• Title/Summary/Keyword: 이온함

Search Result 757, Processing Time 0.023 seconds

Photoluminescence of $SrTiO_3$: $Pr^{3+}$,$Ga^{3+}$ ($SrTiO_3$: $Pr^{3+}$,$Ga^{3+}$의 발광특성)

  • 변재동;이용제;장보윤;이현덕;유영문;류선윤
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.8
    • /
    • pp.705-709
    • /
    • 2001
  • SrTiO$_3$에 Pr$^{3+}$ 이온, 또는 Pr$^{3+}$ 이온과 Ga$^{3+}$ 이온을 첨가하여 합성한 형광체와 floating zone method로 성장시킨 단결정의 PL 특성을 조사하였다. 분말 형광체와 단결정에서 모두 Ga$^{3+}$ 이온이 함께 첨가되었을 때 적색 발광 세기가 크게 증가하였다. XRF(X-Ray Fluorescence) 측정결과 Ga$^{3+}$ 이온이 함께 첨가되었을 때 SrTiO$_3$결정 격자내의 Pr$^{3+}$ 이온의 농도가 증가하였다. Ga$^{3+}$ 이온이 함께 첨가되었을 때 적색 발광 세기가 증가하는 것은 첨가된 Ga$^{3+}$ 이온이 결정내 발광 center인 Pt$^{3+}$ 이온의 농도가 증가시켰기 때문이며, 또한 Ga$^{3+}$ 이온이 hole trap center로 작용하기 때문인 것으로 생각된다.

  • PDF

가스장 이온 소스(Gas Field Ionization Source)기반의 이온총 개발과 특성

  • Park, In-Yong;Jo, Bok-Rae;Han, Cheol-Su;Heo, In-Hye;Kim, Yeong-Jun;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.254.1-254.1
    • /
    • 2013
  • 현재의 나노기술 및 부품은 나노미터 이하의 초고분해능을 요구하면서도 나노미터 이하의 정확도로 가공할 수 있는 기술을 요구하고 있다. 이온현미경은 위 두 요구조건을 만족하는 차세대 현미경으로써 초고분해능 이미징과 함께 기존의 갈륨이온을 사용하는 집속이온빔 장치보다 네온가스등을 이용하여 더 정밀하게 에칭 및 스퍼터링을 할 수 있다. 이온현미경은 전자현미경에 비해 더 깊은 초점심도를 갖으며, 색수차와 구면수차에 비교적 둔감하고 전자에 비해 무거운 이온의 무게 때문에 짧은 파장을 갖는 특징을 가지고 있다. 이와 같은 특징을 이용하면 전자현미경과 다른 여러 특징과 장점을 갖는 고분해능의 현미경을 제작할 수 있다. 이와 같이 차세대 현미경으로 주목받는 이온현미경의 중요한 부분인 이온총은 현재 가스장 이온 소스 방법으로 대부분 개발되고 있다. 가스장 이온 소스는 1950년대에 E. W. Muller에 의해 개발된 전계 이온 현미경(Field Ion Microscope)에서 응용된 방법으로 뾰족한 탐침에서의 가스 이온화를 기반으로 한다. 가장 보편적으로 사용되는 재질은 텅스텐으로 수십 nm 정도의 곡률 반경을 갖도록 제작하고 초고진공에 설치하여 강한 양전압을 인가함과 동시에 가스를 팁 주변에 넣어주면 팁표면에서 이온빔이 발생하게 된다. 본 연구에서는 위와 같이 차세대 나노장비로써 주목받는 이온현미경의 특징에 대해 소개하고, 특히 이온현미경의 이온총 원천기술 개발을 위해 연구하고 있는 가스장 이온 소스의 특성에 대해 소개한다. 수소, 네온, 헬륨의 전계 이온현미경과 함께 생성된 이온빔의 안정도 및 각전류 밀도를 계산하여 실제 이온총으로의 적용 가능성에 대해 보여준다.

  • PDF

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards (물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Chan-Hyeong;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This work is for the preliminary study for the calibration of an $^{192}Ir$ brachytherapy source based on an absorbed dose to water standards. In order to calibrate brachytherapy sources based on absorbed dose to water standards using a clyndirical ionization chamber, the beam quality correction factor $k_{Q,Q_0}$ is needed. In this study $k_{Q,Q_0}s$ were determined by both Monte carlo simulation and semiexperimental methods because of the realistic difficulties to use primary standards to measure an absolute dose at a specified distance. The 5 different serial numbers of the PTW30013 chamber type were selected for this study. While chamber to chamber variations ran up to maximum 4.0% with the generic $k^{gen}_{Q,Q_0}$, the chamber to chamber variations were within a maximum deviation of 0.5% with the individual $k^{ind}_{Q,Q_0}$. The results show why and how important ionization chambers must be calibrated individually for the calibration of $^{192}Ir$ brachytherapy sources based on absorbed dose to water standards. We hope that in the near future users will be able to calibrate the brachytherapy sources in terms of an absorbed dose to water, the quantity of interest in the treatment, instead of an air kerma strength just as the calibration in the high energy photon and electron beam.

