• Title/Summary/Keyword: 이두이노

Search Result 2,101, Processing Time 0.033 seconds

Studies on the Electrochemical Behavior of Heavy Lanthanide Ions and the Synthesis, Characterization of Heavy Metal Chelate Complexes(II). Synthesis and Characterization of Eight Coordinate Tungsten(IV) and Cerium(IV) Chelate Complex (무거운 란탄이온의 전기화학적 거동 및 중금속이온의 킬레이트형 착물의 합성 및 특성에 관한 연구(제2보). 8배위 텅스텐(IV)과 세륨(IV)의 킬레이트형 착물의 합성 및 특성)

  • Kang, Sam Woo;Chang, Choo Wan;Suh, Moo Yul;Lee, Doo Youn;Choi, Won Jong
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.41-49
    • /
    • 1992
  • An attempt was made to prepare two series of tetrakis eight-coordinate tungsten(IV) and cerium(IV) complexes containing the 5,7-dichloro-8-quinolinol(N:${\pi}$-acceptor atom, O:${\pi}$-donor atom) ligand. Tetrakis eight-coordinate tungsten(IV) complex of 2-mercaptopyrimidine(N:${\pi}$-acceptor atom, S:${\pi}$-donor atom) ligand have also been prepared. And the new series of mixed-ligand eight-coordinate tungsten(IV) complexes containing bidentate ligands 5,7-dichloro-8-quinolinol and 2-mercaptopyrimidine have been prepared, isolated by TLC and characterized. $W(dcq)_4$, $W(dcq)_3(mpd)_1$, $W(dcq)_2(mpd)_2$, $W(dcq)_1W(dcq)_3$ and $W(mpd)_4$ complexes of MLCT absorption band appeared to 710nm, 680nm, 625nm, 581nm, and 571nm(${\varepsilon}\;max={\sim}>{\times}10^4$) on low-energy respectively. The specific absorption wave length of $Ce(dcq)_4$ is appeared 520nm(${\varepsilon}\;max={\sim}>{\times}10^4$). The Chemical shift values by proton of coordinated position appeared to $W(dcq)_4$ [$H_2:8.9ppm$]; $W(dcq)_3(mpd)_1$ [$H_2:9.3$,$H_6:9.2ppm$]; $W(dcq)_2(mpd)_2$ [$H_2:9.7$,$H_6:8.95ppm$]; $W(dcq)_1(mpd)_3$ [$H_2:9.8$,$H_6:9.4ppm$]; $W(mpd)_4$ [$H_6:8.8ppm$]; $Ce(dcq)_4$ [$H_2:9.3ppm$] with $^1H$-NMR. The inertness of mixed-ligand eight coordinate tungsten(IV) complexes have been investigated by UV-Vis. spectroscopic method in dimethylsulfoxide at $90^{\circ}C$. The inertness of $W(dcq)_n(mpd)_{4-n}$ complexes showed the following order, $W(dcq)_3(mpd)_1;k_{obs.}=3.8{\times}10^{-6}$ > $W(mpd)_4;k_{obs.}=6.0{\times}10^{-6}$ > $W(dcq)_4;k_{obs.}=6.4{\times}10^{-6}$ > $W(dcq)_2(mpd)_2;k_{obs.}=7.0{\times}10^{-6}$ > $W(dcq)_1(mpd)_3;k_{obs.}=1.7{\times}10^{-5}$, which showed the inertness until 16days, 10days, 9days, 8days, and 4days. The $W(mpd)_4$ is very inert as $k_{obs.}=3.6{\times}10^{-6}$(16days) in xylene at $90^{\circ}C$ and $k_{obs.}=6.0{\times}10^{-6}$(10days) in DMSO at $90^{\circ}C$.

  • PDF

Factors Affecting Pregnancy Rates on Transfer of Pronuclear Microinjected Embryos in Korean Black Goats (전핵 미세 주입법으로 생산된 한국흑염소 수정란의 이식 조건이 수태율에 미치는 영향)

