• Title/Summary/Keyword: 이용흠

Search Result 476, Processing Time 0.028 seconds

Clinical Assessment of Warm Acupuncture Therapy System Using HF Time-varying Magnetic Field (고주파 자기장을 이용한 온침 치료시스템의 임상 평가)

  • Lee, Su-Yong;Byeon, Sang-Jun;Choi, Ye-Bin;Kim, Jin-Ju;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • Objectives : The aim of this paper is to develop acupuncture needle heating system by utilizing the new method which uses high frequency(HF) time-varying magnetic field. Also, it is possible to make an assessment for reliability and clinical significance of the system. Methods : We designed the system with solenoid coils for generation of HF time-varying magnetic field that oscillates at 150 kHz. Acupuncture needles are quickly magnetized and heated by 150 kHz. We assessed clinical significance of system, such as body temperature, pressure pulse waveform. Results : Temperature of acupuncture needle increased up to 60 degree. In the result for clinical significance of system, in case of manual acupuncture stimulation(MAS), body temperature change was $0.373^{\circ}C{\pm}0.224$(p<0.05), rate of pulse energy change increased about 7.6%. In case of warm acupuncture stimulation(WAS), body temperature change was $0.645^{\circ}C{\pm}0.281$(p<0.05), rate of pulse energy change remarkably increased about 35.9%. Conclusions : We confirm that the system is able to be applied clinically to various warm acupuncture needle therapy in the area of oriental medicine.

Analysis of Meridian Energy and its Change Pattern with Time using Measurement of Skin-Capacitance on Source Points (체표 캐패시턴스 측정 방식을 이용한 체표 경락.경혈 에너지 변화 분석)

  • Kim, Soo-Byung;Kwon, Sun-Min;Myoung, Hyoun-Seok;Lee, Kyoung-Joung;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.3
    • /
    • pp.1-11
    • /
    • 2009
  • Objectives : The object of this study is to investigate the balance/imbalance of skin capacitances between left and right meridians, and to analyze the change patterns of electric energy on meridians with the lapse of time. Method : Electric potential was measured on five source points (LU9, PC7, HT7, LI4, SI4) bilaterally for 4 hours. The energy balance/imbalance between left and right was investigated, and the change patterns with time were analyzed. Results and Conclusions : The amplitude of meridian energy on five source points and the energy balance/imbalance between left and right were varied in each individual. When a source point showed a balanced meridian energy bilaterally, the change patterns of meridian energy with time were similar between left and right. While, when it showed an imbalanced energy between left and right, the change patterns of meridian energy were also different between left and right. Through this study, we proposed a new diagnostic method of meridian energy.

  • PDF

Development & Evaluation of acupuncture Point Impedance Measurement System Using 12 Channels Multi-Frequency (12채널 Multi-frequency를 이용한 경혈 임피던스 측정시스템 개발 및 평가)

  • Kim, Soo-Byeong;Lee, Jae-Woo;Lee, Seung-Wook;Lee, Na-Ra;Kim, Young-Dae;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2011
  • Objectives : The object of this study is to evaluate and develop the system that reflects acupoints electrical properties by the multi-frequency using the SPAC (Single Power Alternative Current) stimulation method based on BIA (Bioelectrical impedance method). Methods : The 12 channel meridian impedance measurement system (MIMS) was designed, which sets multi-frequency with 10 steps (1~10kHz). To check acupoints electrical properties, impedance of acupoints were measured from 11 acupoints selected from the LU and ST meridians. Results : Regarding distribution of measurement values by multi-frequencies, we found the lowest response at 1kHz was in common. But frequency bands which represent the highest response at each acupoint were various. Measurement values of each acupoint by multi-frequencies were expressed similar distribution (P<0.05). Also we could check same frequency band which showed the highest response at left/right equal acupoints (P<0.05). Conclusions : Through change of acupoints electrical properties by multi-frequency stimulation, we checked oriental medical diagnostic possibilities by using this system. We would progress variable clinical trials with this system for oriental medical diagnosis.

$CO_2$ Capture Process using Aqueous Monoethanolamine (MEA): Reduction of Solvent Regeneration Energy by Flue gas Splitting (모노에탄올아민(MEA)을 이용한 이산화탄소 포집공정: 배가스 분할 유입을 통한 흡수제 재생 에너지 절감 연구)

  • Jung, Jaeheum;Lim, Youngsub;Jeong, Yeong Su;Lee, Ung;Yang, Seeyub;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.764-768
    • /
    • 2011
  • The process of $CO_2$ capture using aqueous Monoethanolamine(MEA) has been considered as one of the leading technologies for intermediate-term strategy to reduce the $CO_2$ emission. This MEA process, however, consumes relatively a large amount of energy in the stripper for absorbent regeneration. For this reason, various process alternatives are recently established to reduce the regeneration energy. This paper suggests a flue gas split configuration as one of MEA process alternatives and then simulates this process using commercial simulator. This flue gas splitting has an effect on reducing the temperature of the lower section of absorber as well as decreasing the absorbent flow rate. Compared to the base model, this optimized flue gas split process provides 6.4% reduction of solvent flow rate and 5.8% reduction of absorbent regeneration energy.

Design of Oriental Medicine diagnosis system by Bio-Electric Response (생체-전기적 반응에 의한 한의학적 진단시스템의 설계)

  • 이용흠;장근중;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.420-429
    • /
    • 2004
  • It has been needed diagnosis technology of the EFG(Electro Functio Gram) measurement concept which is incorporated characteristic of modern science and biomedical engineering, because function abnormality diagnosis can't diagnose with visualization instruments or clinical pathology. The general diagnosis system(EFG system) has been developed to use basic diagnosis instrument that has reappearance, reliance and convenience using the functio diagnosis technology, in the field of western/oriental medicine. Also, we improved sticking electrode and simultaneous measurement method of the limbs 8CH, head 2CH to diagnose body circulation of Qi and acupoints for Oriental Medicine diagnosis/therapy. The result of clinical for adult man 20 persons, the EFG system can diagnose state of 12 meridians and autonomic nervous system. Therefore, in this paper, we designed of oriental medicine diagnosis system by bio-electric response with materialized H/W and S/W for 12 meridians state diagnosis of human body and system construction of the EFG.

Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results (Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰)

  • Kim, Soo-Byeong;Lee, Na-Ra;Lee, Seung-Wook;Choi, Jun-Young;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

Evaluation of Anti-Inflammatory Effect of Pulsed Electromagnetic Field on DNCB-Induced Atopic Dermatitis Using Principal Component Analysis (주성분 분석을 이용한 펄스형 전자기장 자극을 통해 DNCB로 유발된 아토피성 피부염의 개선 효과 분석)

  • Lee, Jiyoung;Kim, Jun-Yong;Lee, Yerin;Kim, Ko Eun;Lee, Yongheum;Yang, Sejung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.94-99
    • /
    • 2021
  • Atopic dermatitis (AD), a chronic inflammatory skin disease, is characterized by itchy and age-dependent lesions. Previous studies have shown that pulsed electromagnetic field (PEMF) significantly improved chronic ulcers and ununited fractures, providing an evidence for the application of PEMF in resolving inflammation caused by AD. This study investigated the anti-inflammatory effect of PEMF on DNCB-induced AD in animal models. Five male hairless mice (6 weeks old) per group were assigned to a normal group, a sham group, and two PEMF groups (15Hz, 75Hz). Mice were treated with 2,4-Dinitrochlorobenzene (DNCB) to induce uniform AD among all groups excluding a normal group. To examine the inflammatory progress and the improvement of AD after the PEMF stimulation, images are taken with various cameras for non-invasive evaluation and the results are expressed using principal component analysis (PCA) for visualization. The results of this study demonstrated that PEMF effectively improved skin lesions without the use of drugs.

VPN Traversal Scheme in Hierarchical MIPv4 environment (계층적 이동 IPv4 환경에서 VPN 운영 방안)

  • Sung, Su-Lyun;Kang, Jung-Ho;Shin, Young-Tae
    • The KIPS Transactions:PartC
    • /
    • v.11C no.4
    • /
    • pp.519-526
    • /
    • 2004
  • This paper presents an efficient interoperation scheme of a VPN(Virtual Private Network) and Mobile IP using a hierarchical structure of a FA(Foreign Agent). In the proposed scheme, the GFA(Gateway Foreign Agent) plays a role of VPN gateway on behalf of the MN(Mobile Node). When the MN moves in the same GFA domain, because the GFA has already an IPsec security association with a VPN gateway in the home network of the MN, the MN does not need an IPsec re-negotiaion. In this way, our mechanism reduces a message overhead and a delay resulted from an IPsec negotiation. And a MN can send a data to a correspondent node without a packet leakage. We show a performance of our scheme by using a discrete analytical model. Analytical results demonstrated that the total processing cost calculated by a registration update cost and a packet delivery cost is significantly reduced through our proposed scheme.

Analysis of Pupil Size Variability for Effectiveness Verification of Activation Level of Autonomic Nerve System by Electromagnetic Acupuncture System (자화침 시스템의 자율신경계 활성화 효과 검증을 위한 동공크기변이 분석)

  • Liu, Wenxue;Lee, Na-Ra;Choi, Woo-Hyuk;Kim, Soo-Byeong;Lee, Young-Heum;Shin, Tae-Min
    • Korean Journal of Acupuncture
    • /
    • v.29 no.4
    • /
    • pp.554-562
    • /
    • 2012
  • Objectives : The purpose of this research is to verify the effects of the Electromagnetic acupuncture(EMA) on BL15 by Pupil size variability(PSV) which is directly related to the activation of the Autonomic Nervous System. Methods : Thirty male subjects participated in this study and were divided into three groups(non-stimulated, manual acupuncture and EMA group). The size of pupil was measured in the cube place of $60{\times}60{\times}60$ cm in order to avoid the effect of the surrounding circumstances. All subjects were measured the size of left pupil about 200sec in the constant illumination. Results : We observed the decrease in PSV of manual acupuncture group compared to non-stimulation group, but it was not significant statistically(p>0.05). The decrease in PSV of EMA group was observed in comparison to two groups, and we confirmed the result of significant difference statistically(p<0.05). Conclusions : We concluded that EMA treatment method is enough to activate in the parasympathetic nerve system by inducing the biotransformation.

Enviromentally Friendly Aqueous/Semi-aqueous Cleaning Technology (환경친화적 수계/준수계 세정 기술)

  • Bae, Jae-Heum;Kim, Jung-Sik
    • Clean Technology
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 1997
  • CFC and organic chlorine solvents has been used in the fine machinery and electronics industries for a long time since they have various excellent properties as cleaning agents. However, it is inevitable that alternative cleaning agents should be used since CFC and organic chlorine solvents were identified as ozone-depleting chemicals. There are various alternative cleaning agents. Among them, aqueous/semi-aqueous cleaning agents are environmentally friendly and promising in the long term. And their use and developement are on the increase in advanced countries, but few in our countries. In this paper, the charactistics and major components aqueous/semi-aqueous cleaning agents are analyzed and compared. And various cleaning equipments for aqueous/semi-aqueous cleaning agents such as immersion cleaner, ultronsonic cleaners, power spray cleaner, and vibration or rotational cleaners are compared and evaluated. Finally, important consideration points for selction of a cleaning system are analyzed and suggested in this paper.

  • PDF