• Title/Summary/Keyword: 의료폐기물

Search Result 65, Processing Time 0.029 seconds

Temperature Evaluation on Long-term Storage of Radioactive Waste Produced in the Process of Isotope Production (동위원소 생산공정에서 발생한 방사성 폐기물 장기저장소 온도평가)

  • Jeong, Namgyun;Jo, Daeseong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.471-475
    • /
    • 2016
  • In the present study, temperature evaluations on long-term storage of radioactive waste produced in the process of isotope production were performed using two different methods. Three-dimensional analysis was carried out assuming a volumetric heat source, while two-dimensional studies were performed assuming a point source. The maximum temperature difference between the predictions of the volumetric and point source models was approximately $5^{\circ}C$. For the conceptual design level, a point source model may be suitable to obtain the overall temperature characteristics of different loading locations. For more detailed analysis, the model with the volumetric source may be applicable to optimize the loading pattern in order to obtain minimum temperatures.

A Study on the Method of Cost Estimation for the Decommissioning Plan by the Analysis of Domestic Cyclotron Dismantling Practices (국내 사이클로트론 해체 사례 분석을 통한 해체 계획 비용 산정 방법 연구)

  • Woo, Rina;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.97-103
    • /
    • 2014
  • Decommission of medical cyclotron give rise to a lot of low-level radioactive waste and costs. Decommissioning cost should be reasonably calculated according to the decommissioning activities and installed components of facilities. In this paper, we investigated the experience on the cyclotron relocation from SNUH(Seoul National University Hospital) to SKKU(Sungkyunkwan University) and analyzed radioactive waste management costs by applying the disposal scenarios. Also considerations for decommissioning cost estimation are reviewed. The results could be utilized as a basic data for establishment on the methodology of decommissioning cost estimation and evaluation.

Infection Control practices in accordance characteristic of Dental institutions -Daegu and North Gyeongsang Province around- (치과의료기관의 특성에 따른 감염관리실태 -대구, 경북지역을 중심으로-)

  • Sung, Mi-Ae;Yoon, Sung-Uk
    • Journal of Digital Convergence
    • /
    • v.16 no.5
    • /
    • pp.299-307
    • /
    • 2018
  • This study survey research of infection control, wastewater management, and instrument disinfection according to characteristic at Daegu, Gyeongbuk Province In 2012 and 2017, the same 114 dental clinics to identify the infection management behavior and prevent infection of dental medical institutions. Scored mean 3.37 points on 8 items of infection control, 95.5% in "records of the patient's medical history", 1.8% in "presence of a wastewater facility." Scored 94.7% in "disinfection of metal trays", 17.5% in "storage from a spitting receptacle in the waste bin and commissioned management.", Scored higher in of infection control, wastewater management and instrument disinfection according to general characteristics and dental characteristics in 2017 than in 2012. Points were higher dental hygienist, University graduation, Type of duty was counseling and management, hospital or higher, Number of dentist(dental hygienist, chair, patient) was high. Therefore raise a need for infection control into consideration the dental characteristics and education and promotion regardless of the hospital size.

Clinical Practice of COVID-19 and Infection Control by Dental Hygiene Students in Jeju Province (제주지역 치위생과 학생의 COVID-19와 감염관리 임상실습 수행 실태)

  • Baek, Soo-Jeong;Woo, Jaeman;Kim, Sung-Joon
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.2
    • /
    • pp.370-378
    • /
    • 2022
  • The purpose of this study was to investigate the factors affecting infection control practice by dental hygienist students in Jeju during clinical training amidst the COVID-19 pandemic. Online survey was conducted on 112 students and the results were statistically analyzed with frequency analysis, Student's T-test, one-way ANOVA, and regression analysis using SPSS 20.0. In the 'awareness and practice of infection control by year in college' section, 2nd year students scored significantly higher in 'cleaning and surface disinfection,' 'medical waste disposal,' and 'COVID-19 preventive measure' compared to 3rd year students. In the 'type of training institution' section, hospital setting scored significantly higher in 'cleaning and surface disinfection,' 'instrument disinfection and sterilization,' 'personal and patient protection,' and 'COVID-19 preventive measure' compared to dental clinic setting. In the 'location of institution' section, Seoul metropolitan region scored higher in 'medical waste disposal' compared to Jeju region. According to regression analysis, year in college (2nd year), type of training institution (hospital setting), location of training institution (Seoul metropolitan region), and difficulty using protective gear (no difficulty) were associated with better COVID-19 preventive measure This first study in Jeju provides an insight on the awareness and practice of infection control measures by dental hygienist students in Jeju during clinical training. Further investigation for improvement of clinical training manual is warranted.

