• Title/Summary/Keyword: 이완시간

Search Result 375, Processing Time 0.026 seconds

Prevalence of Postprandial Hypotension in the Elderly People with Hypertension according to Mealtimes (고혈압노인의 식사시간 별 식후저혈압 발생실태)

  • Son, Jung Tae;Lee, Eunjoo;Kim, Hyeonmi
    • 한국노년학
    • /
    • v.31 no.4
    • /
    • pp.969-983
    • /
    • 2011
  • The purposes of this study were to identify the degree of postprandial blood pressure reduction and the prevalence of postprandial hypotension by 3 different mealtimes of elderly people diagnosed with hypertension in nursing homes. After the informed and written consent, a total of 187 elderly people were recruited in the study. Systolic BP, diastolic BP were measured with ambulatory BP monitor every 15 minutes interval from 30 minutes before a meal until 120 minutes after each meal. The maximum SBP reduction was significantly bigger at breakfast than lunchtime or dinnertime. Among 187 elders, 137(73.4%) showed PPH at breakfast, 103(54.2%) at lunchtime, and 96(50.2%) at dinnertime. The most prevalent time point of PPH was 90 minutes after the initiation of a meal in all of 3 mealtimes. Among 8 measurement times, the prevalence of PPH was significantly higher in breakfast (3.0±2.7 times) than both lunchtime (2.1±2.5 times) and dinnertime (1.9±2.4 times). Although the occurrence of PPH by every mealtime should be taken into account in caring for the elderly, postprandial BP measurements need more attention after breakfast. Nurses should develop appropriate nursing interventions that can prevent postprandial blood pressure reduction in elderly people with hypertension.

Evaluation of Optimal Combination of Commercially Available Superparamagnetic Iron Oxide Nanoparticles and Transfection Agents for Labelling of Human Mesenchymal Stem Cells (인체 중간엽 줄기세포의 표지를 위한 상용화 된 Superparamagnetic Iron Oxide Nanoparticle과 Tansfection Agent의 적절한 병용을 위한 연구)

  • Kim, Sung-Hun;Oh, Soon-Nam;Park, Youn-Hee;Kang, Won-Kyung;Ahn, Kook-Jin;Chung, Soo-Kyo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2012
  • Purpose : To determine the optimal combination of commercially available superparamagnetic iron oxide (SPIO) nanoparticles with transfection agents (TA). Materials and Methods: Protamine sulfate (Pro) and poly-L-lysin (PLL) were incubated with ferumoxide and ferucarbotran in human mesenchymal stem cells at various concentrations, and cellular viability were evaluated. Cellular iron uptake was qualitatively and quantitatively evaluated. Cell visibility was assessed via MR imaging and the T2-relaxation time was calculated. Results: The cellular viabilities with ferucarbotran were more significantly decreased than those with ferumoxide (p < 0.05). Iron uptake with ferumoxide was significantly higher than that for those with with ferucarbotran. The T2-relaxation time was observed to be shorter with ferumoxide in comparison to those with ferucarbotran (p < 0.05). Ferumoxide at a concentration of 25 ${\mu}g$/ml in combination with either Pro or PLL at a concentration of 3.0 ${\mu}g$/ml did not adversely impact cell viability, maximized iron uptake, and exhibited a lower T2-relaxation time in comparison to other combinations. Conclusion: Stem cells with ferumoxide exhibited a higher cellular viability and iron uptake in comparison to ferucarbotran-treated stem cells. A 25 ${\mu}g$/ml of ferumoxide with a 3.0 ${\mu}g$/ml of TA is sufficient to label mesenchymal stem cells.

Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI (3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향)

  • Kim, Ho-Hyun;Kwon, Soon-Yong;Lim, Woo-Teak;Kang, Chung-Hwan;Kim, Kyung-Soo;Kim, Soon-Bae;Baek, Moon-Young
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF

Response of Ultrafiltration Flux to Periodic Oscillations in Transmembrane Pressure Gradient (압력구배의 주기적 변화에 따른 한외여과 Flux의 변화)

