• Title/Summary/Keyword: 이복희

Search Result 459, Processing Time 0.039 seconds

Measurement of Impedance of the Grounding Grid using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스 측정)

  • 이복희;엄주홍;김교운
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.303-306
    • /
    • 2002
  • This paper presents a novel method for measuring the ground impedance in grounding systems. A square wave current was injected to the main grounding grid through auxiliary electrode, and the test current and ground potential rise(GPR) were measured using the band-pass filter. Ground impedance was calculated from the sinusoidal waveforms of the test current and GPR in frequency range of 20~2100Hz. Also the resistance and reactance component of ground impedance were analyzed.

  • PDF

최신 절연시스템과 내열특성에 대한 소고

  • 이복희;김정섭
    • 전기의세계
    • /
    • v.35 no.4
    • /
    • pp.254-258
    • /
    • 1986
  • 최근 고분자재료의 눈부신 발전은 전기기기의 절연에도 많은 향상을 가져왔다. 전기기기의 절연재료로는 기계적, 전기적, 화학적 성능이 우수한 합성수지재료가 많이 쓰이고 있다. 전기절연재료를 대별하여 보면 박막재료와 함침재료로 나눌 수 있으며, 박막재료에는 운모, 실리콘고무, 폴리아미드필름, 폴리아미드클로즈 등이 있으며, 바니쉬류에는 내열성이 우수한 실리콘계바니쉬와 무용제함침재료가 많이 사용된다. 전기기기의 기본 구성재료이며 기기의 성능 향상과 소형화, 경량화에 중요한 인자로 작용하는 전기절연재료인 박막재료와 함침재료의 조화로 구성되는 절연시스템의 열열화와 내열수명에 영향을 미치는 절연의 신뢰성에 대하여 알아본다.

  • PDF

고전압 측정기술

  • 길경석;이복희;하성철
    • 전기의세계
    • /
    • v.46 no.8
    • /
    • pp.41-46
    • /
    • 1997
  • 최근 가스절연변전소와 같은 컴팩트화된 전력설비의 사용으로 과도전압 및 충격전류의 측정시 오차를 유발시키고 장해를 가져오는 요인 중에서 가장 현저한 것은 전자계 현상이며, 이에 대한 대책과 장해의 제거방법이 검토되어야만 한다. 또한 전력기기의 사용 중에 발생되는 과도전압과 충격전류는 진행파로서 작용하여 발생지점과 측정위치에 따라 달라지므로 종래의 저항분압기, 용량성분압기로는 정확한 측정이 불가능하기 때문에 전기적 신호의 과도적 현상을 직접 감지할 수 있는 측정장치가 필요하다. 다음의 3가지 고전압 측정기술은 피측정대상에 따라 가장 적합하게 제안된 것으로 측정응답을 개선하고 전자계의 영향을 최소화함으로써 정확한 측정이 가능하다.

  • PDF

Measurement and Analysis for Electric Fields due to Lightning stepped leaders (뇌방전의 리더진전에 따른 전장파형의 측정과 분석)

  • Lee, B.H.;Jeang, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2164-2166
    • /
    • 1999
  • This paper is describes the measured electric field waveform radiated by lightning discharge. We have performed measurement and analysis of the electric fields associated with stepped leaders. Electric field measurement system was composed of hemisphere electric field sensor, measurement system of a distance from lightning strokes, automatical recording system, A/D board, personal computer etc. A/D board have high sampling time, high speed data processing, 8bit of resolution. Also, measured characteristics of stepped leaders radiated by were analyzed.

  • PDF

A study on the actualization of ultra-high vacuum system (초고진공시스템의 실현에 관한 연구)

  • 백용현;이복희;전덕규
    • Electrical & Electronic Materials
    • /
    • v.4 no.4
    • /
    • pp.312-321
    • /
    • 1991
  • 본 논문은 3단배기계의 구성으로 $10^{-7}$[Torr]이하의 진공도를 얻을 수 있는 초고진공시스템을 시제작하고 이에 대한 동적 특성과 유지 및 관리방법에 대하여 기술하였다. 초고진공배기계의 구성에 있어서는 진공재료와 부품의 선정, 펌프조합, 다단식 펌프조합, 탈가스처리와 잔류기체의 성분분석이 대단히 중요함이 밝혀졌다. 또한 진공용기의 내표면의 공기중에의 노출은 배기성능을 대단히 저하시키게 된다. 본 연구결과와 관련기술은 각종 실험장치의 배기계의 최적화 설계는 물론이고 다용도로 이용될 것이다.

  • PDF

Ground Potential Distribution Associated with the Buried Depth of Ground Rod (봉형 접지전극의 시설깊이에 따른 대지전위분포)

  • Lee, B.H.;Eom, J.H.;Ahn, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2068-2070
    • /
    • 2000
  • Ground potential rise is a vital part of personal safety, this paper presents the ground potential rise distribution induced by a ground rod. The experiments were conducted with the AC square wave currents according to the buried depth of ground rod. The ground potential is significantly varied in the vicinity of ground rod and the ground potential distribution is flat and few with increasing the buried depth of ground rod.

  • PDF