• Title/Summary/Keyword: 이상 분할

Search Result 6,168, Processing Time 0.04 seconds

Degradation Pattern of Propanil (3',4'-dichloropropionanilide) as affected by Environmental Condition of Solution (Propanil (3',4'-dichloropropionanilide)의 용액중(溶液中) 환경조건(環境條件)에 따른 분해양상(分解樣相))

  • Shin, Yun Gyo;Kim, Jang Eok;Hong, Jong Uck
    • Current Research on Agriculture and Life Sciences
    • /
    • v.5
    • /
    • pp.33-39
    • /
    • 1987
  • In order to study the degradation pattern of propanil in solution, the environmental factors such as temperature, pH and UV irradiation effect on propanil degradation were investigated. The degradation of propanil in solution was more rapid in high temperature than in low. The production amount of DCA was increased in high temperature, and then was decreased in a certain period of time because of conversion to TCAB, but the concentration of TCAB was maintained without more degradation. Propanil was rapidly hydrolyzed in alkaline solution as well as in strong acidic solution. Degradation product, DCA was rapidly produced and condensed to TCAB in strong acidic and alkaline condition. On exposur to ultraviolet light, 90% of original propanil was degraded within 20minutes, 0.3 ppm of DCA was produced in 10 minutes, and maintained the concentration throughout irradiation times.

  • PDF

Electrical Characterization of c-Si Solar Cell with Various Emitter Layer

  • Park, Jeong-Eun;Byeon, Seong-Gyun;Lee, Yeong-Min;Park, Jun-Seok;Lee, Min-Ji;Im, Dong-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.413-413
    • /
    • 2016
  • 태양전지 제작 시 에미터층을 형성하는 도핑 공정의 최적화는 캐리어 수집 확률 증가와 함께 결정질 실리콘 태양전지 고효율화를 위해 매우 중요하다. 본 연구에서는 결정질 실리콘 태양전지 다이오드의 다양한 도핑 공정으로 제작된 p-n 접합에 대한 전기적 특성 분석을 진행하였다. 도핑 공정의 경우 선 증착-후 확산 공정 시간과 가스량을 변화시켜 다양한 에미터층을 제작하였다. 선 증착 시간 변화를 주는 경우 선 증착 공정을 $825^{\circ}C$로 고정한 뒤 시간을 7분에서 17분까지 변화하고 후 확산 공정을 $845^{\circ}C$, 14분으로 고정하였다. 후 확산 시간 변화를 주는 경우는 선 증착 공정을 $825^{\circ}C$, 12분으로 고정한 뒤 후 확산 공정을 $845^{\circ}C$로 고정 하고 시간을 9분에서 19분까지 변화시켰다. 선 증착 공정을 $845^{\circ}C$ 12분, 후 확산 공정을 $845^{\circ}C$, 14분으로 고정 한 뒤 선 증착 시 POCl3양을 400 ~ 1400 SCCM까지 변화시켰고, 후 확산 시 산소량을 0 ~ 1000 SCCM까지 가변한 조건에서 에미터층에 대한 특성을 분석하였다. 결과적으로 선 증착 공정 $825^{\circ}C$ 12분, 후 확산 공정 $845^{\circ}C$ 14분에서 SCR(Space Charge Region)에서 3.81의 가장 낮은 이상 계수 값을 나타내었다. 이는 p-n접합의 내부결함이 줄어들어 태양전지의 캐리어 수명이 증가됨을 보였다. 선 증착 공정 중 $POCl_3$ 주입량 800 SCCM, 후 확산 공정 중 산소량 400 SCCM에서 $15.9{\mu}s$로 가장 높은 캐리어 수명을 나타내었다. Suns-VOC 측정 결과 $POCl_3$ 주입량 800 SCCM, 산소량 400 SCCM에서 619mV로 가장 높은 개방전압을 얻을 수 있었다.

  • PDF

Object Segmentation/Detection through learned Background Model and Segmented Object Tracking Method using Particle Filter (배경 모델 학습을 통한 객체 분할/검출 및 파티클 필터를 이용한 분할된 객체의 움직임 추적 방법)

  • Lim, Su-chang;Kim, Do-yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1537-1545
    • /
    • 2016
  • In real time video sequence, object segmentation and tracking method are actively applied in various application tasks, such as surveillance system, mobile robots, augmented reality. This paper propose a robust object tracking method. The background models are constructed by learning the initial part of each video sequences. After that, the moving objects are detected via object segmentation by using background subtraction method. The region of detected objects are continuously tracked by using the HSV color histogram with particle filter. The proposed segmentation method is superior to average background model in term of moving object detection. In addition, the proposed tracking method provide a continuous tracking result even in the case that multiple objects are existed with similar color, and severe occlusion are occurred with multiple objects. The experiment results provided with 85.9 % of average object overlapping rate and 96.3% of average object tracking rate using two video sequences.

