• Title/Summary/Keyword: 일반방사선촬영

Search Result 196, Processing Time 0.027 seconds

Assessment of Radiation Dose Due to X-Ray Simple Series Examinations (X-선 단순 Series 촬영 시 피폭 선량 평가)

  • Gang, Eunbo;Hwang, Incheol;Shin, Woonjae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • In diagnostic radiology, each part is examined through serial radiography in most cases of general radiography. However, the reality is that, as for diagnostic reference level, measured values have been set up only for AP projection of each part and lateral projection. In the clinical setting, cumulative dose is incurred by serial radiography of patients, and this can make comparison of diagnostic reference level and cumulative exposure dose impossible or can lead to underestimation of diagnostic reference level. In this study, measurement of cumulative dose of serial radiography of each part revealed that when converting entrance surface dose to effective dose in case it is included in the exposure field, cumulative dose measured from a maximum of 38.06% to a minimum of 0.23% of individual dose limitation of the public. Also, when converting entrance surface dose of each part that is not included in the exposure field into effective dose, it measured from a maximum of 5% to a minimum of 0.04% of individual dose limitation of the public. Results of this study show entrance surface dose substantially increases in serial radiography of each part. Therefore, it is deemed that hospitals need to establish diagnostic reference level specifically, and subdivision of radiography orders for patients is also required in order to reduce unnecessary inspections. Moreover, the need of accurate exposure field is emphasized in case of inspection of several parts.

A Study on Radiological Image Retrieval System (방사선 의료영상 검색 시스템에 관한 연구)

  • Park, Byung-Rae;Shin, Yong-Won
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2005
  • The purpose of this study was to design and implement a useful annotation-based Radiological image retrieval system to accurately determine on education and image information for Radiological technologists. For better retrieval performance based on large image databases, we presented an indexing technique that integrated $B^+-tree$ proposed by Bayer for indexing simple attributes and inverted file structure for text medical keywords acquired from additional description information about Radiological images. In our results, we implemented proposed retrieval system with Delphi under Windows XP environment. End users, Radiological technologists, are able to store simple attributes information such as doctor name, operator name, body parts, disease and so on, additional text-based description information, and Radiological image itself as well as to retrieve wanted results by using simple attributes and text keywords from large image databases by graphic user interface. Consequently proposed system can be used for effective clinical decision on Radiological image, reduction of education time by organizing the knowledge, and well organized education in the clinical fields. In addition, It can be expected to develop as decision support system by constructing web-based integrated imaging system included general image and special contrast image for the future.

  • PDF

Analysis on infection control of general hospital radiology (종합병원 영상의학과의 감염관리 대한 분석)

  • Shin, Jung-Sub;Park, Cheol-Woo;Jeon, Byeong-Kyou
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.335-342
    • /
    • 2012
  • This study aims to find a way to control infection of community radiology effectively by calculating the degree of contamination, culture and identifying the flora in radiology of five general hospitals in Gyeongsangbuk-do. Staphylococcus, Micrococcus, Pseudomonas stutzeri, Pseudomonas oryzihabitans were identified as surface flora. These are know to be pathogens of hospital acquired infection and there was no radiology-specific flora. Research subject hospitals were conducting similar infection control education but degree of contamination of each hospital showed significant difference. Difference in degree of contamination according to contact sources were analyzed by Contact sources were classified into technologist-using, patients-using and common-using materials. Analysis of each hospital's degree of contamination showed that patient-using materials were significantly more contaminated than technologist-using and common-using materials (p<0.001). Devices which are similar to each other in monthly average frequency of use showed no significant difference in degree of contamination, but general X-ray devices and chest boards which are used most frequently showed higher degree of contamination than others. In addition, hospital A, B and C which have heavier monthly average caseload showed relatively high degree of contamination on irradiation devices which are used by technologists only or by technologists and patients commonly, office desks and doorpulls. Hence it is considered that intensity of infection control education should be different according to the degree of monthly average caseload. This study provided an opportunity to aware that technologists' feeling of contamination is crucial for infection control of radiology, and the Accupoint ATP public hygiene monitoring system which was used in this study for measuring the degree of contamination was proved to be an effective measuring device for hospital acquired infection management.

