• 제목/요약/키워드: 이송관로용량

검색결과 2건 처리시간 0.018초

도시지역 CSOs 저감을 위한 저류조 및 이송관로의 최적 용량결정에 관한 연구 (Study on the determination of optimum size of storage tank and intercepting capacity for CSOs reduction in urban area)

  • 이관용;최원석;이용재;구원석;송창수
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.735-745
    • /
    • 2012
  • Storage method is one of major measures for reduction of CSOs pollutant loads and several projects have been done nationwide. But systematic analysis of intercepting capacity has not been studied to determine optimum size of storage facility. In this research, not only storage volume but also intercepting capacity which means flow capacity from intercepting facility to CSOs storage facility was studied and optimum sizing method for storage facility was proposed. The result shows that pollutants reduction efficiency can be increased significantly by increasing intercepting capacity and it might reduce storage volume and total construction costs. Intercepting capacity for the study area was evaluated and it was shown as equivalent to 83 % probability rainfall intensity.

발전 보일러용 비회 이송설비에서 최대 비회 이송량 예측 (Prediction of Maximum Fly Ash Conveying Capacity of Fly Ash System in a Power Plant)

  • 진경용;문윤재;이재헌;문승재
    • 플랜트 저널
    • /
    • 제11권1호
    • /
    • pp.50-57
    • /
    • 2015
  • 연구에서는 국내 D 석탄 화력발전소에서 비회 이송량 35,800 kg/h의 용량으로 운전 중인 비회 이송설비를 대상으로 최대 비회 이송량을 예측하였다. 수평거리 550 m, 수직거리 40 m, 엘보우 9개소, 직경 0.254 m의 이송관으로 구성된 비회 이송관로와 트립(trip) 정압 1,163 mmH2O, 풍량 5,040 m3/h인 용적식 비회 이송 송풍기로 이루어진 비회 이송 시스템에서 최대 비회 이송량은 비회 이송량의 증가에 따른 비회 이송 시스템의 압력 손실과 용적식 비회 이송 송풍기의 트립 정압이 같아질 때이며, 이 조건 하에서 가능한 최대 비회 이송량은 52,600 kg/h로 예상되었다.

  • PDF