• Title/Summary/Keyword: 인대 재건술

Search Result 286, Processing Time 0.028 seconds

Appearance of Meniscus Tear Associated with ACL Rupture - Analysis of Location and Type of Meniscus Tear - (전방 십자인대 파열과 동반된 반월상 연골 파열 양상 - 파열부위 및 형태의 분석 -)

  • Lee, Yeong-Hyun;Nam, Il-Hyun;Moon, Gi-Hyuk;Yun, Ho-Hyun;Kim, Jae-Cheol;Ahn, Gil-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.45-49
    • /
    • 2007
  • Purpose: We analyzed the location and type of meniscus tear associated with ACL rupture in order to estimate and prepare whether the meniscus tear is in a repairable location. Materials and Methods: We reviewed 78 cases who had ACL reconstructive surgery due to ACL rupture. We set the period of acute injury on the basis of under 12 months after trauma. The location and type of meniscus tear was analyzed in accordance with MRI findings and arthroscopic findings. Results: The 50 cases of meniscus tear were detected out of the 78 ACL rupture;32 cases were lateral meniscus tears, 24 were medial meniscus tears and 6 cases were both menisci tears. From a total of 56 meniscus tears, 30 cases were longitudinal tears, 22 cases were red-red zone tears and 35 cases(62%) were posterior horn tears. Conclusion: The most common type of meniscus tear associated with ACL rupture war longitudinal tear at the red-red zone or meniscosynovial junction. Majority of the tears located at that place can be healed with conservative treatment, arthroscopic meniscus suture.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

Analysis of Isometric Position of the Anterior Cruciate Ligament During the Knee Flexion-Extension (무릎 굴신 운동과 전십자 인대의 등장위치 해석)

  • Park J.H.;Son K.;Moon B.Y.;Suh J.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1933-1936
    • /
    • 2005
  • The isometric area of the anterior cruciate ligament was calculated during knee flexion-extension. Flexion-extension motion data of the joint were obtained using Fastrak and a three-dimensional motion measurement system. A total of five subjects were seated on a flat table and the tibia sensor position was measured with the femur fixed on the table. A three-dimensional knee model was constructed using a graphic tool to simulate the knee motion. Twenty seven positions of the tibia region and forty two positions of the femur region were selected and the distances between the determined tibial and femoral points were calculated. Highly isometric areas were found and displayed as three dimensional aspects.

  • PDF

Histopathological Study of Cartilage in the Bone Bruise of the Lateral Femoral Condyle Associated with Anterior Cruciate Ligament Rupture (전방 십자 인대 파열시 손상된 대퇴골 외과 연골의 병리조직학적 연구)

  • Bae, Dae-Kyung;Yoon, Kyoung-Ho;Kim, Hee-Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.154-161
    • /
    • 2005
  • Purpose: to describe the histologic appearance of the type III bone bruise in knees which had sustained an acute anterior cruciate ligament (ACL) rupture. Materials and Method: Twenty-five patients who sustained acute ACL rupture were prospectively enrolled in this study. On MRI, 14 patients demonstrated type III bone bruise on lateral femoral condyle, and 11 patients didn't demonstrated bone bruise. Arthroscopic evaluation and biopsy of the articular cartilage and subchondral bone wert performed before ACL reconstruction. Histologic and immunohistochemical evaluations were done. Results: There was no difference between the bone bruise and control group in the hematoxylin-eosin staining for cell distribution, Masson's trichrome staining for collagen and immunohistochemical staining for type I and type II collagen (p>0.05). But in the safranin-O staining for glycosaminoglycan distribution, the bone bruise group had an evidence of decreased staining at the superficial and middle layers, compared with the control group (p<0.05). We also found fatty change of bone marrow in calcified zone of the bone bruise group with safranin-O staining. Conclusion: We suggest that the type III bone bruise found on MRI indicates a substantial damage to normal articular cartilage homeostasis, and may induce further damage of the articular cartilage.

  • PDF

A study of isometric position of the knee during anterior cruciate ligament reconstruction (전십자 인대 재건시 등장위치에 관한 연구)

  • 박정홍;손권;김광훈;문병영;서정탁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.158-161
    • /
    • 2004
  • The isometric position of the anterior cruciate ligament was calculated during flexion-extension. Flexion-extension motion data of the knee joint were obtained by Fastrak, a three-dimensional motion measurement system. A subject was seated on a flat table and the tibia sensor position was measured with the femur fixed at the table. A three-dimensional knee model was constructed using a graphic tool to simulate the knee motion. Three surgical positions of the femoral tunnel were selected and the distances between the determined tibial tunnel and each femoral tunnel were calculated. The maximum elongation position was found to be in the ten thirty direction of clock.

