• Title/Summary/Keyword: 이중 스캔

Search Result 61, Processing Time 0.03 seconds

Evaluation of Internal Defect of Composite Laminates Using A Novel Hybrid Laser Generation/Air-Coupled Detection Ultrasonic System (레이저 발생 초음파와 공기 정합 수신 탐촉자를 이용한 복합재료 적층판의 내부 박리 결함 평가)

  • Lee, Joon-Hyun;Lee, Seung-Joon;Byun, Joon-Hyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • Ultrasonic C-scan technique is one of very popular techniques being used for detection of flaws in polymer matrix composite(PMC). However, the application of this technique is very limited for evaluation of defects in PMC fabricated by the automated fiber placement process. The purpose of this study is to develop a novel ultrasonic hybrid system based on nondestructive and non-contact ultrasonic techniques for evaluation of delamination in carbon/epoxy and carbon/PPS composite laminates. It was shown that the newly developed ultrasonic hybrid system based on dual air-coupled pitch-catch technique with ultrasonic scattering reflection concept could provide excellent image with higher resolution of delamination in PMC compared with the conventional pitch-catch method. It is expected that this ultrasonic hybrid technique can be applied for on-line inspection of flaws in PMC during the fabrication process.

The Study for the Reconstruction of two objects using the Stereo X-ray Inspection System (스테레오 X-선 검색장치를 이용한 이중물체 형상복원 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Park, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4152-4158
    • /
    • 2012
  • The Stereo X-ray inspection system is designed for effectively providing the additional information of objects than the conventional inspection system that offers only 2D cross-section of objects. We studied the geometric improvement of the stereo X-ray inspection system, the stereo matching algorithm of the single object using the edge and the volume reconstruction method for the inspected object. In this paper, we conduct a matching algorithm to find the correspondences between the images and reconstruct 3-D shapes of real objects using the stereo X-ray images. Also, we apply a new 3D reconstruction algorithm for the discrimination of two objects. For the separation of the overlapping objects, we calculate the vector of the object and divide inner and outer voxel of objects. And for the elimination of the overlapping area, we study the reconstruct 3D shapes using the threshold based Z-axis. The experimental results show that the proposed technique can enhance the accuracy of stereo matching and give more efficient visualization for overlap objects in the restricted environment.

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.

Usefulness of Three-phasic Bone Scan in Young Male Patients Suspected of Post-traumatic Reflex Sympathetic Dystrophy Syndrome (외상후 교감신경 이영양증이 의심되는 젊은 남자 환자들에서 삼상 골스캔의 유용성)

  • Lee, Won-Woo;Kim, Tae-Uk;Kim, Tae-Hoon;Jung, Cheoul-Yun;Moon, Jin-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.52-60
    • /
    • 2001
  • Purpose: In young male patients who suffered several kinds of trauma with subsequent suspicious reflex sympathetic dystrophy syndrome, we performed three-phasic bone scan in order to investigate its usefulness. Materials and Methods: Patients with narrow range of age (21-25. mean $22.8{\pm}1.3$, all male) were included with suspicious reflex sympathetic dystrophy syndrome of 12 feet and 5 hands. Only one was bilateral feet case and 16 were ipsilateral (Rt:13, Lt:3). The etiologic traumas were 4 fractures, 4 sprains, 3 blunt trauma, 2 cellulitis, 1 tendon tear, 1 crush injury, 1 overexercise, and 1 unknown. Radiologically 3 showed osteoporotic changes. Three-phasic bone scans were performed $21.2{\pm}7.3wks$ after trauma. Results: According to symptom complex, confirmatory reflex sympathetic dystrophy syndrome 4 cases and suspicious 13 were analyzed. All confirmatory cases (100%) showed increased uptake at delay phase with periarticular accentuation. Of confirmatory 4 cases, 2 showed increased uptake in all three phases (perfusion: P, blood pool: B, and delay: D), and other 2 revealed decreased P but, both increased B and D. Of suspicious 13 cases, 9(69.2%) had increased D (4 periarticular and 5 focal), 2 decreased D, and 2 symmetric D. In 12 foot cases, so-called weight hearing patterns - increased contralateral sole at P and B - were revealed in 7(58.3%). Conclusion: Diffuse periarticular increased uptake at delay phase of three-phasic bone scan was a compatible finding to reflex sympathetic dystrophy syndrome in young male patients whose symptom complex strongly designated post traumatic reflex sympathetic dystrophy syndrome.

  • PDF

Dual Modulation Driving for Poly-Si TFT Active Matrix OLED Displays (다결정 실리콘 박막 트랜지스터 Active Matrix OLED 디스플레이를 위한 이중 변조 구동)

  • 김재근;정주영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.17-22
    • /
    • 2004
  • We developed a new ANGLED display driving method which used both amplitude and pulse width modulation. For pulse width modulation, we divided a picture frame time into S sub-frames. For amplitude modulation, we used three OLED luminance(or current) levels which were controlled by TFT's gate voltages. By combining these two modulation methods, we obtained 35(=243) grey levels. And we designed a new data electrode driving circuit block with two shift registers without using DAC's. To verify the feasibility, we simulated the key circuit components by HSpice with TFT parameters extracted from current-voltage characteristics of 6${\mu}{\textrm}{m}$ channel length polysilicon TFT's. From the simulation results, we found that 320${\times}$240, dual scan, 243 grey level AMOLED display can be designed with this method.

