Nitrate Ion-Selective Membrane Electrode Based on Complex of (Bakelite-A)-(2,2'-Bipyridine)-Ni(Ⅱ) Nitrate ((Bakelite-A)-(2,2'-Bipyridine)-Ni(Ⅱ) 착물의 질산이온 선택성 막전극)

  • Doo-Soon Shin;Chung Ki-Won
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.3
    • /
    • pp.383-392
    • /
    • 1992
  • (Bakelite-A)-(2,2'-Bipyridine)-Ni(Ⅱ) Nitrate complexes were tested as ion exchanger for nitrate ion-selective electrode. The experimentally observed selectivity and electrode characteristics were relatively in good agreement with the exchanger lipophilicity in the membrane phase. Based on chemical composition, mechanisms for exchange with nitrate ion and internal electrical conduction were postulated. Analytical application to the determination of nitrate were studied.

  • PDF

Nitrate Ion-Selective Membrane Electrode Based on Complex of Ammonia Modified Bakelite A-Ni(II) Nitrate (Bakelite A-Ni(II) 착물의 질산이온 선택성 막전극)

  • Kim, Hwan-Ki;Shin, Doo-Soon
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.271-279
    • /
    • 1987
  • A nitrate ion-selective PVC membrane electrode based on ammonia modified bakelite A-Ni$(NO_3)_2$ complex as ion exchanger was prepared. The electrode gave a linear response with a Nernstian slope of 60mV per decade within the concentration range $1{\sim}10^{-4}$ M $KNO_3$ but nonresponse to hydrogen ion and multivalent anions. The selectivity, response time and life time of the electrode were investigated and it was found that the electrode exhibited good selectivity for four univalent anions ($Cl^-,\;Br^-,\;I^-,\;{ClO_4}^-$). Analytical application to the determination of nitrate were also studied.

  • PDF

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

Cesium Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore (캘릭스 [4]크라운 유도체를 이온선택성 물질로 사용한 세슘이온 선택성 막전극)

  • Namgung, Miok;Ihm, Hyejae;Paek, Kyungsoo;Yun, Youngja
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.428-432
    • /
    • 2000
  • A PVC membrane electrode based on upper-rim calix[4]crown as ionophore was prepared using dioctyl sebacate (DOS) as a plasticizer. The potential response of this membrane electrode to alkali, alkaline earth metal cations were examined. This membrane electrode exhibited a Nemstian response to $10^{-5}-10^{-1}M$ of CsCI with a slope of 52.3 mV/decade in Tris-buffer(pH 7.20). Its response time ($t_{90%}$) was 10s and it could be used for at least 2 months.

  • PDF

Characteristics and Preparation of Potassium Ion Selective Liquid Membrane Electrode Based on Polyurethane Matrix (폴리우레탄을 메트릭스로한 액막형 칼륨이온 선택성 전극의 제조 및 특성)

  • Kwang Sik Yoo;Yong Tack Lee;Chul Yong Kang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.128-134
    • /
    • 1991
  • Previous matrices of potassium ion selective electrodes are generally based on PVC. In this study, however, the electrode membrane was prepared with polyurethane matrix containing potassium tetraphenyl borate as sensing materials and D-18-Crown-6 and 2-nitrophenyl-n-alkylethers as solvent mediator. The average life time of the K$^+$-selective electrode based on polyurethane was 75 days which is significantly longer than PVC based one. The slope factor in linear dynamic range ($1{\times}10^{-1}\;{\sim}\;1{\times}10^{-4}$ M) was 52 mV/decade. The electrode has been successfully applied to find end point in potentiometric titration of K$^+$ with tetraphenyl borate solution in the sea water, even in the presence of several interfering cations$(NH^{4+},\;Na^{+},\;Li^{+},\;Ca^{2+},\;Mg^{2+},\;Cu^{2+}$).

  • PDF

Preparation of a Liquid Membrance Type Ion-Selective Electrode and Its Application to the Potentiometric Titration (액체막형 구리이온 선택성 전극의 제작과 전위차적정에의 응용)

  • Heung Lark Lee;Seung Tae Yang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.137-143
    • /
    • 1985
  • Construction of a liquid membrane type of cupric ion selective electrode and its application to the potentiometric titration have been studied. A liquid ion-exchange membrance was prepared by extracting Cu(II) in aqueous solution into 1-(2-pyridylazo)-2-naphthol/nitrobenzene. A Ag/AgCl internal reference electrode was dipped into the aqueous reference solution of $1.00 {\times} 10^{-3}M\;Cu(NO_3)_2$ buffered with HAc-NaAc buffer solution, which was in contact with the nitrobenzene extract. The electrode showed the nernstian response to Cu(II) in the concentration range from $1.00{\times} 10^{-6}$ to $1.00{\times} 10^{-3}$M. The most suitable ion-exchanger concentration in the liquid membrane was $1.00{\times} 10^{-4}$M. The selectivity coefficients of the electrode for the various metal cations were investigated. The electrode was applied to the potentiometric titration of Cu(II) with EDTA.

