• Title/Summary/Keyword: 이론적 잠재량

Search Result 32, Processing Time 0.028 seconds

Estimation of Theoretical and Technical Potentials of Geothermal Power Generation using Enhanced Geothermal System (우리나라 EGS 지열발전의 이론적 및 기술적 잠재량 평가)

  • Song, Yoon-Ho;Baek, Seung-Gyun;Kim, Hyoung-Chan;Lee, Tae-Jong
    • Economic and Environmental Geology
    • /
    • v.44 no.6
    • /
    • pp.513-523
    • /
    • 2011
  • We estimated geothermal power generation potential in Korea through Enhanced Geothermal System (EGS) technology following the recently proposed protocol which was endorsed by international organizations. Input thermal and physical data for estimation are density, specific heat and thermal conductivity measurements from 1,516 outcrop samples, 180 heat production, 352 heat flow, and 52 mean surface temperature data. Inland area was digitized into 34,742 grids of $1'{\times}1'$ size and temperature distribution and available heat were calculated for 1 km depth interval from 3 km down to 10 km. Thus estimated theoretical potential reached 6,975 GW which is 92 times total generation capacity of Korea in 2010. Technical potential down to 6.5 km and considering land accessibility, thermal recovery ratio of 0.14 and temperature drawdown factor of $10^{\circ}C$ was 19.6 GW. If we disregard temperature drawdown factor, which can be considered in estimating economic potential, the technical potential increases up to 56 GW.

Resource Assessment of Theoretical Potential of Ocean Energy in Korea (국내 해양에너지 이론적 잠재량 산정 연구)

  • HWANG, SUJIN;JO, CHULHEE
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.5
    • /
    • pp.465-472
    • /
    • 2019
  • This paper describes the resource assessment of theoretical potential of ocean energy including tidal current energy, tidal range energy, wave energy and ocean thermal energy in Korea to provide reliable basis for feasible development plan of ocean energy. Because of different characteristics of each ocean energy resources, the resource assessment methods were established considering characteristics of each ocean energy resources. The coastal region of Korea has been divided into 10 regions. The results show that tidal current energy is abundant in Incheon-Gyunggi and Jeollanam-do and tidal range energy is abundant in Incheon-Gyunggi. And wave energy is abundant in Jeollanam-do, Jeju and Gyeongsangbuk-do and there is ocean thermal energy in Gangwon-do and Gyeongsangbuk-do.

Estimation of Potential Wood Supply by according to Geographical and Forest Management Conditions in Korea (지리 및 임업경영 여건을 고려한 유형별 목재공급 잠재량 추정)

  • Won, Hyun-Kyu;Jang, Kwang-Min;Kim, Youngh-Wan;Lee, Kyeong-Hak;Kim, Hyung-Ho
    • Journal of agriculture & life science
    • /
    • v.45 no.3
    • /
    • pp.35-41
    • /
    • 2011
  • The objective of this study was to estimate domestic potential wood supply according to geographical and forest management conditions. In order to separate available wood supply area, analysis was conducted by separating natural, theoretical, geographical and technical supply area. Natural supply area was separated by extract stocked land from forest using digital stock map. Theoretical, geographical and technical supply area was separated by considering protection area, slope, streamside and road. Growing stock was calculated by using species and age-class of digital stock map. Potential wood supply was estimated by calculating growing stock of technical supply area. The results of growing stock of each supply area was shown that growing stock was from 244,150 to 596,248 thousand $m^3$. According to the results of this study, it was found that potential wood supply are likely to be over- or underestimated depending on the considered level of geographical and forest management conditions. Provincial potential wood supply was highly ranked in order of Gyeongbuk, jeonnam, Gyeongnam and Gangwon province.