Bone Mineral Density Measurement of Rats Using Dual-energy X-ray Absorptiometry: Precision of In Vivo Measurements for Various Skeletal Sites with or without Repositioning (쥐에서 이중에너지 방사선 흡수법을 이용한 골밀도의 측정: 다양한 골부위에서 재위치 여부에 따른 생체내 측정의 정밀도)

  • Oh, Dong-Hyun;Jung, Jae-Ho;Woo, Sang-Keun;Cheon, Gi-Jeong;Kim, Byung-Il;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Purpose: Bone mineral density (BMD) measurements need to be precise enough to be capable of detecting small changes in bone mass of rats. Using a regular dual-energy X-ray absorptiometry (DXA), we measured many BMD of various skeletal sites in rats to examine precision of DXA in relation to the repositioning on the bones of rats. Materials and Methods: Using DXA and small animal software, scans were performed 4 times in all 12 male rats without repositioning (Group 1a). Another four scans for 6 of 12 rats were done with repositioning between scans (Group 2). Customized regions of interest (ROIs), encapsulate the right hind limb, L1-4, skull and pelvic bones were drawn at each measurement. The precision of the measurements was evaluated by measuring the coefficient of variation (CV) of four measurements of BMD at each skeletal site of all rats with or without repositioning. Significance of differences between group 1b (six rats out of group 1a, which were come under group 2) and group2 were evaluated with Wilcoxon Signed Rank Sum Test. Results: CVs obtained at different skeletal sites of all measurements in Group 1b and 2. It was $3.51{\pm}1.20$, $ 2.62{\pm}1.20$ for the hindlimb (p=0.173), $3.83{\pm}2.02$, $4.59{\pm}2.02$ for L1-4 (p=0.600), $3.73{\pm}1.87$, $1.53{\pm}0.89$ for skull (p=0.046), and $2.92{\pm}0.60$, $1.45{\pm}0.60$ for pelvic bones (p=0.075). Conclusion: Our study demonstrates that the DXA technique has the precision necessary when used to assess BMD for various skeletal sites in rats regardless of repositioning.

Radioaerosol Scan Manifestations of Diffuse Panbronchiolitis (미만성 세기관지염의 연무흡입 폐환기스캔 소견)

  • Kim, Hak-Hee;Choi, Byung-Gil;Bahk, Yong-Whee;Chung, Soo-Kyo;Park, Seog-Hee;Shin, Kyung-Sub;Park, Sung-Hak
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.192-199
    • /
    • 1994
  • Diffuse pahbronchiolitis(DPB) is a relatively new, chronic, nonspecific, inflammatory disease of the lung that typically involves the airways in the "transitional" zone of the lung. Clinically, DPB strongly resembles chronic obstructive pulmonary disease (COPD) and the distinction between the two is crucial because the former is often fatal, requiring different therapeutic strategies. This study was prospectively carried out to assess diagnostic usefulness of radioaerosol scan(RAS) in DPB. RAS findings were analyzed with respect to the location and extent of abnormal aerosol deposition in the lung divided into the central, intermediary, and transitional airways and the peripheral airspaces. RAS showed mottled aerosol deposits characteristically in the transitional and intermediary airways with peripheral airspace defects. Such a deposition pattern contrasted sharply with central aerosol deposition of COPD. In conclusion, RAS appears to be a convenient, noninvasive, and useful diagnostic method of DPB.

  • PDF

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

QR Code Based Mobile Dual Transmission OTP System (QR 코드를 이용한 모바일 이중 전송 OTP 시스템)

  • Seo, Se Hyeon;Choi, Chang Yeol;Lee, Goo Yeon;Choi, Hwang Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.5
    • /
    • pp.377-384
    • /
    • 2013
  • In order to improve the security strength in the password based user authentication, in which the security vulnerability is increased while the same password is repeatedly used, the OTP(One-Time Password) system has been introduced. In the OTP systems, however, the user account information and OTP value may be hacked if the user PC is infected by the malicious codes, because the user types the OTP value, which is generated by the mobile device synchronized with the server, directly onto the user PC. In this paper, we propose a new method, called DTOTP(Dual Transmission OTP), to solve this security problem. The DTOTP system is an improved two-factor authentication method by using the dual transmission, in which the user performs the server authentication by typing the user account and password information onto the PC, and then for the OTP authentication the mobile device scans the QR code displayed on the PC and the OTP value is sent to the server directly. The proposed system provides more improved security strength than that of the existing OTP system, and also can adopt the existing OTP algorithm without any modification. As a result, the proposed system can be safely applied to various security services such like banking, portal, and game services.

Unix Kernel Back-door Detection using System Call Table (시스템 콜 테이블에 기반한 유닉스 커널 백도어 탐지)

  • 박인성;송병욱;김홍철;장희진;김상욱;이병권;전완근
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 2001.11a
    • /
    • pp.277-280
    • /
    • 2001
  • 기존 시스템 취약성 공격이나 스캔 공격도구들로부터 최근에는 방화벽이나 기타 보안 시스템을 우회하기 위한 보다 진보된 공격 도구들이 나타났다. 이중 가장 심각한 것이 커널 백도어인데 이는 기존의 사용자 레벨에서가 아닌 커널레벨에서 수행되는 특징을 가진다. 이러한 커널 백도어는 기존의 탐지기술로는 탐지가 불가능하며 현재 피해사례도 정확히 파악되지 않아 그 피해는 더욱 크다 하겠다. 이에 본 논문에서는 현재 배포되어 있는 커널 백도어를 분석하고 기존의 커널 백도어 탐지 기술과 이의 문제점을 해결하는 새로운 커널 백도어 탐지 모델과 구현 방안을 제시한다.

  • PDF