  • 서창우;이은규
    • KSBB Journal
    • /
    • v.14 no.2
    • /
    • pp.230-234
    • /
    • 1999
  • To improve the crossflow untrafiltration flux, we applied periodic oscillations in transmembrane pressure gradient in order to promote fluid turbulence by inducing repeated compression and relaxation of the cake/gel layer. The oscillatory forms used were square-, sine-, triangle-wave, and pumping interruption. The permeate flux profiles were mathematically simulated and compared with the experimental data. The result showed the periodic pumping interruption most effectively improved the overall flux by up to about 32%. Enough pumping off-time, at least on the order of tens of seconds, was needed to allow the solutes in the layer to diffuse back to the bulk phase. It was better to start the oscillations earlier before the layer was fully established. The square-wave oscillation yielded about 11% increase, which was particularly pronounced in the later part of the filtration. Either the amplitude or the period of the oscillations resulted little influence on flux.actate ester, and lactate ester produced in esterification reaction was distilled simultaneously with hydrolysis reaction into lactic acid. When the yields of lactic acid recovered by batch reactive distillations with various alcohols were compared, the yield of lactic acid was increased as the volatility of lactate ester was increased. In this batch reactive distillation, because the mixtures condensed in partial condensor were flown to reboiler through distillation column, the recovery yield of lactic acid was affected by operation temperature of partial condensor. Hydrolysis reaction into lactic acid in distillation column rarelyoccurred because of short retention time of lactate ester and water. Lactate ester was reacted into lactic acid in reboiler.

  • PDF

Construction of T$_1$ Map Image (T1 이완시간의 영상화)

  • 정은기;서진석;이종태;추성실;이삼현;권영길
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.83-92
    • /
    • 1995
  • The T1 mapping of an human anatomy may give a characteristic contrast among the various tissues and the normal/abnormal tissues. Here, the methodology of constructing T1 map out of several images with different TRs, will be described using non-linear curve fitting. The general curve fitting algorithm requires the initial trial values T1t and Mot for the variables to be fitted. Three different methods of suppling the trial T1t and Mot are suggested and compared for the efficiency and the accuracy. The curve-fitting routine was written in ANSI C and excuted on a SUN workstation. Several distilled-water phantoms with various concentrations of Gd-DTPA were prepared to examine the accuracy of the curve-fitting program. An MR image was used as the true proton density image without any random noise, and several images with different TRs were generated with the theoretical T1 relaxation times 250, 500, and 1000msec. The random noise of 1, 5, and 10% were embedded into the simulated images. These images were used to generate the T1 map, and the resultant T1 maps for each T1 were analyzed to study the effect of the random noise on the T1 map.

  • PDF

The Vasodilating Mechanism of Sodium Nitroprusside and Forskolin on Phorbol dibutyrate-Induced Contractions in Rat Aorta (Sodium nitroprusside와 Forskolin의 Phorbol ester 수축에 대한 혈관이완작용의 기전)

  • Ahn, Hee-Yul
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.3
    • /
    • pp.291-297
    • /
    • 1995
  • The objectives of this study is to compare the inhibitory mechanism of sodium nitroprusside and forskolin on the phorbol ester, activator of protein kinase C (PKC), -induced contractions in rat aorta. $0.1\;{\mu}M$ phorbol dibutyrate (PDBu) induced sustained contractions and increased phosphorylations of myosin light chain (MLC) time-dependently. At 30 min, the contractions and phosphorylations of MLC by PDBu were augmented maximally and remained constant. Moreover, $^{45}Ca^{2+}$ uptake was increased 30 min after PDBu stimulation from resting values. Sodium nitroprusside which activates guanylyl cyclase followed by increasing cGMP, inhibited the PDBu-induced contractions concentration-dependently. On the other hand, forskolin which activates adenylyl cyclase followed by increasing cAMP, also inhibited the PDBu-induced contractions concentration-dependently. However, sodium nitroprusside was more potent to inhibition of the PDBu-induced contractions than forskolin. Sodium nitroprusside inhibited $^{45}Ca^{2+}$ uptake by PDBu stimulation. Forskolin also inhibited $^{45}Ca^{2+}$ uptake by PDBu stimulation. Sodium nitroprusside and forskolin inhibited the phosphorylations of MLC by PDBu, respectively. However, sodium nitroprusside was more potent to inhibition of phosphorylations of MLC by PDBu than forskolin. From these results, Sodium nitroprusside via cGMP or forskilin via cAMP may reduce myoplasmic $Ca^{2+}$ followed by suppression of phosphorylations of MLC of PKC-mediated contractions, which results in vasodilation. However, cGMP may play a role more importantly than cAMP on the regulation of protein kinase C-mediated contraction in vascular smooth muscle.

