• Title/Summary/Keyword: 이중 임피던스 선로

Search Result 44, Processing Time 0.021 seconds

Omnidirectional Circularly Polarized Antenna Using Zeroth-Order Resonance (영차 공진을 이용한 전방향성 원형 편파 안테나)

  • Park, Byung-Chul;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.806-812
    • /
    • 2009
  • In this paper, the omnidirectional circularly polarized(CP) antenna using arc-shaped mushroom structure with curved branch is proposed. To obtain a vertical polarization and an omnidirectional radiation pattern, the CP antenna uses zeroth-order resonance(ZOR) mode of composite right and left handed(CRLH) transmission line. The horizontal polarization is achieved by the curved branches. Also, the spacing between curved branch and arc-shaped mushroom structure gives the $90^{\circ}$ phase difference between vortical and horizontal polarization. The proposed antenna, therefore, has an omnidirectional CP radiation pattern In the azimuthal plane. The electrical size of the proposed antenna is reduced by 38%, compared with that of the previously presented omnidirectional CP antenna. In addition, the CP antenna is simply designed without $90^{\circ}$ phase shifter and dual feed line. The proposed antenna uses a Bazooka balun for good impedance matching and radiation pattern. To improve 3 dB axial ratio in XY plane, the designed antenna is optimized. After optimization, the measured 3 dB axial ratio in XY plane is observed in $86{\sim}282^{\circ}$.

Characteristics of High Efficiency Wideband Microstrip Band Pass Filter (고효율 광대역 마이크로스트립 대역통과필터 특성)

  • Lee, Young-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.636-644
    • /
    • 2009
  • This paper presents a compact, low insertion loss, sharp rejection and wide band microstrip band pass filter that is composed rectangular loop resonator and step-impedance-open-stub(SIOS) for wireless data communication. The SIOS can be reduce length about 30% more than general $0.25{\lambda}$ stub. And the stub can the advantage of tuning impedance magnitude. In order to demonstrate agrement of this paper prove, the optimized wide band pass filters are realized and experimented. A transmission line model used to calculate the frequency response of the new filters shows good agreement with measurements. The filter has 3dB fractional bandwith of 52.5%(3.267GHz), an insertion loss of better than 0.33dB from 4.587GHz to 7.854GHz, and two rejection of greater than 30dB within 221MHz$(4.366GHz{\sim}4.587GHz)$ at low frequency band, 181MHz$(7.854GHz{\sim}8.035GHz)$ at high frequency band. Maximum rejection characteristics of the filter are -54dB at low frequency and -60dB at high frequency.

Dual Band-notched Monopole Antenna for 2.4 GHz WLAN and UWB Applications (이중대역 저지특성을 가지는 2.4 GHz WLAN 및 UWB 겸용 모노폴 안테나)

  • Lee, Ki-yong;Lee, Young-soon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.2
    • /
    • pp.193-199
    • /
    • 2017
  • In the paper, a dual band-notched monopole antenna is proposed for 2.4 GHz WLAN (2.4 ~ 2.484 GHz) and UWB (3.1 ~ 10.6 GHz) applications. The 3.5 GHz WiMAX band notched characteristic is achived by a pair of L-shaped slots instead of the previous U-shaped slot on the center of the radiating patch, whereas the 7.5 GHz band notched characteristic is achived by C-shaped strip resonator placed near to the microstrip feed line. The measured impedance bandwidth (${\mid}S_{11}{\mid}{\leq}-10dB$) is 8.62 GHz (2.38 ~ 11 GHz) which is sufficient to cover 2.4 GHz WLAN and UWB band, while measured band-notched bandwidths for 3.5 GHz WiMAX and 7.5 GHz bnad are 1.13 GHz (3.15 ~ 4.28 GHz) and 800 MHz (7.2 ~ 8 GHz) respectively. In particular, it has been observed that antenna has a good omnidirectional radiation patterns and higher gain of 2.51 ~ 6.81 dBi over the entire frequency band of interest.

A Study on Fault Characteristics of Wind Power in Distribution Feeders (풍력발전(DFIG)의 고압배전선로의 사고특성 해석에 관한 연구)

  • Kim, So-Hee;Kim, Byung-Ki;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1288-1295
    • /
    • 2012
  • Korea Ministry of Knowledge Economy has estimated that wind power (WP) will be occupied 37% in 2020 and 42% in 2030 of the new energy sources, and also green energies such as photovoltaic (PV) and WP are expected to be interconnected with the distribution system because of Renewable Portfolio Standard (RPS) starting from 2012. However, when a large scale wind power plant (over 3[MW]) is connected to the traditional distribution system, protective devices (mainly OCR and OCGR of re-closer) will be occurred mal-function problems due to changed fault currents it be caused by Wye-grounded/Delta winding of interconnection transformer and %impedance of WP's turbine. Therefore, when Double-Fed Induction Generator (DFIG) of typical WP's Generator is connected into distribution system, this paper deals with analysis three-phase short, line to line short and a single line ground faults current by using the symmetrical components of fault analysis and PSCAD/EMTDC modeling.