• Title/Summary/Keyword: 이격 거리

Search Result 691, Processing Time 0.029 seconds

Large Fire Forecasting Depending on the Changing Wind Speed and Effective Humidity in Korean Red Pine Forests Through a Case Study (사례분석을 통한 소나무림에서의 풍속과 실효습도 변화에 의한 대형산불 위험예보)

  • KANG, Sung-Chul;WON, Myoung-Soo;YOON, Suk-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.146-156
    • /
    • 2016
  • In this study, we developed a large fire forecasting system using critical weather conditions, such as strong winds and effective humidity. We incorporated information on forest type prior to large fires using an incident case study. The case study includes thirty-seven large fires covering more than 100 ha of damaged area over the last 20 years. Dangerous large fire regions were identified as areas of more than 30 ha of Korean red pine and the surrounding two kilometers. Large fires occur when wind speeds average 5.3 m/s with a maximum of 11.6 m/s and standard deviation of 2.5 m/s. Effective humidity for large fires average 30% with a minimum of 13% and standard deviation of 14.5%. In dangerous Korean red pine stand areas, the large fire 'Watch' level is issued when effective humidity is 30-45% for more than two days and average wind speed is 7-10 m/s. The 'Warning' level is issued when effective humidity is less than 30% for more than two days and average wind speed is more than 11 m/s. Therefore, from now on, the large fire forecasting system can be used effectively for forest fire prevention activities based on a selection and concentration strategy in dangerous large fire regions using severe weather conditions.

A Study on Information Efficiency in Stock Selection by Various Investor Type (투자자집단별 선택적 종목거래활동의 정보효율성 검증)

  • Lee, Sung-Hoon;Lee, Jung-Jin;Lee, Jae-Hyun
    • Management & Information Systems Review
    • /
    • v.34 no.1
    • /
    • pp.65-80
    • /
    • 2015
  • In previous studies concerning turnover, they argue individual stock's turnover must be identical to market portfolio's turnover under one condition where 2 funds separation theorem holds. In this kind of world, all market participants hold and trade the same portfolio and this should be only market portfolio. If one's trading portfolio's shape is different from market portfolio's, this would mean he or she has an advantage over others in information and this kind of information would be private. In accordance with this theory, we develop a metric which measures how far one's trading portfolio from market's and name it as Stock Selection by Investor(SSI). We apply this measurement to the various types of investor groups classified as individual, institutional and foreign who participate in Korea stock market. To test the validity of measure, we regress price ratio on this measurement using SUR method. As a result, individual investor group shows large number in SSI, but the coefficient in regression is not significant and economically meaningless. In case of institutional investor group, the coefficient proves to be significantly negative. We can infer from this fact that their trading is somehow far from informed trading. Stock selection activity by foreign investor groups proves to be informed trading by showing significantly positive coefficient and the magnitude of coefficient is economically meaningful, especially in sell activity.

  • PDF

Relationship between Population of Wintering Whopper Swan (Cygnus cygnus) and Bridge Spacing in the Lower Nakdong River, Korea (낙동강하류 교량간격에 따른 큰고니(Cygnus cygnus) 월동개체수 차이 연구)

  • Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2020
  • The purpose of this was to examine the differences of large whopper swan (Cygnus cygnus) in wintering habitat preference among bridge sections of the lower Nakdong River of the Nakdong River Estuary, the largest whopper swan's wintering habitat in Korea. This species is designated and protected as Natural Monument in Korea. The survey was conducted in six time-series during the 2018~2019 wintering season, and it found up to 500 whopper swans were wintering in the lower Nakdong River. For the survey, a seven sections were set up based on the bridges across the river. Whopper swans were rarely observed in five narrow sections where the distance between bridges was less than 2 km. The stable population of the whopper swan was observed only in two broader sections where the distance between bridges was is over 4 km. As these sections were relatively little affected by artificial interference, the distance from the mouth of the Nakdong River was not a factor. Securing a stable space is considered as one of the most important factors for wintering of whopper swans, which are an endangered species. The survey results indicate that the distance between bridges should be at least 4 km to secure the whopper swan's stable habitat. These results are expected to be a reference to the development or restoration of the river ecosystems, especially bridge construction.