  • PDF

Creep Analysis for the Pressurized Water Reactor Spent Nuclear Fuel Disposal Canister (가압경수로 고준위페기물 처분용기에 대한 크립해석)

  • Ha Joon-Yong;Choi Jong-Won;Kwon Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.413-421
    • /
    • 2004
  • In this paper, a structural analysis for the pressurized water reactor(PWR) spent nuclear fuel disposal canister which is deposited under the 500m deep underground is carried out to predict the creep deformation of the canister while the underground water and swelling bentonite pressure are applied on the canister. Usually the creep deformation may be caused due to the Pressure and the high heat applied to the canister even though additional external loads are not applied to the canister. These creep deformations depend on the time. In this paper, oかy the underground water and bentonite swelling Pressure are considered for the creep deformation analysis of the canister, because the heat distribution inside canister due the spent fuel is not simple and depends on time. A proper creep function is adopted for the creep analysis. The creep analysis is carried out during $10^8$ seconds. The creep analysis results show that the creep strains are very small and these strains occur usually in the lid and bottom of the canister not in the cast iron insert. A much smaller strain is found in the cast iron insert. Hence, the creep deformation doesn't affect the structural safety of the canister, and also the creep stress which shows the stress relaxation phenomenon doesn't affect the structural safety of the canister.

Transmembrane Pressures with Respect to Backwashing and Sinusoidal Flux Continuous Operation Modes for the Submerged Hollow Fiber Membrane in the Activated Sludge Solution (활성슬러지 수용액 내 침지식 중공사막의 역세척 및 사인파형 연속투과 운전방식에 따른 막간차압)

  • Jeong, Doin;Jung, Seung Hee;Lee, Sohl;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.524-529
    • /
    • 2015
  • In this study transmembrane pressure (TMP) was measured with respect to operational time by applying the sinusoidal flux continuous operation (SFCO) for the hollow fiber membrane. The hollow fiber module which has $100cm^2$ of effective area and $0.45{\mu}m$ nominal pore size was submerged in the activated sludge solution of MLSS 5,000 mg/L. The critical permeate flux was measured as $26.6L/m^2{\cdot}hr$ by the method of continuous flux step change. TMPs of the filtration/relaxation (FR), FR with backwashing (FR/BW) and SFCO modes were measured. The SFCO mode was more effective than FR and FR/BW modes below the critical permeate flux such as 15, 20 and $25L/m^2{\cdot}hr$. However, the FR/BW was confirmed as more effectively fouling controlled mode than SFCO mode above the critical permeate flux.

Time-lapse Geophysical Survey Analysis for Field-scale Test bed of Excavation Construction (실규모 굴착 시험장에서의 시간경과 물리탐사 자료 분석)

  • Shin, Dong Keun;Song, Seo Young;Kim, Bitnarae;Yoo, Huieun;Ki, Jung Seck;Nam, Myung Jin
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.137-151
    • /
    • 2019
  • Geophysical exploration techniques are effective for monitoring changes in the ground condition around the excavation project to prevent subsidence risks during excavation work, therefore, improving analysis techniques is required for applying and supplementing various geophysical exploration technologies. In this study, a field-scale on-site test was conducted to detect possible ground subsidence hazards and areas of relaxation zone that may occur during excavation work and due to underground water level changes. In order to carry out the field test, a real-scale excavation test bed was constructed and the geophysical exploration methods, such as electrical resistivity survey and multi-channel analysis of surface wave (MASW) survey for urban sites condition, have researched for optimal geophysical exploration parameter, design and correlation analysis between the results by reviewing the validity of each individual geophysical exploration and modeling. The results of this study showed the impact of each geophysical exploration on the relaxation zone and, in particular, the location of the underground water surface and the effects of excavation were identified using electrical resistivity survey. Further research on modeling will be required, taking into account the effects of excavation and groundwater.

Suction Pressures with respect to the Operational Modes using the Multi-bore Capillary Membranes in the Membrane Bioreactor (생물막 반응기내 다공성 중공사형막을 이용한 운전방식에 따른 흡입 압력)

  • Kim, Min Hyeong;Koo, Eeung Mo;Lee, Min Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.343-350
    • /
    • 2021
  • In this study the suction pressure was measured with respect to operational time by submersing the multi-bore capillary membrane module in membrane bioreactor(MBR). The hexagonal shape capillary module which has the nominal pore size of 0.2 ㎛, outer diameter of 6.4 or 4.2 mm was immersed in MLSS 8,000 mg/L active sludge aqueous solution, and confirmed changes with respect to permeation flux and air flow rate. It was operated by the filtration/relaxation(FR), FR with backwashing(FR/BW), and sinusoidal flux continuous operation(SFCO) modes. The suction pressure for the SFCO and FR modes was lower at 30 and 50 L/m2·hr, respectively. In addition, the suction pressure of the module with a small outer diameter was relatively low. The suction pressure of a large outer diameter was greatly increased, but it could be reduced by more than 40% by backwashing.