• Title/Summary/Keyword: 인자대공

Search Result 8, Processing Time 0.027 seconds

A Study on the Detection of Fault Factor in Gear-Integrated Bearing (기어일체형 베어링의 결함인자 검출에 대한 연구)

  • Yeongsik Kang;Ina Yang;Eunjun Lee;Hwajong Jin;Donghyouk Shim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.113-121
    • /
    • 2023
  • High-precision lasers and anti-aircraft radars are the main equipment to protect the Korean Peninsula, and require preemptive maintenance before signs of failure. Of the key components in the drive sector, bearings do not have a fault alarm function. Therefore, the technology for diagnosing defects in bearings before the performance degradation of equipment occurs is becoming more important. In this paper, for the experimental analysis, we measured the acceleration of the four sets of the same lot using acceleration sensors. Through periodic measurements, the factors that changed until the bearing stopped rotating were analyzed. To determine the replacement time, the main factors and threshold values of the bearing signal were analyzed. The error of the theoretical and experimental analysis results of the defect frequency was within 2.8 %, and the validity of the theoretical analysis results could be confirmed. Based on the results, it is possible to remotely transmit trouble alerts to users through the system check function.

A Study on the Properties of Acoustic in Multi-purpose Auditorium Using Remodeling and Computer Simulation (U다목적 문화예술회관의 리모델링시 개선전후의 시뮬레이션 및 음향측정분석에 관한 연구)

  • 손장열;김정중;김용국
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.808-815
    • /
    • 2003
  • 최근에 이르기까지 문화예술회관들이 대중들의 문화적인 욕구에 의하여 많이 건립되었으나 대중들과 음악가와 연주자들을 도외시한 채 건축음향 기획 없이 건립되어진 많은 문화예술회관들이 지방자치시대를 맞이하여 지방재정에 적잖은 부담으로 작용하고 있으며 또한 민영화로 독자적으로 운영을 하지 않으면 안되게 되었다. 이와 같은 경쟁체제에서 많은 문화예술회관들이 음향문제로 많은 어려움을 겪고 있으나 대책은 미미한 실정이다. 본 연구는 U문화예술회관의 대공연장을 중심으로 대공연장의 음향특성을 측정분석하고 최근 6년간의 공연장의 장르별 이용률을 기초 자료로 활용하여 측정 결과를 중심으로 대공연장의 개선방향을 설정하고 음향 시뮬레이션를 통한 음향인자를 (잔향시간 (RT60, EDT), 명료도(C80, D50), LF, 음압레벨) 비교분석 평가하였다. 그리고 설계에 반영 벽체에 음향 보강 반사판을 시설하고 분석하여 리모델링 공사 후 음향특성이 개선됨을 확인할 수 있었으며 벽체에 시공된 반사판의 효능을 입증할 수 있었다.

  • PDF

Analysis Study of Diaphragm Wall by Construction Process of Large Underground Space for Complex Plant Installation (복합플랜트 설치를 위한 지하 대공간 건설 공정별 연속벽체 해석 연구)

  • Kim, Sewon;Park, JunKyung;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.11-19
    • /
    • 2022
  • Underground environmental infrastructure and energy production facilities, which are recognized as avoidable facilities such as landfills, are emerging as an important social issue due to urbanization and economic growth. It is necessary to analyze the stability according to various ground conditions and load conditions for the construction of large-scale underground complex plants. In this paper, horizontal/vertical displacement and stress distribution according to the load condition and construction process were analyzed using finite element analysis (FEM), Based on the analysis results of various conditions, factors to be considered in the detailed design and construction of the underground complex plant were reviewed and the implications on design factors (Intermediate wall installation status, Pre-reinforcing area, etc.) for underground large space construction were derived.

A Study on the Smoke control Design parameter of Large Volume space by Fire Dynamic Simulation (화재 시뮬레이션(FDS)을 이용한 대형공간의 제연 설계인자에 관한 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.237-243
    • /
    • 2018
  • Performance-oriented design has been introduced in fire protection design, and various efforts have been made to minimize the damage caused by fire in the design stage. We conducted a study to provide information for reasonable design factors using a Fire Dynamic Simulation code provided by the NIST on boundary width and amount of supply. This paper shows that using a living-room air-supply system in a large space and dividing the space by a ventilation boundary are the two factors that are considered to have the greatest influence on the design of the living room ventilation. The results show that for performance-based design, the width of the ventilation boundary is designed to be the maximum limit in the initial design. It is judged that reasonable air volume determination should be made through various methods.

