• Title/Summary/Keyword: 이화여대

Search Result 103, Processing Time 0.019 seconds

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use Based on Measurements of Sample Office Building (표본건물 계측에 의한 업무시설에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Lim, Han-Young;Lim, Su-Hyun;Jin, Hye-Sun;Kim, Sung-Im;Lee, Soo-Jin;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.8
    • /
    • pp.19-27
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and $CO_2$ emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 19 sample office buildings in Seoul. In addition, the estimated site EUIs by end use were compared to the U.S. Commercial Buildings Energy Consumption Survey (CBECS) 2012 data. Average site EUIs by end use were found to be in the order of electric appliance (typical floors) > heating > cooling > lighting > air movement > domestic hot water > vertical transportation > city water supply. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the CBECS 2012 data, it was found that the site EUIs were similar for heating, cooling, domestic hot water, and electric appliance, etc., but slightly different for lighting and air movement. The number of sample office buildings will continue to increase until 2020 (total number of samples 85) and intensities data by end use will be continuously updated through continuous collection of measurement data.

여류과학자 - 이화여자대학교 물리학과 모혜정 교수

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.30 no.2 s.333
    • /
    • pp.62-63
    • /
    • 1997
  • 대통령 직속의 국가과학기술자문위원중 유일한 여성위원으로 활약하고 있는 이화여대 물리학과 모혜정교수. 모교수는 이화여대 재직중 공과대학을 설립하는데 주도적 역할을 했으며 6년동안 자연과학대학장과 대학원장을 맡아 지도력과 행정력을 발휘했다. 모교수는 남편인 서울대 물리학과 장회익교수와 함께 과학가문을 이루고 있다.

  • PDF

연구실탐방 - 이화여대 고체화학연구실

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.30 no.5 s.336
    • /
    • pp.26-27
    • /
    • 1997
  • 국내 최고의 첨단연구장비를 갖춘 이화여대 고체화학연구실은 6곳의 실험실에서 신소재 합성을 위해 저온에서부터 2천~3천도가 넘는 고온가열실험을 계속하고 있다. 이 연구소는 96년도 노벨상 수상 분야인 C60연구에 착수, C60을 합성하여 요오드를 도핑시킴으로써 I2C60을 만드는데 성공하여 미국 학술지에 소개되기도 했다.

  • PDF