  • Choi, Y.S.;Shin, H.G.;Jang, S.K.;Yang, H.S.;Lee, O.K.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2007
  • This study was investigated factors affecting the pregnancy rates after transfer of pronuclear microinjected embryos for the production of transgenic Korean black goats. Embryo transfer was carried out in 343 recipient Korean black goats from September 1999 to June 2000. Estrus was induced by the insertion of intravaginal progesterone devices $CIDR^(R)$ for 2 weeks. A single injection of 400 IU equine chorionic gonadotropin was administered at 48h before $CIDR^(R)$ removal to increase the proportion of does cycling and ovulation rate. Good quality embryos were prepared by microinjection of DNA into the pronuclei of fertilized goat oocyte and cultured in vitro. Pronuclear microinjected $1{\sim}8$ cell stage embryos were surgically transferred into the oviducts of the recipient at day 4 or 5 following $CIDR^(R)$ removal, and morula to blastocyst stage embryos were surgically transferred into uterus at day 9. Pregnancy was diagnosed by transrectal ultrasound scanning at $20{\sim}30d$ and 8 weeks following embryo transfer. The pregnancy rate was affected by several factors, such as estrus induction, the number of previous transfer, transfer site, stage of CL (corpus luteum), the number of recipient CL, stage of embryos and the number of transferred embryo. The pregnancy rate was significantly higher in recipients that came into estrus naturally than recipients that induced to come into estrus with $CIDR^(R)$(59.1% vs. 36.8%; P<0.05). The pregnancy rate was higher when the embryos were transferred into the left oviduct than transferred into the right oviduct (42.9% vs. 35.3%; P<0.05). The pregnancy rate of recipients with $CH_1$ (early) stage corpus hemorrhagicum in ovary was hi틴or than recipient with $CH_3$ (late) stage hemorrhagicum (47.5% vs. 17.9%; P<0.01). Higher pregnancy rates were obtained by transfer of 1-cell stage embryos into oviduct while late blastocysts (51.6% vs. 66.7%; P<0.01) into uterus. The pregnancy rates when 3 embryos were transferred to recipients were significantly higher than when 2 embryos we.e transferred (47.6% vs. 27.0%; P<0.05). Although there were no significant difference among the group, adhesion of reproductive organs, uterine size, ovulation rate of recipients, presence of large follicle and difficulty of transfer affected pregnancy rate of recipient. Higher pregnancy rates were obtained in the recipients with $8{\sim}15m$ diameter uterine horn as compared to the recipients with <5m diameter or >20mm diameter uterine hem (38.9%, 20% vs. 18.2%), in the recipients with large follicle in the ovulated ovary ipsilaterally (53.6% vs. 37.1%) and in the transfer which was carried out easily (39.2% vs. 27.8%, 0%). In conclusion, the high rate of pregnancy was achieved following transfer of pronuclear microinjected embryos when three or four 1-cell stage embryos were transferred into oviduct with $CH_1$ stage corpus hemorrhagicum in the ovary of recipient which came into estrus naturally.

The Role of Postoperative Adjuvant Radiotherapy in Resected Esophageal Cancer (식도암에서 근치적 절제술 후 방사선치료의 역할)

  • Lee Chang Geol;Kim Choong Bae;Chung Kyung Young;Lee Doo Yun;Seong Jinsil;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.316-322
    • /
    • 2002
  • Objective : A retrospective study was peformed to evaluate whether postoperative adjuvant radiotherapy can improve survival and decrease recurrence as compared with surgery alone in resected esophageal cancer. Materials and Methods : From Jan. 1985 to Dec. 1993, among 94 esophageal cancer Patients treated with surgery, fifty-one patients were included in this study. Transthoracic esophagectomy was peformed in 35 patients and transhiatal esophagectomy in 16. Postoperative adjuvant radiotherapy was peformed 4 weeks after surgery in 26 among 38 patients in stage II and III. A total dose of $30\~60\;Gy$ in 1.8 Gy daily fraction, median 54 Gy over 6 weeks, was delivered in the mediastinum+both supraclavicular lymph nodes or celiac lymph nodes according to the tumor location. Forty-seven patients$(92\%)$ had squamous histology. The median follow-up period was 38 months. Results : The overall 2-year and 5-year survival and median survival were $56.4\%,\;36.8\%$ and 45 months. Two-year and 5-year survival and median survival by stage were $92\%,\;60.3\%$ for stage I, $63\%,\;42\%$ and 51 months for stage II and $34\%,\;23\%$ and 19 months for stage III (p=0.04). For stage II and III patients, 5-year survival and median survival were $22.8\%$, 45 months for the surgery alone group and $37.8\%$, 22 months for the postoperative RT group (p=0.89). For stage III patients, 2-year survival and median survival were $0\%$, 11 months for the surgery alone group and $36.5\%$, 20 months for the postoperative RT group (p=0.14). Local and distant failure rates for stage II and III were $50\%,\;16\%$ for the surgery alone and $39\%,\;31\%$ for the postoperative RT group. For N1 patients, local failure rate was $71\%$ for the surgery alone group and $37\%$ for the postoperative RT group (p=0.19). Among 10 local failures in the postoperative RT group, in-field failures were 2, marginal failures 1, out-field 5 and anastomotic site failures 2. Conclusion : There were no statistically significant differences in either the overall survival or the patterns of failure between the surgery alone group and the postoperative RT group for resected stage II and III esophageal cancer. But this study showed a tendency of survival improvement and decrease in local failure when postoperative RT was peformed for stage III or N1 though statistically not significant. To decrease local failure, a more generous radiation field encompassing the supraclavicular, mediastinal, and celiac lymph nodes and anastomotic site in postoperative adjuvant treatment should be considered.