Enhanced WMAN System based on Region and Time Partitioning D-TDD OFDM Architecture (영역/시간 세분화 D-TDD OFDM 구조에 기반한 새로운 WMAN 시스템 구조 설계)

  • Kim, Mee-Ran;Cheong, Hee-Jeong;Kim, Nak-Myeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.68-77
    • /
    • 2006
  • In accommodating the asymmetric traffic for future wireless multimedia services, the dynamic time division duplexing (D-TDD) scheme is considered as one of the key solutions. With the D-TDD mode, however, the inter-BS and inter-MS interference is inevitable during the cross time slot (CTS) period, and this interference seriously degrades the system performance. To mitigate such interference, we propose a region and time partitioning D-TDD architecture for OFDM systems. Each time slot in the CTS period is split into several minislots, and then each cell is divided into as many regions as the number of minislots per time slot. We then assign the minislots only to the users in its predefined corresponding region. On top of such architecture which inherently separates the interfering entities farther from each other, we design a robust time slot allocation scheme so that the inter-cell interference can be minimized. By the computer simulation, it has been verified that the proposed scheme outperforms the conventional time slot allocation methods in both the outage probability and the bandwidth efficiency.

Study on Applicability of Simultaneous Multiple Compaction Grouting Method in Soft Clay Ground (점성토 연약지반에서의 다중 동시주입 컴팩션 그라우팅 공법 적용성 연구)

  • Lee, Hyobum;Jung, Hyun-Seok;Jung, Eui-Youp;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.779-788
    • /
    • 2019
  • The compaction grouting method is one of the conventional ground improvement methods, which consolidates and compacts the surrounding ground through the injection of grout materials with low mobility. Injecting the grout into the ground can improve the soil properties, as well as form a composite of soil-grout columns. However, the conventional grout pumping is not applicable to handle multiple injection holes at the same time, which may diminish its constructability when the construction time is not enough. This paper proposes a simultaneous multiple compaction-grouting method using a new pump system developed to cover up simultaneously three injection holes at a time. Field injection tests with a single injection hole and with triangular arrangement of injection holes were conducted to evaluate the applicability of the proposed method to soft clay ground. In addition, a series of standard penetration tests (SPTs) were performed to assess the efficiency of each arrangement in improving the soft ground. It is noted from the in-situ test results that the interval distances between injection holes and the elapse time for ground stabilization are the crucial factors governing the applicability of the simultaneous multiple compaction-grouting method to improve the soft clay ground.

Value Assessment for Inland Wetlands according to Ecological Geographic Distribution (생태지리적 입지에 따른 내륙습지 가치평가)

  • Lee, Jung-Hwan;Im, Ran-Young;Lee, Gwan-Gyu;Park, Hyun-Chul
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.456-464
    • /
    • 2016
  • Korea established an inventory of 1,916 sites of inland wetlands during a nationwide investigation from 2000 to 2010. If inland wetlands is included in or near various protected areas designated by the government, it can be selected as a wetland to be managed with priority. This study evaluated the aspect of management of inland wetlands by analyzing the correlation between locations of national protected areas and inland wetlands. As a result, it was shown that a considerable percentage of current inland wetland was located in areas that were designated and managed as protected areas by the government, as they had a high value of natural environment protection (527 sites, 31.61 %). When the range was widened to a radius of 1 km for protected areas, 959 sites were included and 57.53 % of sites were located in or nearby the protected areas. Among them, 46.79 % of sites were distributed up to or within a 1 km radius of waterside areas and rivers; it accounted for 81.33 % of wetlands located in protected areas. Therefore, it was found that locations of current inland wetlands were mostly in contact with rivers. The results of overlay analysis were classified into high, medium and low; the correlation of location with inland wetlands was analyzed through the analysis of separation distance of various protected areas. The number of wetlands located in areas of a 'high' value of protection was 998 (59.87 %); 289 sites (17.34 %) were distributed in areas of a 'low' value of protection. This implies that these wetlands are located in artificial areas and are more exposed to environmental pressures. Thus, these wetlands could be determined as inland wetlands, which we considered for the establishment of measures to prevent damage.

