Transactions of the Korean Society of Mechanical Engineers B
/
v.20
no.10
/
pp.3313-3321
/
1996
A fundamental study in cooling and solidification process focused on ice storage was performed, including the interesting phenomena of density inversion, supercooling and dendritic ice. A numerical study was performed for natural convection and ice formation in the cooling and freezing processes with supercooling in a space between double cylinders. When water was cooled under the freezing point by a cooling wall in a cavity, solidification was not started at once, but a subcooled region was formed near the wall. Especially, when the cooling rate was low, subcooled region extended to a wide area. However, after a few minutes, supercooling is released by some triggers. Dendritic ice is suddenly formed within a subcooled region, and a dense ice layer begins to be developed from the cooling wall. Due to the difficulties, most previous studies on solidification process with numerical methods had not treated the supercooling phenomena, i.e. the case considering only the growth of dense ice. In this study, natural convection and ice formation considering existence of supercooling and dendritic ice were analyzed numerically with using finite difference method and boundary fixing method. The results of numerical analysis were well compared with the experimental results.
Proceedings of the Korean Nuclear Society Conference
/
1996.05b
/
pp.385-390
/
1996
영광 3&4호기의 부분충수운전시 정지냉각계통 최소유량의 감소에 따른 영향을 노심의 잔열제거 능력 및 저압안전주입펌프의 성능 측면에서 분석하였다. 정지냉각계통 성능해석용 전산코드인 KDESCENT를 수정하여 사용하였으며 보수적인 초기조건 및 가정을 사용하였다. 분석결과 부분충수 운전동안 원자로냉각재의 최고 허용온도를 작업자의 접근을 위한 설계온도인 140 ℉로 설정할 경우 원자로 정지후 4일 시점에서 이를 만족할 수 있는 정지냉각계통의 최소유량은 실제값으로 3000 gpm(계측기의 오차포함 3440 gpm)임을 알 수가 있었다. 이 유량은 붕산희석이나 성층화, 저압안전 주입펌프의 성능 측면에서도 허용가능한 값이다.
Proceedings of the Korean Institute of Industrial Safety Conference
/
2000.11a
/
pp.118-123
/
2000
화재에 대한 소화방법으로서는 점화원의 냉각, 산화제 농도의 감소에 의한 화염의 질식 및 제거소화와 부촉매를 이용한 소화법이 있다. 이중 냉각소화방법은 주로 물을 사용하여 화재를 진압하고 있으나, 유류화재와 전기화재 등에서는 물보다 할론소화약제가 효과적으로 사용되어 왔다. 그러나 할론 등 CFC 계통의 소화약제는 환경오염물질을 내포하며, 지구온난화지수와 오존파괴지수 등이 높아 전세계적으로 그 사용이 중단되고 있다. 이에 대한 대체 기술의 하나로 최근에 관심이 고조되기 시작한 소화기술은 분무 노즐을 이용한 미세물분무(water mist) 소화설비이다.(중략)
Proceedings of the Korean Society of Precision Engineering Conference
/
1997.04a
/
pp.239-243
/
1997
The heat generation is the most important problem in the motor integrated spindle. Double cooling jacket in necessary to reduce the thermal displacement and to get the stable temperature disribution for the housing. In this study, the effects of temperature distribution and thermal displacement for the spindle system according to the variation of cooling oil flow rate are investigated experimentally on the motor-integrated spindle with double cooling jacket system. The experimental spindel system is composed with the angular contact steel ball bearings, oil-air lubrication, air or oil jacket cooling system.
Transactions of the Korean Society of Mechanical Engineers A
/
v.34
no.9
/
pp.1217-1225
/
2010
The possibility of a sodium-water reaction occurring in a conventional single-wall-tube steam generator in an SFR is a major problem. To improve the reliability of a steam generator, a double-wall-tube steam generator that can reduce the possibility of the occurrence of a sodium-water reaction is being developed. Current developments are focusing on improving the heat-transfer capability of a double-wall tube; further, the development of a leak-detection method to detect the occurrence of a sodium-water reaction during the reactor operation is also underway. In this study, new concepts, which will solve the above-mentioned problems, have been developed. Accordingly, a double-wall tube has been designed, fabricated, and mechanically tested for the purpose.