Comparison of CT based-CTV plan and CT based-ICRU38 plan in brachytherapy planning of uterine cervix cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거할 치료계획의 비교)

  • Shim JinSup;Jo JungKun;Si ChangKeun;Lee KiHo;Lee DuHyun;Choi KyeSuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.9-17
    • /
    • 2004
  • Purpose : Although Improve of CT, MRI Radio-diagnosis and Radiation Therapy Planing, but we still use ICRU38 Planning system(2D film-based) broadly. 3-Dimensional ICR plan(CT image based) is not only offer tumor and normal tissue dose but also support DVH information. On this study, we plan irradiation-goal dose on CTV(CTV plan) and irradiation-goal dose on ICRU 38 point(ICRU38 plan) by use CT image. And compare with tumor-dose, rectal-dose, bladder-dose on both planning, and analysis DVH Method and Material : Sample 11 patients who treated by Ir-192 HDR. After 40Gy external radiation therapy, ICR plan established. All the patients carry out CT-image scanned by CT-simulator. And we use PLATO(Nucletron) v.14.2 planing system. We draw CTV, rectum, bladder on the CT image. And establish plan irradiation-$100\%$ dose on CTV(CTV plan) and irradiation-$100\%$ dose on A-point(ICRU38 plan) Result : CTV volume($average{\pm}SD$) is $21.8{\pm}26.6cm^3$, rectum volume($average{\pm}SD$) is $60.9{\pm}25.0cm^3$, bladder volume($average{\pm}SD$) is $116.1{\pm}40.1cm^3$ sampled 11 patients. The volume including $100\%$ dose is $126.7{\pm}18.9cm^3$ on ICRU plan and $98.2{\pm}74.5cm^3$ on CTV plan. On ICRU planning, the other one's $22.0cm^3$ CTV volume who residual tumor size excess 4cm is not including $100\%$ isodose. 8 patient's $12.9{\pm}5.9cm^3$ tumor volume who residual tumor size belows 4cm irradiated $100\%$ dose. Bladder dose(recommended by ICRU 38) is $90.1{\pm}21.3\%$ on ICRU plan, $68.7{\pm}26.6\%$ on CTV plan, and rectal dose is $86.4{\pm}18.3\%,\;76.9{\pm}15.6\%$. Bladder and Rectum maximum dose is $137.2{\pm}50.1\%,\;101.1{\pm}41.8\%$ on ICRU plan, $107.6{\pm}47.9\%,\;86.9{\pm}30.8\%$ on CTV plan. Therefore CTV plan more less normal issue-irradiated dose than ICRU plan. But one patient case who residual tumor size excess 4cm, Normal tissue dose more higher than critical dose remarkably on CTV plan. $80\%$over-Irradiated rectal dose(V80rec) is $1.8{\pm}2.4cm^3$ on ICRU plan, $0.7{\pm}1.0cm^3$ on CTV plan. $80\%$over-Irradiated bladder dose(V80bla) is $12.2{\pm}8.9cm^3$ on ICRU plan, $3.5{\pm}4.1cm^3$ on CTV plan. Likewise, CTV plan more less irradiated normal tissue than ICRU38 plan. Conclusion : Although, prove effect and stability about previous ICRU plan, if we use CTV plan by CT image, we will reduce normal tissue dose and irradiated goal-dose at residual tumor on small residual tumor case. But bigger residual tumor case, we need more research about effective 3D-planning.