Spatial Assessment of Effects of Near-Stream Groundwater Pumping on Streamflow Depletion (하천변 지하수 양수로 인한 하천수 감소 영향의 공간적 평가 - 죽산천 유역을 중심으로 -)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon;Lee, Min Ho
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.545-552
    • /
    • 2015
  • The objective of this study is to spatially assess the streamflow depletion due to groundwater pumping near the main stream of Juksanchoen watershed. The surface water and groundwater integrated model, SWAT-MODFLOW, in this study, was used to simulate streamflow responses to each groundwater pumping from wells located within 500m from the stream. The simulated results showed that the streamflow depletion rate divided by the pumping rate for each well location ranges from 20% to 96%. In particular, the streamflow depletion exceeds 60% of pumping rate if the distance between stream and well is lower than 100 m, hydraulic diffusivity is higher than $500m^2/d$, and streambed hydraulic conductance is above 25m/d. The simulated results were also presented in the form of spatial distribution maps that indicate the fraction of the well pumping rate in order to show the effect of a single well more comprehensively and easily. From the developed areal distribution of stream depletion, higher and more rapid responses to pumping occur near middle-downstream reach, and the spatially averaged percent depletion is about 66.7% for five years of pumping. The streamflow depletion map can provide objective information for the near-stream groundwater permission and management.

Distribution Patterns and Characteristics of Plant Species by Human Impact in Urban Areas1a - Case Study of Cheon-ju - (인간의 영향에 따른 도시지역 식물종의 분포 패턴 및 특성)

  • Choi, Il-Ki;Lee, Eun-Heui
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.5
    • /
    • pp.505-513
    • /
    • 2008
  • The purpose of this study is to analyze the distribution patterns and characteristics of plant species by human impact in urban areas. In order to achieve a comprehensive data acquisition of all autogenously introduced vascular plant species occurring in the city of Cheon-ju, this study made an analysis of 106 sample plots, each with a size of one hectare, These sample plots were selected to represent the typical land-use patterns within the city of Cheon-ju and to cover the various distances from the city center. Species richness, patterns of life forms, and the percentage of non-native species were analyzed in relation to the degree of hemeroby of the sample plots. It was found that the species number appeared the largest in sites that were moderately influenced. This result corresponds to the intermediate disturbance hypothesis that moderate disturbance leads to an increase in species richness. The flora of sites which were subject to the highest level of human impact, was characterized by a high proportion of annual species and non-native species. In addition, some species were divided into three groups with similar distribution corresponding to land-use type and urban zone: urbanophobic (e.g. Indigofera kirilowii, Prunus sargentii, Rhus trichocarpa), urbanoneutral (e.g. Commelina communis, Erigeron annuus, Metaplexis japonica) and urbanophilus (e.g. Euphorbia supina, Senecio vulgaris, Taraxacum officinale).

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

Radiated Emission of Electrical Fast Transient/Burst Signal and Its Countermeasures (전기적으로 빠른 과도현상/버스트 신호의 복사방출과 대책)

  • Park, Soo Hoon;Kim, Dong Il;Park, Youn Joon;Nah, Seung Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.291-298
    • /
    • 2016
  • In this paper, we studied about the radiated emission of EFT(Electrical Fast Transient)/Burst signal, referenced IEC-61000-4-4 of the international EMC standard and its effect on EUT(Equipment Under the Test) when EFT/Burst signal (Conducted noise) induced on a power cable to EUT. Firstly, we set up test sample by the standard and +4 kV standard signal is induced by EFT/Burst signal generator with 1 m length power cable for 1 minute. Consequently, we found not only induced EFT/Burst signal along power line, but also directly radiated emission signal from EFT/Burst signal generator (Radiated emission noise of EFT/Burst). The radiated emission signal of EFT/Burst was 30 dB which is higher than limit of CISPR 22 which is international EMC standard. Moreover, we measured the electric field strength by changing distance from maximum radiated emission point to electric field strength tester. As a result, this electric field strength was 23 V/m which is higher than international EMC standard test level(CISPR 24). Therefore, it was confirmed that the probability of malfunction may be high when radiated emission of EFT/Burst noise exists near the EUT.