• Title/Summary/Keyword: 인공관절 치환술

Search Result 84, Processing Time 0.02 seconds

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

Comparison of Inpatient Medical Use between Non-specialty and Specialty Hospitals: A Study Focused on Knee Replacement Arthroplasty (전문병원과 비전문병원 입원환자의 의료이용 비교 분석: 인공관절치환술(슬관절)을 대상으로)

  • Mi-Sung Kim;Hyoung-Sun Jeong;Ki-Bong Yoo;Je-Gu Kang;Han-Sol Jang;Kwang-Soo Lee
    • Health Policy and Management
    • /
    • v.34 no.1
    • /
    • pp.78-86
    • /
    • 2024
  • Background: The purpose of this study was to determine the effectiveness of the specialty hospital system by comparing the medical use of inpatients who had artificial joint replacement surgery in specialty hospitals and non-specialty hospitals. Methods: This study utilized 2021-2022 healthcare benefit claims data provided by the Health Insurance Review and Assessment Service. The dependent variable is inpatient medical use which is measured in terms of charges per case and length of stay. The independent variable was whether the hospital was designated as a specialty hospital, and the control variables were patient-level variables (age, gender, insurer type, surgery type, and Charlson comorbidity index) and medical institution-level variables (establishment type, classification, location, number of orthopedic surgeons, and number of nurses). Results: The results of the multiple regression analysis between charges per case and whether a hospital is designated as a specialty hospital showed a statistically significant negative relationship between charges per case and whether a hospital is designated as a specialty hospital. This suggests a significant low in charges per case when a hospital is designated as a specialty hospital compared to a non-specialty hospital, indicating that there is a difference in medical use outcomes between specialty hospitals and non-specialty hospitals inpatients. Conclusion: The practical implications of this study are as follows. First, the criteria for designating specialty hospitals should be alleviated. In our study, the results show that specialty hospitals have significantly lower per-case costs than non-specialty hospitals. Despite the cost-effectiveness of specialty hospitals, the high barriers to be designated for specialty hospitals have gathered the specialty hospitals in metropolitan and major cities. To address the regional imbalance of specialty hospitals, it is believed that ease the criteria for designating specialty hospitals in non-metropolitan areas, such as introducing "semi-specialty hospitals (tentative name)," will lead to a reduction in health disparities between regions and reduce medical costs. Second, it is necessary to determine the appropriateness of the size of hospitals' medical staff. The study found that the number of orthopedic surgeons and nurses varied in charges per case. Therefore, it is believed that appropriately allocating hospital medical staff can maximize the cost-effectiveness of medical services and ultimately reduce medical costs.

Clinical and radiologic study of total knee replacement arthroplasty using Doujet GF bone cement (liquid-powder bone cement containing gentamicin) (Doujet GF 골 시멘트를 사용한 인공 슬관절치환술의 임상적, 방사선적 고찰)

  • Sungwook Choi;Seong-meen Yoon;Joseph Y. Rho;In-seok Son
    • Journal of Medicine and Life Science
    • /
    • v.20 no.2
    • /
    • pp.60-66
    • /
    • 2023
  • Gentamicin-loaded bone cement used in total joint arthroplasty is indispensable, as it provides stability by directly binding the surfaces of implants and bones. Depending on multiple factors, including the material of the bone cement used, common complications, such as aseptic loosening, osteolysis, and infection can occur postoperatively. In clinical practice, Doujet bone cement is easy to handle (pre-packed all-in-one system), and has shown low failure rates and non-inferior results compared with similar available products. We conducted a retrospective comparative study to analyze the clinical and radiological results of each bone cement group to establish the safety and usefulness of Doujet bone cement. From July 2020 to July 2022, we enrolled 198 patients in this study after an average follow-up period of 37 months (range, 6-48 months). In 99 patents, Doujet® bone cement (Injecta, Gunpo, Korea) was used for total knee arthroplasty (TKA), while Refobacin® bone cement (Biomet, Warsaw, IN, USA) was used in 99 patients. The average range of motion (ROM) of the knee increased by 2.4° (from 127.0° preoperatively to 129.4° postoperatively) in the Doujet group, and by 0.1° (from 128.7° to 128.8°) in the Refobacin group (P=0.701). The Western Ontario and McMaster Universities (WOMAC) osteoarthritis index scores decreased from 44.1 to 7.8 in the Doujet group, and from 44.2 to 6.3 in the Refobacin group (P=0.162). Complications, such as osteolysis or post-operative wound infection, did not occur in more than two cases in both groups. The WOMAC and ROM of the knee in both groups had no clinical differences. Both Doujet and Refobacin similarly showed low complication rates after TKA.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.