  • PDF

A Highly Selective Mercury(II) Ion-Selective Membrane Sensor (고 선택성 수은(II) 이온 막 센서)

  • Ensafi, Ali A.;Meghdadi, S.;Allafchian, Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.324-330
    • /
    • 2007
  • A new ion selective PVC membrane electrode is developed as a sensor for mercury(II) ions based on bis(benzoylacetone) propylenediimine (H2(BA)2PD) as an ionophore. The electrode shows good response characteristics and displays, a linear Emf vs. log[Hg2+] response over the concentration range of 1.0×10-6 to 1.0×10-1 M Hg(II) with a Nernstian slope of 29.8±0.75 mV per decade and with a detection limit of 2.2×10-7 M Hg(II) over the pH range of 2.5-11.5. Selectivity concentrations for Hg(II) relative to a number of potential interfering ions were also investigated. The sensor is highly selective for Hg(II) ions over a large number of cations with different charge. The sensor has been found to be chemically inert showing a fast response time of 60 s and was used over a period of 3 months with a good reproducibility (S = 0.27 mV). The electrode was successfully applied to determine mercury(II) in real samples with satisfactory results.

Tallium(I) Ion-Selective Electrodes Based on Crown Ethers (크라온에테르를 이용한 탈륨(I) 이온 선택성 전극)

  • Sung Min Kim;Sung Uk Jung;Jineun Kim;Jae Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.773-778
    • /
    • 1993
  • Poly(vinyl chloride)(PVC) membrane electrodes based on the lipophilic neutral carrier, dibenzo-18-crown-6(DB18C6) and benzo-15-crown-5 (B15C5) as the active sensors for Tl$^+$ ion have been prepared and tested in different content of the potassium tetrakis(4-chlorophenyl)borate (KTClPB) as lipophilic salt. Dioctyl adipate (DOA), 2-nitrophenyl phenyl ether (NPPE) and o-nitrophenyl actyl ether (NPOE) were used as plasticizing solvent mediators. Electrodes exhibited good linear responses of 40∼55 mV decade$^{-1}$ for Tl$^+$ ion within the concentration ranges 10$^{-1}$∼10$^{-5}$M TlNO$_3$. Selectivity coefficients of interfering ions (alkali metal, alkaline earth metal and some transition metal ions) for Tl$^+$-ISE were determined by separate solution method and were sufficiently small for most of them. These crown ether type ion-selective electrodes are suitable for use with aqueous solution at pH > 3.

  • PDF

Correcting Errors Associated with Blood Urea Measurements Employing Nonaction-Doped Ammonium-Selective Electrodes (암모늄선택성 전극을 이용한 요소센서의 오차보정에 관한 연구)

  • Kim, Young No;Shin, Doo Soon;Kim, Chang Yong;Shin, Jae Ho;Nam, Hakhyun;Cha, Geun Sig
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.925-931
    • /
    • 1995
  • Urea sensors, prepared by immobilizing urease on ammonium-selective membrane electrodes doped with nonactin, can show interference from several ionic species present in blood samples (e.g., sodium, potassium, and endogenous ammonium ions). This interference problem does not arise from the immobilized biocatalytic reaction but rather from the innate response of the base transducer to ionic species in the sample. In this work, the use of calibrators containing adequate amounts of ionic species is examined to reduce errors caused by endogenous ionic interferences with blood urea measurements. Simultaneous measurements of the interfering species with additional sensors and subsequent substractions of these values from the urea electrode signals are also described. It is shown that the use of a potassium-selective electrode with an adequate calibrator system greatly enhances the accuracy of the urea sensor measurements.

  • PDF

Silicone Rubber Membrane-Based Chloride Ion-Selective Electrode (실리콘러버-지지체 염화이온선택성 막전극)

  • Sakong, Dong-Sik;Kim, Jin-Mog;Cha, Jin-Mog
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.12
    • /
    • pp.653-660
    • /
    • 1997
  • Silicone rubber-matrix membranes doped with tetradecyltrimethylammonium chloride (TDTMACl) are used to enhance electrode performance for chloride measurements in physiological samples. The optimized membrane formulation incorporates 95.4 wt% silicone rubber and 4.6 wt% TDTMACl, and its pH response is negligible in the range of pH 6-10. The TDTMACl-doped silicone rubber membrane exhibits sub-Nernstian response to chloride from 10 to 300 mM (-37.5 mV/decade), but its selectivities for chloride over other anions are remarkably enhanced: KpotCl,NO3=1.3, KpotCl,I=2.0, KpotCl,Sal=0.8, KpotCl,SCN=2.0 and KpotCl,ClO4=0.8. Furthermore, since the silicone rubber-matrix membrane exhibits better adhesion to the solid surface than do PVC membranes, the lifetime of the coated-wire type membrane electrode is greatly improved. The response properties toward chloride and salicylate for solid-state sensor are not significantly changed after at least 35 days of use.