  • PDF

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

Reconstruction of Anterior Cruciate Ligament in Adolescent (청소년기에 시행한 전방십자인대 재건술)

  • Song Eun Kyoo;Shim Sang Don;Kim Hyung Jong;Kim Hyung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2002
  • Purpose: To evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction and to know the results of physeal injury by transphyseal tunnel in adolescents who had remaining growth potential. Materials and Methods : This study involved 12 patients under 19 years old out of 445 patients, who underwent ACL reconstruction between 1993 and 2001. The mean age at the time of operation was 15.9 $(13.1\~16.9)$ years and fellow-up period was 45.1 $(24\~120.6)$ months in avrarge. Autologous quadrupled hamstring tendon was used as graft in 11 cases and bone-patellar tendon-bone in 1 case. Clinical results were evaluated by Lysholm Knee Scoring Scale, range of motion and return to preinjury sports activities. Radiologic results were evaluated by $Telos^{\circledR}$ device. Bone maturity were analyzed by chronological age, standing height and the width of growth plate in AP and lateral view of knee joint at preoperatively. The growth disturbances were evaluated by measuring femorotibial angle, anatomical and mechanical lateral distal femoral angle, mechanical medial proximal tibial angle and leg length and by comparing those of uninjured site in last follow-up teleoroentgenogram. Results : The mean Lysholm Knee score was 51 $(25\~63)$points preoperatively and 98 $(94\~100)$ points at last follow up. The mean anterior displacement of the tibia by using $Telos^{\circledR}$ device was improved from 13.5 $(6\~27)$ mm to 2.9 $(1\~4)$ mm and there were no significant instabilities of the knee in all cases. There were no leg length discrepancies over 1 cm and no statistically significant abnormal alignment of the knee joint in all cases. Conclusion: ACL reconstruction using transphyseal tunnel for restoring stability and knee function is assumed as a good mettled of treatment without significant leg length discrepancy and abnormal alignment of the knee joint.

  • PDF

Comparison of Clinical Outcomes in ACL Reconstruction using auto-Hamstring Tendon and allo-Tibialis Anterior Tendon (자가슬괵건 및 동종전경골건을 이용한 전방십자인대 재건술 후 임상적 결과의 비교)

  • Kim, Jae-Hwa;Lee, Yoon-Seok;Rhee, Seung-Yong;Chung, Ju-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.104-110
    • /
    • 2007
  • Purpose: The purpose of this study is comparison of clinical outcomes in ACL reconstruction between auto-hamstring tendon and allo-tibialis anterior tendon. Materials and Methods: In this prospective study, we included 60 subjects who underwent ACL reconstruction using 30 hamstring autograft(mainly, national health insurance) and 30 tibialis anterior allograft(including MVA and industrial injuries) between May 2003 and June 2005 by a single surgeon, with a minimum follow-up of 12 months. Outcome measurements were the range of motion, the Lachman test, the IKDC score, the Lysholm score, KT-1000 arthrometer and one-leg hop test. Results: For all the cases, the range of motion was above 135 degrees. The Lachman test, KT-1000 arthrometer and one-leg hop test showed no significant difference between two groups. The IKDC score of auto-hamstring group($87.840{\pm}2.106$) was significantly higher than that of allo-tibialis anterior group($85.273{\pm}2.782$). The Lysholm score of auto-hamstring group($88.067{\pm}2.586$) was also significantly higher than that of allo-tibialis anterior group($85.300{\pm}3.030$). Conclusion: The results of ACL reconstruction using the auto-hamstring tendon and allo-tibialis anterior tendon showed no significant difference in objective items but auto-hamstring group showed better results in subjective scoring. This difference may result from individual factors such as economic problem, secondary gain.

  • PDF

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Arthroscopic Reduction of Irreducible Knee Dislocation - A Case Report - (정복 불가능한 슬관절 탈구의 관절경적 치료)

  • Jeong, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.161-164
    • /
    • 2009
  • Irreducible knee dislocation is a rare injury and often need an open procedure with ligaments reconstruction. This report describes a case of arthroscopic treatment of a patient with traumatic knee dislocation unable to reduce in a closed method. MRI revealed incarceration of the medial collateral ligament and capsule in the medial compartment. And arthroscopic examination confirmed incarcerated medial capsuloligamentous structures which prevented the knee from reduction. Arthroscopic procedure without ligaments reconstruction was complete when the medial condyle was well visualized and the knee reduced. After 4 weeks of immobilization in extension, range of motion exercise and gradual increases in weight bearing was allowed. At the 3- year follow-up, mild laxity was remained but the patient did not have any discomfort of doing ADL activity and showed full range of motion of the knee.

  • PDF