Kidney Tumor Segmentation Using a Hybrid CNN-Transformer Network for Partial Nephrectomy Planning (부분 신장 절제술 계획을 위한 하이브리드 CNN-트랜스포머 네트워크를 활용한 신장 종양 분할)

  • Goun Kim;Jinseo An;Yubeen Lee;Helen Hong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.4
    • /
    • pp.11-18
    • /
    • 2024
  • In partial nephrectomy for kidney cancer treatment, accurate segmentation of the kidney tumor is crucial for surgical planning, as it provides essential information on the precise size and location of the tumor. However, it is challenging due to the tumor's similar intensity to surrounding organs and the variability in its location and size across patients. In this study, we propose a hybrid network that integrates a convolutional neural network and a transformer to capture both local and global features, aiming to improve the segmentation performance of kidney tumors. We validated our method through comparative experiments with UNETR++, outperforming it with a Dice Similarity Coefficient (DSC) of 78.54% and a precision of 85.0 7%. Moreover, in the analysis by tumor size, our method demonstrated improvements by reducing over-segmentation and outlier cases observed in UNETR++.

Quality Changes of Dried Lavers during Processing and Storage 2. Quality Stability of Roasted Lavers during Processing and Storage (김의 가공 및 저장중의 품질변화 2. 배소김의 가공 및 저장중의 품질안정성)

  • LEE Kang-Ho;SONG Seung-Ho;JEONG In-hak
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.6
    • /
    • pp.520-528
    • /
    • 1987
  • Quality stability of roasted lavers during heat treatment and storage was investigated measuring the changes in pigments including chlorophyll a, carotenoids and biliproteins, fatty acids and free amino acids as the major quality factors. In roasting of fried lavers, carotenoids were found to lie more stable than chlorophyll a, and biliproteins were most heat labile. The overall heat stability of the pigments depended upon heating time and temperature. Chlorophyll a and carotenoids were retained more than $90\%$ in the casts of roasting for 90 min. at $60^{\circ}C;\;60min.\;at\;80^{\circ}C;\;10\;min.\;at\;100^{\circ}C;\;or\;5min.\;at\;150^{\circ}C$ while biliproteins remained about $70\%$. The lipids of dried lavers including polyunsaturated fatty acids appeared rather heat stable when compared to the stability of pigments under the same conditions of roasting. Spray of sesame oil or seasoning solutions on the surface of lavers after roasting seemed desirable for stabilizing pigments and free amino acids during storage particularly at low water activity. And that was also benefit for the protection of polyenoic fatty acids from rapid progress of oxidation during storage. Free amino acids were reduced fast during roasting, especially most of threonine and glycine while glutamic acid was rapidly lost during the storage.

  • PDF

A Prediction on Indoor Contaminant Diffusion Characteristics of a Training Ship by Mechanical Ventilation System (기계식 환기시스템에 의한 선내 오염물질 확산 특성 예측)

  • Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1124-1131
    • /
    • 2011
  • This study performed the prediction about the indoor contaminant's diffusion characteristics which can be affected by the mechanical ventilation system on a training ship. The results are as followings. It is clear that the contaminants are spread to most of the indoors, regardless of the contamination beginning zone. About 65~100 minutes later, the contaminant densities of whole indoor zones are evaluated as clean. Comparing the contamination beginning zone being located at higher deck(scenario A) to the contamination beginning zone being located at lower deck(scenario B), although the contaminant density by scenario A is 10 times higher than that by scenario B, the number of contaminated zones are 50% less. The contaminant densities are evaluated as to be rapidly decreased when the outside air induction ratio against design volume is over 75%.

Prediction of Sorption Characteristics by Mass Balance Concept (함량비례 개념에 의한 수분흡습 특성의 예측)

  • Yoon, Heeny H.N.;Kim, H.;Shin, Y.D.;Yoo, M.Y.
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.77-81
    • /
    • 1986
  • The water sorption isotherms of individual insoluble components of corn starch, isolated soybean protein (ISP) and casein and their binary mixtures of corn starch-lSP and corn starch-casein were measured and analyzed. BET monolayer values and Smith plot parameters from the results of sorption isotherms were calculated by mass balance concept . The comparisons between experimental and predicted values resulted in an error of 2.29% for equilibrium moisture content and an error of 2.95% in monolayer value for the mixture 50% corn starch-50% ISP. On the other hand , for the mixture 50% corn starch-50% casein the errors were 2.66% and-5.34%, respectively.

