를 위해 두 대의 고니오미터 stage를 사용하여 각각 첫 번째 및 두 번째 다층 박막의 위치와 방향을 제어한다. 첫 번째 다층 박막을 제어하는 고니오미터 stage는 하부가 전체 프레임에 고정되어 있고, 이 고니오미터의 회전축에서 Bragg 각을 조절한다. 두 번째 다층 박막을 제어하는 고니오미터 stage는 높이방향과 수평방향으로 이동이 가능하다. 다층 박막의 pitch는 고니오미터의 회전축에서 조절한다. 그리고 tilt stage를 사용하여 다층 박막의 roll을 조절한다.

  • PDF

Segmentation and Volume Calculation through the Analysis of Blurred Gray Value from the Brain MRI (뇌의 MR 영상에서 번짐 현상의 명암 값 분석을 통한 백질과 회백질의 추출 및 체적 산출)

  • Sung, Yun-Chang;Yoo, Seung-Wha;Song, Chang-Jun;Park, Jong-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.815-826
    • /
    • 2000
  • This study is for the segmentation and volume calculation of the white matter and gray matter from brain MRI. In general, the volume of white and gray matter is reduced by contraction of each components in the case of mental retardation which are Alzheimer's disease and Down's syndrome. As results, it is useful for diagnostic and early detection for various mental retardation through the tracing of variation for its volume from the brain MRI. But, until now, it was very difficult to calculate the partial volume of each components existing in some thickness, because MR image was represented by single gray value after scanning by MR scanner. Accordingly, new segmentation algorithm proposed in this paper is to calculate the partial volume of the white and gray matter existing in some thickness through the analysis of the blurred gray value, and is to determine the threshold for segmentation of white and gray matter, and is to calculate the volume of each segmented component. And finally, proposed algorithm was applied the models which was created manually, and then acquired results was compared with that of original model.

  • PDF

A Study on Effects of Using In Coated Wire on Arc Stability in GMAW (In 도금 와이어가 GMAW용접의 아크 안정성에 미치는 영향에 관한 연구)

  • Choi, Dong-Soon;Hwang, Ji-Hye;Kim, Hyun-Jae;Kim, Jae-Seong;Lee, Bo-Young
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.65-65
    • /
    • 2009
  • 철강 재료의 GMA 용접 시, 보호가스로 $CO_2$ 가스를 사용하면 가격이 저렴하고 용입이 깊다는 장점이 있어 국내에서 광범위하게 사용되어 왔다. 그러나 일반적으로 활성가스인 $CO_2$를 사용한 GMA용접은 아크가 불안정하고 스패터가 많이 발생한다는 단점이 있어 아크 안정성 개선의 필요성이 부각되었다. 거기다 용접 자동화 및 용접 품질의 고급화 추세로 아크 안정성이 $CO_2$용접에서 점점 중요해지면서, 아크 안정화 및 스패터 저감을 위한 연구가 활발히 진행되어 왔다. 본 연구에서는 GMA 용접 재료인 solid wire의 표면에 이온화 에너지가 낮은 금속인 인듐(In)을 전해 도금하여 중전류의 $CO_2$ 용접에 적용하였다. 고속 촬영과 아크 모니터링 분석을 통하여 금속 이행 모드 및 아크 안정화에 미치는 영향에 관하여 연구하였다. 동일 전압, 전류 조건에서 도금 두께를 달리하여 용접을 실시, 도금 두께에 따른 아크 안정성의 경향을 분석하였다. 그 결과 도금 두께가 두꺼워짐에 따라 아크가 넓어지는 것을 확인하였으며, 이는 아크 내에 이온화도가 높은 인듐 이온이 다량 포함됨으로써 이온의 양이 증가하기 때문인 것으로 생각된다. 또한 도금 두께가 일정 이상이 되면, 이행 모드가 용적의 아래에서 아크가 발생하는 반발 이행 모드에서 용적의 윗부분에서 아크가 발생하는 입상 용적 이행 모드로 바뀌었으며, 이때 단락 수가 현저히 줄어들어 아크가 안정해졌다. 이에 따라 인듐 도금 와이어는 기존보다 낮은 전류 영역에서도 안정적인 아크와 금속 이행 모드를 가지게 됨을 확인하였다.

  • PDF