Evaluation of Dose and Image Quality of Lens according to Baseline during Brain CT Scan (두부 전산화단층촬영 시 기준선에 따른 수정체 선량과 화질 평가)

  • Kim, Kyu-Hyung;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.699-704
    • /
    • 2019
  • It is important to minimize the exposure dose during an examination and obtain good quality images at the same time. This study compared the beam harding effect according to the baseline superior orbito meatal line(SOML), orbito meatal line(OML), inferior orbito metal line(OML) and measured the exposure dose of the lens, especially in brain CT examinations, which generally apply to head diease patients. The beam harding effect assessment of each image along the baseline was performed quantitatively using the Image J program, and the exposure dose of the lens was detected by OSLDs and compared. As a result, As a result, when the SOML was used as the reference line, the dose of the lens was decreased by 85.08% at 80 kV and by 79.7% at 80 kV, compared to when IOML was used as the baseline. If the gantry angle at brain CT was parallel scan to SOML, there were no significant differences in the exposure to the lens and between the OML and IOML. Therefore, this study has shown that it is efficient to have a parallel scan on SOML as a protocol during Brain CT examinations.

Radiological Perspectives for Diagnosis of Vasospastic Angina with Coronary Angiography (이형성 협심증 진단 조영 검사의 방사선학적 관점)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.589-595
    • /
    • 2023
  • If complete coronary artery occlusion occurs due to severer coronary spasm, malignant arrhythmias can lead to death. Therefore, early screening for coronary artery spasm angina is essential. Among the test methods, the drug injection test through coronary angiography is generally performed. Therefore, the purpose of this study was to evaluate the advantages of ergonovine drug test for vasospasitc angina examination during coronary angiography, such as the relationship between the procedure time, contrast medium usage, and radiation exposure effects of coronary angiography. Follow-up data of 142 patients who underwent coronary angiography and variant angina examination from september 2021 to february 2023 were used. As a result of analyzing contrast usage dose and dose area product and air kerma dose and number of imaging series and procedure time, variant angina examination was statistically significantly higher than coronary angiography. (p<0.001) In conclusion, variant angina examination other than coronary artery angiography are radiologically negative. Therefore, we think it is better to avoid excessive inspection. Nevertheless, in the case of the provocation test, the longer the examination time, the higher the fluoroscopy time and the amount of contrast medium used, so it is better to conduct the test as quickly as possible or shorten it.

Radiographic Evaluation and Triple Pelvic Osteotomy for the Treatment of Immature Canine Hip Dysplasia (어린 개 고관절 이형성의 방사선 평가 및 3중 골반골 절단술에 의한 치료)

  • 김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.370-375
    • /
    • 1997
  • 8개월령의 체중이 40.4kg인 로트와일러 수컷 어린개와 9개월령의 체중 34.6kg인 골 든 레트리버 수컷 어린개가 각각 2주령과 1개월령부터 파행 및 통증을 주중으로 머독대학 동물 병원에 내원 하였다. 내원 했을 때 호흡과 심박수 및 체온은 정상이었다. 일반 보행 및 신경검사 와 방사선 사진을 촬영하여 확인한 결과 양측 고관절 이형성(Hip displasia)과 퇴행성 관절질환 (Degenerative joint disease)을 확인 할 수 있었으며, 그 증상의 정도는 우측에 비하여 좌측이 더 심하게 나타냈다. 외과적 치료는 Slocum과 Devine에 의한 3중 고관절 절단술(Triple pelvic osteotomy)를 실시하였으며 특별한 외부 고정은 하지 않았다. 수술 후 5개월 동안 지켜본 결과 증 상은 매우 좋아졌으며 골반골의 완벽한 고정 유지에 따른 교정된 고관절을 확인 할 수 있었다.

  • PDF

Image Analysis of Angle Changes in the Forearm during Elbow Joint Lateral General Radiography: Evaluation of Humerus Epicondyle and Elbow Joint (팔꿉관절 측방향 일반촬영에서 아래팔뼈 각도 변화에 따른 영상 분석 : 위팔뼈 위관절융기와 팔꿉관절 평가)