Assessment of Geothermal Power Generation Potential According to EGS Potential Protocol (EGS Potential Protocol에 따른 우리나라 지열발전 잠재량 산정)

  • Song, Yoonho;Baek, Seung-Gyun;Kim, Hyoung Chan;Lee, Tae Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.144-144
    • /
    • 2011
  • We have estimated power generation potential in Korea following the recently announced EGS protocol. According to the protocol, we calculated the theoretical potential first, which assumes 30 year operation, minimum temperature being surface temperature+$80^{\circ}C$, depth range being from 3 km to 10 km. In this new assessment the in-land area was digitized by 1' by 1' blocks, which is much finer than suggestion of the protocol (5'by 5'). Thus estimated theoretical potential reaches 6,975 GWe which is 92 times of the total power generation capacity in 2010. In the estimation of technical potential, we limited the depth range down to 6.5 km, assumed recovery factor as 0.14 and also counted for temperature drawdown factor of $10^{\circ}C$ following the protocol. Accessible in-land area excluding steep mountains, residence and industrial region, wet area and others covers 40.7% of total area. Finally, we could come up with 19.6 GWe for technical potential, which would be 56 GWe if we do not account for the temperature drawdown factor. These are important results in that we made the first potential assessment for geothermal power generation.

  • PDF

Assessment of Theoretical Annual Energy Production in the Coast of South Korea Using Tidal Current Energy Converters Utilizing Flow Induced Vibration (한국 해안에서 유동유발진동 현상을 이용한 조류에너지 발전기술의 이론적 연간 발전량 산정연구)

  • Kim, Eun Soo;Oh, Kwang Myung;Park, Hongrae
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • The Korean government is aiming to produce 20% of the electricity using renewable energy sources by 2030. Ocean renewable energy sources which are abundant in South Korea can do an important role to achieve the goal. This paper introduces a tidal current energy converter utilizing flow induced vibrations which can efficiently work even in the currents slower than 1.0m/s and suggests optimal designs of the tidal energy converter based on speeds of the tidal currents in seven different coastal regions in South Korea. Moreover, the theoretical annual energy production by the tidal converter is estimated at theses costal areas. The total amount of the annual energy production by the tidal energy converter is predicted as 221.77 TWh which is equivalent to 42.3% of the electric consumption of South Korea in 2013. The result shows that the tidal current energy converter can be an important role to achieve the goal of the Korean government.

PPS 분진폭발에 대한 잠재적 위험성에 관한 연구

  • Kang, Young-Gu;Kim, Hong;Cho, Myung-Ho
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.105-108
    • /
    • 1998
  • Dust explosion은 combustible solid의 미세한 입자가 공기 혹은 산소중에서 폭발범위의 농도에서 부유할 때 화염 혹은 spark 등의 에너지 공급에 의해 폭발하는 현상이며 plastic 공업, 금속분말, 유기약품, 무기약품, 안료, 농수산건조물 등에서 분체취급 분야의 확대 및 취급량의 증가에 따라 분진폭발의 잠재 위험성이 급증하고 있어 화학적 성질, 농도, 입경, 폭발 압력 등의 분진특성과 함께 분진폭발의 착화온도와 상한 및 하한 농도에 대해 이론 및 실험적으로 광범위하게 연구가 진행되어져 왔다. (중략)

  • PDF

Improving Potential Flood Damage for Basin Flood Mitigation Safety Level (유역 치수안전도를 위한 홍수피해잠재능의 개선)

  • Lee, Seung-Jong;Kim, Young-Oh;Lee, Jae-Hyung;Lee, Yoon-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.226-230
    • /
    • 2006
  • 홍수피해잠재능(Potential Flood Damage: PFD)은 면 개념을 도입함으로써 치수단위구역의 치수특성 및 사회경제적인 가치를 함께 평가할 수 있도록 고안된 지수로 이미 여러 유역에서 시행되고 있는 유역종합 치수계획 사업에서 사용되고 있으나, 몇 가지 중요한 문제점이 꾸준히 제기되어 왔다. 본 연구에서는 우선 다음과 같은 이론적 문제점을 검토하였다. PFD는 처음 제안될 당시 (이하 기존 PFD) '잠재성'과 '위험성'라는 두 가지 요소가 곱해지는(multiplicative) 형태로 구성된 후 '위험성' 요소 안에 '가능성'과 '방어능력'이 더해지는 (additive) 형태를 취하고 있었다. 그러나 본 연구에서는 (이하 수정 PFD) '피해대상', '피해가능성', 그리고 '방어취약성'이 모두 곱해져야 이론적으로 타당함을 제시하였다. 기존 PFD는 '방어취약성'이 0의 값, 즉 홍수에 대한 완전방어를 의미하는 값에 가까워져도 PFD 값이 0에 수렴하지 않는 반면, 수정 PFD는 위의 경우 홍수 피해잠재능이 0에 수렴하는 것을 요소별 시나리오 모의를 통해서 확인할 수 있었다. 두 번째로 본 연구에서는 PFD를 이용하여 유역의 목표치수안전도 설정 방안을 제시하였다. PFD의 물리적인 의미가 무차원화 된 피해량 임을 전제로, 피해대상으로부터 목표방어율을 설정한 후 이에 해당하는 목표방어취약성을 계산하는 절차를 전개하였다. 추후 이 방법을 실제 자료에 적용하여 검증하는 연구가 이어져야 할 것이다.