Development of Tacho Generator for Application of Anti-aircraft Weapon System (대공무기체계 적용을 위한 타코제너레이터 개발)

  • Byun, Kisik;Park, Jun Young;Cho, Sung-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.174-180
    • /
    • 2020
  • This paper presents the development of a tacho generator that is applicable to a DC motor for anti-aircraft weapon systems. In general, devices such as tacho generators and resolvers are used as feedback devices for controlling DC motors. A tacho generator with a wide operating temperature range was developed, which has robust characteristics against shock loads and vibrations according to the operational characteristics of anti-aircraft weapon systems. The target specifications were set based on the requirements of the tacho generator currently in operation. A rotor coupled to the shaft of the motor and a stator coupled to the housing of the motor were then designed and manufactured. The inductance was 31.0 mH, the terminal resistance was 147.7 ohms, and the rotational measurement factor was satisfactory under both normal operation and operating conditions after the maximum speed for the standard of 9.500 ± 0.475 V/krpm. In addition, the environmental suitability of the applied equipment was confirmed through the rate of change in unit temperature, and it was found that the temperature characteristics were all within 0.03 %/℃.

Soil Moisture Measurements and Correlation Analysis to Understand the Runoff Generation Process for a Bumrunsa Hillslope of Sulmachun Watershed (설마천 범륜사 사면 유출과정의 이해를 위한 실측토양수분 상관도 분석)

  • Kim, Sang-Hyun;Kang, Mi-Jeong;Kwak, Yong-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.5
    • /
    • pp.351-362
    • /
    • 2011
  • The soil moisture measurements and correlation analysis are presented to improve understanding the hydrological process at the hillslope scale. The rainfall events is a main driver of soil moisture variation, and its stochastic characteristic need to be properly treated prior to the correlation analysis between soil moisture measurements. Using field measurements for two designated periods during the late summer and autumn seasons in 2007 obtained from the Bumrunsa hillslope located at the Sulmachun watershed, prewhitened correlation analysis were performed for 8, 14, 7 and 7 relationships representing the vertical, lateral, recharge and return flows, for two designated periods, respectively. The analysis indicated both temporal and spatial variation patterns of hydrological processes, which can be explained by the relative contribution of matrix and macropore flows and the impact of transect topography, respectively.

Technical Index for the Maintenance of Watertightness of the Roof of a Large-Span Membrane Structure (대공간 막 구조물 지붕의 수밀성능 확보를 위한 유지관리 지표 연구)

  • Oh, Sang-Keun;Kim, Dong-Bum;Lee, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.1
    • /
    • pp.51-59
    • /
    • 2011
  • With the increased demand for membrane structures in recent years, there have been many studies of their mechanical properties, to the extent that such structures have become recognized as independent structures with a level of safety and durability comparable to those of other general structures. But in reality, the study for the maintenance of membrane structures has not been as active. In particularly, the study of watertightness from the perspective of maintenance has been very limited. Accordingly, a study on securing watertightness performance and the guidelines for maintenance is necessary. In this study, through a case study of water leakage accidents in membrane structures overseas, causes of leakage were selected from the membrane material itself, joint parts and open door of roof part in membrane structure. The water leakage and deterioration elements were analyzed from those leakage causes. The degree of importance of the water leakage and deterioration index was also designated using the AHP (Analytic Hierarchy Process) method. As a result, the basic technical index was suggested for the maintenance of the roofs of large-span membrane structures to prevent water leakage. This index will be used to make a guideline for the long-term maintenance of the roofs of large-span membrane structures.

Changes of Physical Properties of Soils by Organic Material application (유기성 물질 시용에 따른 농경지 토양물리성 변화 연구)

  • Kim, Lee-Yul;Cho, Hyun-Jun;Han, Kyung-Hwa
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.5
    • /
    • pp.304-314
    • /
    • 2004
  • The objective of this study was to investigate the effect of organic materials (compost, straw, green manure, pig manure, seed production oil cake, and industrial by products including municipal sewage sludge, industrial sewage sludge, leather processing sludge, and alcohol fermentation processing sludge) on physical properties of soils in seven paddy and four upland fields with differential soil textures, sandy loam, loam, or clay loam, etc. The investigated physical parameters were bulk density (BD), air permeability (AP), macroporosity, hardness, shear resistance, frictional resistance, water stability aggregate (WSA), and Middleton's dispersion ratio. Except for coarse sandy loam field with weak structure, a decrease in BD and shear resistance, and an increase in macroporosity and AP in plots with applying organic materials compared to plots without applying organic materials appeared. In upland fields, the positive effect of organic materials on WSA, BD, and air permeability was higher than in paddy fields. The combined plot of NPK and compost had lower BD, hardness, and shear resistance, and higher macroporosity and WSA than plot with compost. Green manure had higher positive effect on physical properties of soils compared to other organic materials and the extent of positive effect had no significant correlation with soil organic matter content. Of industrial byproducts applied in coarse sandy loam soil under upland condition, municipal sewage sludge and pig manure compost had higher effect on increase of WSA than leather processing sludge and alcohol fermentation processing sludge. Unlike WSA, there were no significant differences between industrial byproduct types in other physical properties. in silty clay loam soil under the upland condition, straw had more positive effect on soil physical parameters than hairy vetch and pig manure. Therefore, different organic materials had differently active effect on physical parameters depending on types of soil and land use. Especially, it could be thought that well-decomposed organic materials have the advantage of an increase in organic matter content, while coarse organic materials of an increase in WSA.