• Title/Summary/Keyword: 의치장착

Search Result 141, Processing Time 0.023 seconds

The use of implant-assisted removable partial denture in the partially edentulous maxilla with a few unilateral remaining teeth and implant overdenture in the mandible: A case report (상악 편측 소수 잔존치에서 임플란트 융합 국소의치와 하악 임플란트 피개의치의 수복 증례)

  • Yun, Yina;Kim, Hyun-Ah;Park, Sangwon;Park, Chan;Jang, Woohyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.515-522
    • /
    • 2021
  • Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.

Complete denture made with closed-mouth impression technique on severely atrophied edentulous jaw (하악 치조골이 심하게 위축된 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Lee, Suk-Hwan;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.195-202
    • /
    • 2019
  • At the department of prosthodontics, the elderly patients with severely atrophied alveolar ridge who have been wearing complete dentures for a long period frequently visit the clinic. In general, the open-mouth impression technique for manufacturing a mandibular complete denture to secure primary support on buccal shelf area has been prevalent. In addition, for securing retention and stability of mandibular denture, we should consider diagnosis, oral function, denture border, occlusal plane, teeth arrangement, and patient training, etc.. But in edentulous patients with severe alveolar bone atrophy, it may hardly secure retention and stability of mandibular complete denture. To promote these, some of clinicians are making an attempt manufacturing the mandibular complete dentures using closed-mouth impression technique based on several reports that compare various impression techniques including open-mouth and closed-mouth impression technique. This case report suggests closed-mouth impression technique may promote retention and stability of mandibular complete denture and compares between the two impression techniques clinically.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

Complete denture rehabilitation utilizing digital process: A case report (디지털 방식을 활용한 양악 총의치 수복 증례)

  • An, Yoojin;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.313-319
    • /
    • 2022
  • Complete dentures are one of the most basic treatment methods for the treatment of edentulous patients. The manufacturing process of traditional complete dentures goes through the steps of taking primary impressions, secondary impressions, jaw relation record, trying in wax denture, and final denture insertion. Multiple visits and complex manufacturing procedures are required, and errors may occur in each step. With the development of digital technology, manufacturing steps have been reduced by introducing digital technology to the denture treatment process. In the process of manufacturing dentures by introducing a digital process, a more precise work is possible using Computer-Aided Design, and it is possible to shorten the period of labor and reduce the number of visits. In this case, the anterior teeth arrangement of the patient's existing dentures was transferred to the final dentures using a digital method. After taking impression, try-in dentures were digitally fabricated and tried in the oral cavity to evaluate their retention in the oral cavity. Final dentures were manufactured by milling process. The number of visits was reduced, satisfactory retention and stability of dentures were obtained, and aesthetic recovery was achieved.

Fabrication of complete denture using CAD-based vertical dimension increase and monolithic disc: a case report (CAD를 이용한 수직 고경 증가와 monolithic disc를 사용한 총의치 수복 증례)

  • Hyeon, Kim;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.242-248
    • /
    • 2022
  • Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

Maxillary implant-supported fixed prosthesis engaged by distal-extension removable partial denture for 10 years: a case report (상악의 임플란트 고정성 보철물과 후방연장 국소의치를 이용하여 수복한 10년 경과 관찰 증례)

  • Ryu, Ri;Park, Yeon-Hee;Oh, Won-suk;Lee, Jung-Jin;Park, Ju-mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.121-127
    • /
    • 2020
  • Prosthodontic decision and management should be considered the patient's aesthetic need for anterior teeth in maxillary edentulism. This case report describes 10-year clinical outcome of a maxillary edentulous patient was rehabilitated by means of an implant-supported fixed dental prosthesis (ISFDP) for the anterior region and a distal-extension removable partial denture (RPD) for the posterior region. The ISFDP was designed to splint 4 endosseous implants as one unit and engaged by the RPD. The edentulous mandible was restored by means of an implant-supported overdenture. Over the course, no major adverse event occurred other than wear, discoloration, and breakage of resin veneers and artificial teeth.

Overdentures of the patient with Parkinson's disease: A case report (파킨슨 병을 가진 환자의 상악 마그네틱 피개의치 및 하악 임플란트 피개의치 수복 증례)

  • Min, Byung-Kwee;Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.352-358
    • /
    • 2015
  • The retention of complete dentures in patients with Parkinson's disease is often poor due to their constant dislodgement by involuntary movements of the tongue and lips. Furthermore, insertion of the overdenture is expected to be difficult due to their limited voluntary movements. This case is about the bimaxillary overdenture restoration where its retention and stability are improved, using magnetic attachment of remained roots of maxilla and two implant $Locator^{(R)}$ attachments of mandible in patients with Parkinson's disease. This report describes the fabrication of this functionally improved prosthesis.

Prosthetic restoration of a partially edentulous patient using double crowns: a clinical report (이중관을 이용한 부분 무치악 환자의 수복 증례)

  • Park, Minseo;Kim, Hyeong-Seob;Kwon, Kung-Rock;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • In removable dental prostheses, it is important to minimize impairment of residual tissue caused by wearing dentures. There are two factors that harm residual tissue. The first is functional load bearing of remaining teeth and alveolar ridges and the second is the effect of poor oral hygiene. Double crown retained removable dental prostheses provide rigid support, and it may reduce impairment caused by load bearing of alveolar ridges. Also, dental plaque and oral deposits, which are attached to outer crowns and dentures, can be easily managed extra-orally. In addition, it is beneficial to the health of the marginal gingiva because inner crowns have easy access for oral hygiene. In this case, double crown retained removable dental prostheses were used for the partially edentulous patient with severe residual alveolar bone resorption and poor oral hygiene, and the result was clinically satisfactory in terms of functional, esthetical, and oral hygiene aspects.

Surveyed restoration and RPD framework design utilizing electronic surveying (전자 서베잉을 이용한 서베이드 금관과 국소의치 프레임워크 디자인)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Seong-Kyun;Koak, Jai-Young;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.354-361
    • /
    • 2011
  • There are still many limitations on fabricating dentures using digital method while computerized production of fixed prostheses utilizing intraoral scanner and CAD/CAM technology has propagated rapidly. Recently the digital solution of fabricating removable partial denture by applying haptic input device, electronic surveying, and rapid prototyping was introduced. In this case presentation, five patients were treated with surveyed crown and removable partial dentures by this digital solution. Fit of dentures was excellent except for one case which showed morphological difference between the actual teeth and that of master cast by the erroneous impression process. There also was not any problem of stability and retention after adaptation in the clinical setting.

Implant-supported milled bar overdenture with two implant surgical guides (두 개의 수술용 가이드와 Milled-bar를 이용한 임플란트 피개 의치 수복 증례)

  • Pill-Sang Yun;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.55-62
    • /
    • 2023
  • For fully edentulous patients, implant-supported overdenture can be considered to enhance chewing efficiency and denture stability. Implant planning software can be used to fabricate a surgical guide for a more precise consideration of anatomic factors and prediction of the shape of definitive prosthesis. Though there are many possible attachments for implant overdenture, milled bar can be useful due to its splinting effect of implants and rigid support of overdenture. This report presents a case of implant-supported milled bar overdenture after guided implant surgery performed with two surgical guide that was fabricated before and after bone reduction.