  • PDF

Evaluation of Wind Turbine Efficiency of Haengwon Wind Farm in Jeju Island based on Korean Wind Map (풍력-기상자원지도에 기반한 제주 행원 풍력발전단지 효율성 평가)

  • Byon, Jae-Young;Kang, Mi-Sun;Jung, Hyun-Sook
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.633-644
    • /
    • 2013
  • This study evaluates wind farm efficiency at Haengwon in Jeju Island. The actual energy production at Haengwon wind farm is compared with the estimated energy production based on Korean wind map which is developed at the National Institute of Meteorological Research/KMA. The validation of wind map at Gujwa located near the Haengwon wind farm shows that the wind speed is overestimated. The diurnal variation of wind speed shows a maximum value in the afternoon due to the effect of sea-land breeze. The ratio of the actual energy production at Haengwon wind farm and the estimated energy production based on the Korean wind map is 24.8%, while the distribution of energy frequency is similar each other. The difference of energy production is caused by mechanical error of the turbine and the overestimation of the simulated wind map. This study will contribute to the repowering of turbines for improving the efficiency of wind farm in the future.

A Study on the Utilization of potential heat sources for Heat Pumps to District Heating System in Urban (도시 내 지역난방 Heat Pump용 잠재열원 이용에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.841-855
    • /
    • 2018
  • The purpose of this study is to estimate the available potential heat source for heat pump in the district heating supply area in the city. Unused energy potentials were estimated and integrated based on open source based data. In particular, geographical spatial analysis of recoverable heat energy density and heat demand in the heat source area of large retailers and public sauna facilities in the DH network located in the southern part of the metropolitan area (Pyeongtaek-si) was conducted. As a result of the study, the DH network area had a total potential energy of 1,741.7 toe/year for the two heat sources of large retailers and public saunas. It is estimated that 1,006.9 toe/year, which is 57.8% of the total, can be linked to the district heating. The large retailers showed a positive correlation with the floor area and energy use of 0.4937. The recoverable energy intensity was estimated to be $0.0017toe/m^2$ per unit area and $0.0069tCO_2/m^2$ for greenhouse gas emissions. In addition, public saunas were analyzed by comparing the empirical case with the theoretical calculation, and it was estimated that energy conservation estimate of 80% was $0.0315toe/m^2$ per bath area and $0.1183tCO_2/m^2$ for greenhouse gas emissions. The total potential energy amount of this area was positively correlated with the heat demand of apartment house by administrative district, and it was confirmed that it had a relatively high potential energy especially in traffic and commercial center.

방폭형 진동밀의 설계 및 제작

  • 조명호;강영구
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.61-64
    • /
    • 2002
  • Dust explosion은 combustible solid의 미세한 입자가 공기 혹은 산소중에서 폭발범위의 농도에서 부유할 때 화염 혹은 Spark 등의 에너지 공급에 의해 폭발하는 현상이며 plastic 공업, 금속분말, 유기약품, 무기약품, 안료, 농수산건조물 등에서 분체취급 분야의 확대 및 취급량의 증가에 따라 분진폭발의 잠재 위험성이 급증하고 있어 화학적 성질, 농도, 입경, 폭발 압력 등의 분진특성과 함께 분진폭발의 착화온도와 상한 및 하한 농도에 대해 이론 및 실험적으로 광범위하게 연구가 진행되어져 왔다.(중략)

  • PDF