  • PDF

New Packaging and Characteristics of PIN PD for CWDM Transmission (저밀도 파장분할 다중화용 PIN PD 제작 및 특성)

  • Kang, Jae-Kwang;Chang, Jin-Heyon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.323-330
    • /
    • 2005
  • We fabricate PIN PD (Positive Intrinsic Negative Photo-Diode) for CWDM optical repeater and optical transmission system, and analyze theoretically the characteristics to verify the capability of device fabricated. Furthermore, we integrate CWDM filter into PD package to enhance the cost and the performance when compared to the conventional system, in which CWDM filter and PD package are linked by optical fusion splicing. The integrated CWDM PD is fabricated by three steps as follows: CWDM filter design, PD packaging, and product assembly and test. The results of measurement for PD fabricated reveal 0.5 dB bandwidth of 17 nm, isolation over 60 dB at transmission port and over 20 dB at reflection port. Also, the IMD3 for wireless communication is over 63 dBc, and the responsivity of PD presents over 0.9 A/W for 20 samples of the total 23 PD. The total insertion loss reduces about 0.4${\~}$0.7 dB due to the integrated assembly of CWDM and PD.

  • PDF

High-Dose-Rate Brachytherapy for Uterine Cervical Cancer : The Results of Different Fractionation Regimen (자궁경부암의 고선량률 근접치료 : 분할선량에 따른 결과 비교)

  • Yoon, Won-Sup;Kim, Tae-Hyun;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.228-236
    • /
    • 2002
  • Purpose : Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. Methods and Materials : From November 1992 to March 1998, 224 patients with uterine conical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was $45\~54\;Gy$ (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. Results : The local control rate (LCR) at 5 years was $80\%$ in group A and $84\%$ in group B (p=0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was $60.9\%$ in group A and $76.9\%$ in group B (p=0.2557). In post-operative radiation therapy patients, LCR at 5 years was $92.6\%$ In group A and $91.6\%$ in group B (p=0.8867). The incidence of late complication was $18\%$ (22 patients) and $29.4\%$ (30 patients), of bladder complication was $9.8\%$ (12 patients) and $14.7\%$ (15 patients), and of rectal complication was $9.8\%$ (12 patients) and $21.6\%$ (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication (p=0.0405) (rectal complication, p=0.0147; bladder complication, p=0.115). The same result was observed in postoperative radiation therapy patients (p=0.0860) and radiation only treated patients (0=0.0370). Conclusion : For radiation only treated patients, a greater number of itemized studies on the proper fraction size of HDR brachytherapy, with consideration for stages and prognostic factors, are required. In postoperative radiation therapy, the fraction size of HDR brachytherapy did not have much effect on local control, yet the incidence of late complication increased with the elevation in fraction size. We suggest that HDR brachytherapy three times weekly with 3 Gy could be an alternative method of therapy.

Evaluation of In-Vitro Efficacy of Active Ingredients in Dentifrice Used for Different Treatment Times (치약용 약효제의 적용시간에 따른 실험실적 효능 연구)

  • Ahn, Jae-Hyun;Kim, Ji-Hye;Kim, Ji-Young
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.176-182
    • /
    • 2016
  • The purpose of this study was to evaluate the in-vitro efficacy of the active ingredients of dentifrice following treatment time. The whitening effect was evaluated by a change in lightness value relative to the contact time of hydrogen peroxide, by using artificially stained hydroxyapatite discs. The anti-calculus effect was assessed based on the amount of calcium eluted from the human dental calculus by sodium pyrophosphate. Remineralization was evaluated by the Vickers hardness test following the application of sodium fluoride to bovine enamel. In order to view dentinal tubules occlusion, the formation of insoluble calcium salts by bovine dentin specimens was observed using scanning electron microscopy. Change in lightness value (${\Delta}L$) was $5.50{\pm}1.51$ after 1 min of treatment, $5.73{\pm}0.43$ after 3 min, $8.64{\pm}0.24$ after 10 min, $18.93{\pm}0.76$ after 30 min, and $27.35{\pm}0.54$ after 60 min. The amount of calcium eluted from the human dental calculus was $4.23{\pm}0.14ppm$ after 1 min of treatment, $4.51{\pm}0.04ppm$ after 3 min, $12.12{\pm}0.16ppm$ after 10 min, $17.85{\pm}0.81ppm$ after 30 min, and $25.15{\pm}0.32ppm$ after 60 min. The Vickers hardness change value (${\Delta}VHN$) was $1.96{\pm}1.44$ after 1 min, $1.52{\pm}1.06$ after 3 min, $9.06{\pm}0.15$ after 10 min, $10.83{\pm}5.13$ after 30 min, and $12.55{\pm}2.09$ after 60 min. Partial dentinal tubules occlusion was observed at 10 min and complete occlusion was evident at 60 min. In summary, the use of patch type dentifrices for 10, 30, or 60 min were 1.57 to 8.26 times more effective than using the paste type dentifrices for 1 to 3 min. Based on these findings, it is reasonable to expect that the use of patch type dentifrices for 10 min would lead to remineralization, anti-calculus and dentinal tubules occlusion effects, and that use for 30 min would result in a whitening effect.