  • PDF

Effect of Nation binder with different equivalent weight on cell performance (이온당량(EW)이 다른 Nafion binder가 고분자 전해질 연료전지의 성능에 미치는 영향)

  • Kim, Kun-Ho;Kim, Hyoung-Juhn;Lim, Tae-Hoon;Lee, Kwan-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.129-132
    • /
    • 2007
  • 고분자 전해질 연료전지의 성능에 영향을 주는 많은 인자들 중에서도 촉매층의 조성과 구조의 최적화는 성능변화에 큰 요인으로 작용 된다. 촉매층내 반응 활성점인 삼상계면을 형성시키기 위해 함침하는 Nafion binder를 anode와 cathode의 두 전극에 이온당량(Equivalent weight, EW)이 동일하게 함침시켜 그 성능을 확인하였다. 그 결과를 토대로 anode와 cathode에 이온당량을 각기 다르게 하여 각각의 전극마다 이온당량이 미치는 영향에 대해서도 살펴보았다. Anode와 cathode의 이온당량을 동일하게 EW1100, EW1000, EW900으로 변화 시켜주었을 경우 이온당량의 물성치가 상대적으로 향상된 EW900의 단위 전지 성능이 가장 우수하였으며, 이온당량이 EW900이었을 때 최적의 Nafion binder 함침량은 EW1100의 Nafion binder 함침량과 동일하였다. Anode와 cathode에 함침하는 Nafion binder의 이온당량을 각각 EW1100과 EW900, EW900과 EW1100으로 MEA를 제조하여 전극에 따라 이용당량이 미치는 영향을 살펴보았다.

  • PDF

원자력발전소 1차계통 탈염기 제염계수 특성 분석

  • 성기방;강덕원
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.387-391
    • /
    • 1997
  • 냉각재중의 방사능을 띤 성분 중에는 이온교환기에서 제거가 가능한 이온성분과 함께 필터에 의해서 주로 제거되는 입자성 물질로 존재한다. 운전중의 냉각재내 방사성 부식생성물의 물리적 조성 분포 측정 결과에 따르면 90%이상이 0.45$mu extrm{m}$필터에 의해 제거되는 입자성 물질로 구성되어 있다. 이로 인해 새수지 충전후 얼마 사용하지 않은 탈염기의 제염계수가 탈염기에서 완벽한 제거가 어려운 입자성 부식생성물로 인해 10이하를 나타낼 수 있다. 1차계통에 쓰이는 수지의 성능검사를 위해 사용하고 있는 현재의 제염계수 측정법은 다음과 같은 두가지 이유로 완벽하지 않음을 알 수 있다. 첫째, 냉각재중의 방사능을 띤 성분중에는 이온교환기에서 제거가 가능한 이온성분과 함께 필터에 의해 제거되는 입자성 물질도 함께 존재하므로 탈염기의 제염계수 측정 절차는 입자성 물질을 배제한 후 측정해야 하며, 특히 수치 교체를 결정하기 위한 제염계수 측정시에는 여과된 여액으로 방사능 농도를 측정하는 것이 바람직하다. 둘째 운전중인 냉각재의 시료중에는 핵분열 수율이 높고 핵연료봉 손상부위로 유출이 용이한 불활성 기체핵종들이 많이 존재하며, 탈염기 후단에서 채취한 시료중에도 많이 존재하고, 시료 이송과 방사능 측정동안의 짧은 시간동안에도 계속 붕괴반응함으로서 새로 생긴 핵종으로 인해 마치 탈염기의 제거능이 낮은 것으로 오판될 수 있다. 이러한 측정 오차인자를 고려하여야 1차계통 탈염기의 교환능력을 정확히 판정할 수 있다.

  • PDF

공기의 질과 건강

  • Choe, Tae-Seop
    • Journal of Korea Far Infrared Association
    • /
    • s.24
    • /
    • pp.32-37
    • /
    • 2005
  • 공기이온에 관한 연구는 많은 분야의 연구원 참여에 의해 폭넓게 알려져, 반세기에 이르는 번영의 역사를 쌓아 왔지만, 불가사의하게도 현재, 가장 중요한 적용분야인 보건 분야에서 위기를 맞고 있다. 20세기 초, 대기 중에 전하를 띤 입자의 존재가 관찰된 이래, 공기 이온의 성질을 문제로 한 기초적 연구가, 간단한 공기이온계측기 보급과 함께, 물리학자, 생물학자, 의학자의 협력 하에 1930년대 이후 활발히 이루어져, 공기이온의 위생적ㆍ치료적 가치에 대한 풍부한 정보를 얻을 수 있게 되었다. 어찌되었든 이온화환 공기 속에서는 생활할 수 없는 것이 확실해져, 어떤 농도의 공기이온은 사람 및 동물의 생체에 유익한 작용을 하고, 대용량 공기이온은 치료에 적용가능하지만, 농도의 여하에 관계없이, 양이온이 음이온에 비해 2~3배 우세하면, 신체의 상태를 악화시켜며, 또한 공조설비와 필터류는 모두 이온화작용을 나타내는 것도 밝혀졌다. 청정한 공기를 이온화하는 것은 산소, 탄산가스, 약용물질분자를 활성화시키지만, 오염된 공기의 이온화는 유독한 불순물의 독성을 증가시키는 점도 지적되었다.

  • PDF