  • Hyo-Soo Shin;Hye-Won Jang;Jong-Bae Park;Ki Baek Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.607-614
    • /
    • 2023
  • Clear overlapping of the bilateral epicondyle and proper separation of the elbow joint are crucial for obtaining accurate lateral general radiographs of the elbow. However, due to the complex anatomical structure of the elbow, achieving optimal positioning is challenging, leading to the need for repeated x-ray examinations. Therefore, the purpose of this study was to investigate the angle of the forearm in patients where accurate lateral images of the elbow joint can't be obtained after vertical incidence using a styrofoam device during elbow joint lateral x-ray imaging. Twenty patients were enrolled in our study following the established protocol. First, a vertical x-ray at an angle of 0° between the forearm and the table was taken (control group). Here, if the lateral image of the elbow joint was deemed inadequate, the forearm angle was adjusted using custom-made styrofoam supports with 5° and 10° inclinations (experimental groups). For the evaluation method, two assessors utilized a 5-point Likert scale to assess the images. The reliability of the assessments was analyzed using Cronbach's alpha coefficient. As a result, patients with inadequate overlap of the bilateral epicondyle and separation of the elbow joint in the initial examination (control group) were able to obtain the best images when setting a 10° angle between the forearm and the table. The subjective evaluation was 1.6 ± 0.8 points at 0°, 2.7 ± 0.8 points at 5°, and 4.4 ± 1.3 points at 10°, respectively. The reliability analysis for the angles of 0°, 5°, and 10° yielded Cronbach's alpha values of 0.867, 0.697, and 0.922, respectively. In conclusion, when it is not possible to obtain accurate images using the conventional position and X-ray beam direction, it is considered that by initially acquiring images with an angle of 10° between the forearm and the table, and gradually decreasing the angle while obtaining images, it would be possible to achieve the optimal image while reducing the number of repeat examinations.

General Radiography Examination Statistical analysis of Patients in Geriatric hospitals (노인요양병원 내원환자의 일반촬영 통계분석)

  • Kim, Kyuhyung;Lee, Junhang;Kim, Youngwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • The purpose of this study is to establish the basic data for the management of the elderly patients aged more than 60 suffering from musculoskeletal disorders in geriatric hospitals. From January, 1 2012 to December 31, 2012, 2,500 patients who were taken the x-ray inspection and were analyzed x-ray order 5,042 cases above spines, upper lower extremities and joints. The elderly age was divided into 3 groups according to Brody elderly statistics. The majority of elderly patients who visited the hospital are exposed to spinal disorders and joint diseases. Shoulder, knee, L-spine examination cases had accounted for more than half the number of total. By age group, the number of the first quarter was most dominant commonly. Second and third quarter was maintaining slightly decrease. The fourth quarter had reduced compared to the first quarter. If the visiting purposes and the disease causes analysis and preventive measures are taken in a study, it is expected to utilize as basic data to make a plan of the education for preventing diseases and elderly behavior planning for geriatric hospitals and to redistribute health care resources of the rural areas efficiently.

A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test (블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구)

  • Park, Jikoon;Kim, Kyotae;Yoon, Inchan;Choi, Ilhong;Jung, Hyungjin;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.389-395
    • /
    • 2013
  • This study intended to investigate the optimum conditions for lumbar test that has the highest level of irradiation conditions among general test sites. To to this, the most widely used irradiation conditions in terms of statistics were set as standards; test groups applied with DMF were selected; tests groups suitable for clinical trials were selected by using suggested patient dose. Blind tests were conducted by 10 specialists and radiologists. The results suggested that under the optimum conditions, the radiation dose reduction of 2.09 mGy, 4.42 mGy and 3.65 mGy can be achieved in forward-backward test, lateral test and 4-direction test, respectively. There is a need of further studies on the optimization of irradiation conditions in accordance with the conditions of patients.

ERUPTION DISTURBANCE ASSOCIATED WITH A SMALL ODONTOMA (작은 치아종으로 인한 맹출 장애)

  • Song, Ji-Hyun;Lee, Kwang-Hee;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.490-497
    • /
    • 2007
  • Odontoma is defined as a benign odontogenic tumor containing enamel, dentin as well as cementum and constitued 22% of all odontogenic tumors. Although the lesions are commonly asymptomatic, they may be discovered routine radiographic examination. Odontomas often cause disturbances in the eruption of teeth such as, impaction or delayed eruption, retention of primary teeth, or abnomalities in the position of the teeth such as tipping or displacement of adjacent teeth. Radiologically, odontomas manifest as a dense radiopaque lesion surrounded by a thin radiotransparent halo. However, in some cases, radiopacity was not quite clear and images of the teeth shadowed very tiny odontomas. And at early development stages of odontoma, calcification remains immature and is difficult to diagnose on radiographs. This suggests that when delayed eruption of the teeth is found, periapical radiographs should be taken to clarify whether any small area of radiopaque material exists. This case report shows tiny odontomas involving an impacted tooth and crowding and we remove the tiny odontoma surgically.

  • PDF