• Title/Summary/Keyword: 인체 무릎 피부

Search Result 5, Processing Time 0.02 seconds

Measurement of Surface Strain on Soft Biological Tissues Using Irregular Grid Pattern (불규칙적인 격자망을 이용한 생체 연조직의 곡면변형률 측정)

  • Lee, Jun Sik;Kim, Ki Hong;Kim, Hyung Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1051-1057
    • /
    • 2013
  • In this study, an automatic surface-strain measurement system called "ASIAS-bio" has been developed. This system can be used even in cases in which it is very difficult to apply a regular grid pattern necessary for measuring surface-strain, such as curved or uneven surfaces; surfaces damaged by corrosion or contamination; or soft materials such as rubber, foam, and biological tissues. This system works independently of the measurement conditions including the material and its surface condition, grid pattern and size, grid marking method, and degree of deformation. A comparison between the strain distributions of the sheet metal parts measured by using this system and those obtained by a commercial system showed that this system was sufficiently reliable. In addition, the deformation of the swine joint capsule and human knee skin was measured by using this system to demonstrate its usefulness.

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

An Exploratory Study of Searching Human Body Segments for Motion Sensors of Smart Sportswear: Focusing on Rowing Motion (동작에 따른 피부변화 분석을 통한 동작센서 부착의 최적위치 탐색: 조정 동작을 중심으로)

  • Han, Bo-Ram;Park, Seonhyung;Cho, Hyun-Seung;Kang, Bokku;Kim, Jin-Sun;Lee, Joohyeon;Kim, Han Sung;Lee, Hae-Dong
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.17-30
    • /
    • 2017
  • Lots of interdisciplinary studies for fusion of high technologes and the other areas of research had been tried in these days. In sports training area, high technologies like a vital sign sensor or an accelerometer were adopted as training tools to improve the performance of the sports players. The purpose of this study is finding the proper locations on the human body for attaching the motion sensors in order to develop a smart sportswear which could be helpful in training players. The rowing was selected as a subject sport as lots of movements of the joint on human body could be seen in rowing motions. The players of rowing could be devided into two weight divisions, the lightweight and the heavyweight. In this study, the change rates of distance between markers on human skin as the players moved were took on the back, the elbow, the hip and the knee area on human body by 3D motion capturing system. The distances between markers and the differences between the lightweight and heavyweight were analyzed. Finally, this study provided the guide lines for designing a motion sensing smart sportswear.

A New Experimental Error Reduction Method for Three-Dimensional Human Motion Analysis

  • Mun, Joung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.459-468
    • /
    • 2001
  • The Average Coordinate Referenee System (ACRS) method is developed to reduce experimental errors in human locomotion analysis. Experimentally measured kinematic data is used to conduct analysis in human modeling, and the model accuracy is directly related to the accuracy of the data. However. the accuracy is questionable due to skin movement. deformation of skeletal structure while in motion and limitations of commercial motion analysis system . In this study. the ACRS method is applied to an optically-tracked segment marker system. although it can be applied to many of the others as well. In the ACRS method, each marker can be treated independently. as the origin of a local coordinate system for its body segment. Errors, inherent in the experimental process. result in different values for the recovered Euler angles at each origin. By employing knowledge of an initial, calibrated segment reference frame, the Euler angles at each marker location can be averaged. minimizing the effect of the skin extension and rotation. Using the developed ACRS methodology the error is reduced when compared to the general Euler angle method commonly applied in motion analysis. If there is no error exist in the experimental gait data. the separation and Penetration distance of the femoraltibial joint using absolute coordinate system is supposed to be zero during one gait cycle. The separation and Penetration distance was ranged up to 18 mm using general Euler angle method and 12 mm using the developed ACRS.

  • PDF

Exploring the Effect of Qihyul-therapy for Recovery of Qi Circulation in Body (인체에서 기혈(氣穴) 순환 회복을 위한 기혈테라피의 효과 탐색)

  • Kim, Yong Pil;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.8 no.2
    • /
    • pp.63-70
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate whether Qihyul-therapy was effective against subjects of bad Qihyul circulation who had narrowed muscles of the buttocks, a distorted body shape, or pain. Methods: Qihyul-therapy used. Results: The muscles of the buttocks remained almost untouched. The elasticity of the muscles restored. The skin tone brightened, and the anal muscle strengthened after Qihyul-therapy. The subject's body was shifted to the right by -7°. The right arm was about 6 cm longer than the left arm. But after correction, the right arm was about 5 cm shorter. The distorted body was almost balanced. After neck and shoulder correction, the distance between the collarbone and neck was 7~10 cm wider. After the pelvic correction, the pain in the buttocks was relieved, and the position of the hip joint returned correctly. The right leg that was turned 45° to the left was corrected, and the length became the same. Subjects had no knees attached, their right knees were up 5 cm above the left, and their ankles bent at an angle of 30 ° relative to the left, but after correction, the knees of the two legs stably attached. The height of the knee became the normal angle. Conclusion: If the Qihyul-therapy, the spine correction Qihyul-exercise and the pelvic correction Qihyul-exercise performed steadily, the deformed body shape restored adequately, and it is useful to prevent and cure related diseases by alleviating the pains.