  • PDF

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

A Study on the Treatment of Combine Electron Beam in the Treatment of Breast Cancer Tumor Bed (유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

The Evaluation of Non-Coplanar Volumetric Modulated Arc Therapy for Brain stereotactic radiosurgery (뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Doo Sang;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.9-16
    • /
    • 2018
  • Purpose : Brain Stereotactic Radiosurgery can treat non-invasive diseases with high rates of complications due to surgical operations. However, brain stereotactic radiosurgery may be accompanied by radiation induced side effects such as fractionation radiation therapy because it uses radiation. The effects of Coplanar Volumetric Modulated Arc Therapy(C-VMAT) and Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT) on surrounding normal tissues were analyzed in order to reduce the side effects caused fractionation radiation therapy such as head and neck. But, brain stereotactic radiosurgery these contents were not analyzed. In this study, we evaluated the usefulness of NC-VMAT by comparing and analyzing C-VMAT and NC-VMAT in patients who underwent brain stereotactic radiosurgery. Methods and materials : With C-VMAT and NC-VMAT, 13 treatment plans for brain stereotactic radiosurgery were established. The Planning Target Volume ranged from a minimum of 0.78 cc to a maximum of 12.26 cc, Prescription doses were prescribed between 15 and 24 Gy. Treatment machine was TrueBeam STx (Varian Medical Systems, USA). The energy used in the treatment plan was 6 MV Flattening Filter Free (6FFF) X-ray. The C-VMAT treatment plan used a half 2 arc or full 2 arc treatment plan, and the NC-VMAT treatment plan used 3 to 7 Arc 40 to 190 degrees. The angle of the couch was planned to be 3-7 angles. Results : The mean value of the maximum dose was $105.1{\pm}1.37%$ in C-VMAT and $105.8{\pm}1.71%$ in NC-VMAT. Conformity index of C-VMAT was $1.08{\pm}0.08$ and homogeneity index was $1.03{\pm}0.01$. Conformity index of NC-VMAT was $1.17{\pm}0.1$ and homogeneity index was $1.04{\pm}0.01$. $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$ of the brain were $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$ and $4.03{\pm}3.43cc$ in the C-VMAT and $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$. Conclusions : The maximum dose, conformity index, and homogeneity index showed no significant difference between C-VMAT and NC-VMAT. $V_2$ to $V_{18}$ of the brain showed a difference of at least 0.5 % to 48 %. $V_{19}$ to $V_{24}$ of the brain showed a difference of at least 0.4 % to 4.8 %. When we compare the mean value of $V_{12}$ that Radione-crosis begins to generate, NC-VMAT has about 12.2 % less amount than C-VMAT. These results suggest that if NC-VMAT is used, the volume of $V_2$ to $V_{18}$ can be reduced, which can reduce Radionecrosis.

  • PDF

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.

  • PDF

Biliary Atresia in Korea - A Survey by the Korean Association of Pediatric Surgeons - (담도폐색증 - 대한소아외과학회회원 대상 전국조사 -)

  • Choi, Kum-Ja;Kim, S.C.;Kim, S.K.;Kim, W.K.;Kim, I.K.;Kim, J.E.;Kim, J.C.;Kim, H.Y.;Kim, H.H.;Park, K.W.;Park, W.H.;Song, Y.T.;Oh, S.M.;Lee, D.S.;Lee, M.D.;Lee, S.K.;Lee, S.C.;Jhung, S.Y.;Jhung, S.E.;P.M., Jung;S.O., Choi;Choi, S.H.;Han, S.J.;Huh, Y.S.;Hong, C.;Hwbang, E.H.
    • Advances in pediatric surgery
    • /
    • v.8 no.2
    • /
    • pp.143-155
    • /
    • 2002
  • A survey on biliary atresia was made among 26 members of the Korean Association of Pediatric Surgeons. The members were required to complete a questionnaire and a case registration form for each patient during the twentyone-year period of 1980-2000. Three hundred and eighty patients were registered from 18 institutions. The average number of patients per surgeon was one to two every year. The male to female ratio was 1:1.3. The age of patients on diagnosis with biliary atresia was on average $65.4{\pm} 36.2$ days old. The national distribution was 32.8% in Seoul, 25.3% in Gyoungki-Do, 21.6% in Gyoungsang-Do, 9.27% in Choongchung-Do, etc. in order. The most common clinical presentation was jaundice (98.4%) and change of stool color (86.2%) was second. Two hundred eighty (74.7%) of 375 patients were operated by 80 days of age. Three hundred thirty six (9 1.9%) of 366 patients were operated on by the original Kasai procedure, and 305 (84.3%) of 362 patients were observed by bile-drainage postoperatively. The overall postoperative complication rate was 18.5% and the overall postoperative mortality rate was 6.8%. The associated anomalies were observed in 72 cases (22.5%). One hundred ninty five (64.7%) of 302 patients have been alive in follow-up and 49 (25.1%) have survived over 5 years without problem after operation. Ascending cholangitis, varices and ascites affected survival significantly, and the important long-term prognostic factor was the occurrence of complications.

  • PDF