Proceedings of the Korean Society for Bio-Environment Control Conference
/
1999.11a
/
pp.164-168
/
1999
온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)
MIRIS 우주관측카메라는 과학기술위성 3호의 주탑재체로서 $0.8{\sim}2.0{\mu}m$의 근적외선영역에서 우주배경복사와 우리은하 평면의 Pa-$\alpha$ survey 관측을 목적으로 한다. 이러한 임무를 수행하기 위해 MIRIS 우주관측카메라에는 MCT(HgCdTe) IR 검출기가 사용되고 6개의 필터를 장착할 수 있는 필터휠이 설계되었으며, 열잡음을 줄이고 원하는 SNR을 얻기 위해 모두 100K 이하로 냉각이 요구된다. 효과적인 냉각 및 저온유지를 위해서 외부의 열을 1차적으로 차단하는 Cryostat 외부용기와 100K 이하로 냉각되는 내부 Cold Box의 이중구조를 가지는 Dewar가 설계 되었다. 내부 Cold Box의 냉각은 소형 stirling cooler로 이루어지고 외부의 열 유입량이 Cooler의 냉각용량을 넘지 않도록 설계하였다. Cryostat 외부용기는 radiation cooling으로 냉각되어 200K 이하의 온도를 유지하며 내부 Cold Box로의 열유입을 최소화하기 위해 GFRP(Glass Fiber Reinforced Plastic) 단열 지지대와 MLI(Multi Layer Insulation)가 사용된다. 또한 100K으로 냉각시 필터고정부와 Cold Box 구조에서 일어날 수 있는 구조적인 피로도를 줄이고 열변형에 의한 문제를 방지하기 위한 고려가 설계에 포함되었다. FM(Flight Model)은 고진공 환경의 우주공간에서 문제가 발생하지 않도록 설계되었다. 또한 EQM 진동시험결과를 토대로 발사환경에서 발생하는 강한 진동을 견딜 수 있도록 FEM(Finite Elements Method) 구조해석을 통하여 필터고정부에 flexible structure 설계와 완충제를 추가하고 필터휠 구동부와 harness 고정부 및 cooler 지지부를 비롯한 전체 구조물에서 충분히 진동을 극복할 수 있도록 설계하였다.
Proceedings of the Korean Vacuum Society Conference
/
2010.08a
/
pp.11-11
/
2010
고도의 진공 환경을 요구하는 반도체 생산 라인에 적용되는 고진공 펌프는 주로 복합 분자펌프와 크라이오 펌프가 사용되고 있다. 이 중 크라이오 펌프는 극저온으로 냉각되는 냉각판에 기체 분자를 응축 또는 흡착시켜 기체를 제거하는 방식으로 복합 분자 펌프로 무게가 가볍고 증발 온도가 낮은 네온, 수소, 헬륨 기체 제거에 장점이 있다. 본 연구에서는 현재 상용화된 크라이오 펌프에 적용되는 GM 극저온 냉동기를 대체하기 위한 2단 GM형 맥동관 냉동기를 개발하여 기초 성능 시험을 수행하였다. 1단과 2단 모두 U-자형 형상으로 제작되었으며, 압력과 질량 유동 사이의 위상 조절을 위하여 오리피스 밸브와 이중 유입 밸브를 사용하였다. 개발된 맥동관 냉동기의 냉각 성능 목표는 1단(80 K)과 2단(20 K)에서 각각 45 W와 5 W이다. 기초 시험에서는 위상 조절용 밸브들의 개도와 작동 조건에 대한 냉각 특성과 부하 특성 시험을 수행하였다. 특히, 본 연구에서는 로터리 밸브 및 위상 조절 기구의 배치로 인해 고온부 형상이 복잡한 맥동관 냉동기를 크라이오 펌프로의 적용 편의성을 위하여 고온부 외형 구조를 단순화하였으며, 개발된 맥동관 냉동기와 기존에 크라이오 펌프에 적용되는 GM 극저온 냉동기를 비교, 고찰하였다.
Magazine of the Korean Society of Agricultural Engineers
/
v.36
no.3
/
pp.113-121
/
1994
Since it is difficult to expect the normal production of plants in greenhouses during hot summer season in Korea, certain provisions on the control of extreme environmental factors in summer should be considered for the year-round cultivation in greenhouses. This study was carried out to find a method to suppress the temperature rising of nutrient solution by cooling, which is able to contribute to the improvement of the plant growth environment in hydroponic greenhouse during hot summer season. A mechanical cooling system using the counter flow type with double pipe was developed for cooling the nutrient solution efficiently. Also the heat transfer characteristics of the system was analysed experimentally and theoretically, and compared with the existing cooling systems of nutrient solution. The cooling capacities of three different Systems, which used polyethylene tube in solution tank, stainless tube in solution tank, and the counter flow type with double pipe, were evaluated. The performance of each cooling system was about 41 %, 70% and 81 % of design cooling load in hydroponic greenhouse of 1 ,000m$^2$ on the conditions that the flow rate of ground water was 2m$^3$/hr and the temperature difference between two liquids was 10 ˚C According to the results analysed as above, the cooling system was found to have a satisfactory cooling capability for regions where ground water supply is available. Fer the other regions where ground water supply is restricted, more efficient cooling System should be developed.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.