• Title/Summary/Keyword: 이중관

Search Result 524, Processing Time 0.031 seconds

Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery (폐용제 회수용 이중관형 열교환기 특성 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • This study describes to analyze the heat transfer characteristics of waste solvent recovery system using a double pipe heat exchanger heating solvent by the hot oil. The solvent recovery system consists of the feeding pump, the double pipe heat exchanger, the vacuum spray chamber, and the condenser. A double pipe heat exchanger consists of the first section to conduct the heating of solvent to the thermal saturated point and the second section to evaporate the saturated solvent. The heat transfer area for vaporization of water, benzene and alkylbenzene was predicted by the heat balance modelling and experimentally measured from the temperature distribution as a function of solvent flow rate and heating temperature. The required heat transfer area for vaporization was increased with increasing solvent flow rates and with decreasing heating temperatures due to decreased quantity of transferred heat per the unit area. Theoretical modelling of the heat transfer area for solvents vaporization in the pipe showed good agreement with experimental results. Results showed to be suitable for the waste solvent recovery using a double pipe heat exchanger.

  • PDF

Tracheal Rupture Following Double-lumen Endotracheal Tube Intubation -One Case Report- (이중관 기관 삽관후 발생된 기관파열 - 1례 보고 -)

  • 박승일;원준호;이종국
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.765-767
    • /
    • 1999
  • Tracheobronchial rupture following tracheal intubation is a rare complication. We experienced a case of tracheal rupture following double-lumen endotracheal tube intubation. A 76 year old female was admitted due to coughing and chest discomfort. The operation was performed with the diagnosis of congenital broncho esophageal fistula. During the operation, accidently the main trachea was ruptured longitudinally. There was no history of surgical trauma. The ruptured trachea was repaired with prolene and monofilament absorbable sutures. The cause of tracheal rupture was suspected overinflation of the cuff. The patient was discharged from the hospital without any significant complications.

  • PDF

Turbulent Flow and Heat Transfer in Concentric Annuli Depending on Position of Wall Roughness (벽면거칠기위치에 따른 이중동심관내의 난류유동과 열전달)

  • 안수환;손유식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.136-143
    • /
    • 1997
  • 직경 비가 0.56인 이중동심관에 내외측모두 매끈한 벽면, 벽면 거칠기를 안측, 외측, 그리고 양측 모두의 4경우에 대한 난류 유동과 열전달특성을 실험과 이론으로 연구하였다. 시간평균속도분포, 마찰계수, 그리고 최대 속도 지점과 전단응력이 0인 지점들을 피토튜브와 X형 열선 풍속계로 측정하였다. 이중동심관내에서 4가지 경우에 따른 사각돌출형 거칠기효과가 난류 유동과 열전달에 미치는 영향을 수정난류모델을 기초로 하여 연구하였다. 직경비, 거칠기 위치, 레이놀즈수, 그리고 프란틀수 등의 여러 변수에 의해서 난류 유동과 열전달을 고찰하였다. 본 연구는 전체적 효율 측면에서 유리하게 열전달율을 향상시킬수 있는 거칠기 구조를 밝혔다.

  • PDF

A Study on the Reduction of HC and Heat Characteristics of the Dual Pipe Exhaust Manifold (이중관 배기메니폴드의 HC저감효과 및 열특성에 관한 연구)

  • 박경석;허형석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.103-111
    • /
    • 2001
  • During cold-start period, the reduction of exhaust emissions is a challenging task. To decrease harmful gaseous substances such as HC, it is necessary to realize a fast catalyst warm-up. In this study, the performance of dual pipe exhaust system have been carried out through different test mode. From measurement of gas temperature and HC concentration, the following conclusions were derived ; 1) Compared with single pipe, dual pipe exhaust system remarkably increase temperature of exhaust gas going through M.C.C(Main Catalytic Converter). 2) W.C.C.(Warm-up Catalytic Converter) also decreases HC emission. To reduce HC emission, it is helpful to use W.C.C. as well as dual pipe exhaust system. 3) Using finite element method, it is shown that inner parts have much higher distribution of temperature than outer parts.

  • PDF

The Study of Water Hammer in Polybutylene Double Piping System (폴리부틸렌 이중관에서의 워터 햄머 현상에 관한 연구)

  • Kim, Yong-Bong;Yang, Chan-Mo;Lee, Yong-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.511-516
    • /
    • 2005
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening polybutylene double piping system with header. Experiments were conducted under the following conditions: initial pressure $1{\sim}5$ bar, flow velocity $0.5{\sim}3.0$ m/s and water temperature $25^{\circ}C$.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

The Study of Water Hammer in Polybutylene Double Piping System (폴리부틸렌 이중관에서의 수격 현상에 관한 연구)

  • Lee, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.380-385
    • /
    • 2009
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening polybutylene double piping system with header. Experiments were conducted under the following conditions: initial pressure $0.1{\sim}0.5$ MFa, flow velocity $0.5{\sim}3.0$ m/s and water temperature $25^{\circ}C$.