Design of a Tag Antenna with a Low Performance Distortion from an Attached Surface Material Using the Asymmetric Dual-Arm Dipole Structure (부착면 표면물질에 의한 성능 왜곡을 최소화한 이중 선로의 비대칭 다이폴 형태 태그 안테나 설계)

  • Kim, Do-Kyun;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.398-407
    • /
    • 2007
  • In this paper we proposed the tag antenna with a low performance distortion from an attached surface material using the asymmetric dual-arm dipole antenna(ADDA) structure. The tag is designed to exhibit low performance changes when the tag is attached on a target object(the medical litter receptacle, ${\varepsilon}_r=1.7,\;tan\;{\delta}=0.002$). Detail design parameters for the proposed antenna are optimized to maintain a good readable range in free-space as well as on a target object. The size of the optimized antenna is $100\;mm{\times}50\;mm$. The antenna shows the matching bandwidth($S_{11}$< -10 dB) of 3.7 % and the radiation efficiency of 80 % at the operating frequency. Finally we confirmed the readable range of the tag antenna by measurement and it shows about 5.3 m in free space and 5.5 m on the target object.

Analysis of Radioactive Characterization in the Medical Linear Accelerator Shielding Wall Using Monte Carlo Method (몬테칼로법을 이용한 의료용 선형가속기 차폐벽의 방사화 특성 분석)

  • Lee, Dong-Yeon;Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.758-765
    • /
    • 2016
  • This study analyzed for the radioactive shielding wall, which shields the medical linear accelerator. This allows to evaluate the level of waste with respect to the shield wall, which accounts for more than half of the cost of dismantling later linac facility. In addition, by analyzing the waste processing method according we discuss the way to obtain the benefits in terms of dismantling cost. Results of the simulate, the amount sufficient to screen the amount of neutron radiation occurring in the shielding wall linac was measured. And neutron activation analysis results were analyzed nuclides more than about 20. This analysis was in excess of that, $^{24}Na$, $^{45}Ca$, $^{59}Fe$ nucleus paper deregulation concentration. The value is reduced is greater the deeper the depth of the shielding wall concentration. Based on this, three specific areas (E, F, G) was estimated to be impossible to landfill or recycling. The rest area was estimated to be buried or recycled if possible more than a predetermined depth.

A Study of Nurses' Knowledge, Attitude and Practice Regarding Medical Waste (Busan and Kyongnam Province University Hospitals) (간호사의 의료폐기물에 대한 지식, 태도 및 실천에 관한 연구(부산, 경남지역 대학병원을 중심으로))

  • Yu, Su-Jeong;Ha, Won-Chun;Park, Young-Mi;Ha, Yoon-Ok;Bae, Kyung-Hee
    • The Korean Journal of Health Service Management
    • /
    • v.11 no.1
    • /
    • pp.79-89
    • /
    • 2017
  • Objectives : As a descriptive study, the present research investigated the knowledge, attitude, and practice regarding medical waste and factors influencing these variables, based on nurses working at university hospitals in Busan and Gyoengnam provinces. Methods : The 508 participants were selected from five university hospitals in Busan and Kyongnam provinces and consented to participate in the study between June 1 and July 15, 2016. The collected data were analyzed by using SPSS 23.0 based on descriptive statistics, t-test, ANOVA, Scheffe's test, Person correlation coefficients, and hierarchical analysis. Results : The average scores for knowledge, attitude, and practice regarding medical waste among the participants were 15.88 (1.71), 4.38 (0.45), and 4.24 (0.40) respectively. When the scores for the knowledge and attitude related to medical waste were higher, the score for practice (r=.500, p<.001) increased, and the most influential factor on practice regarding medical waste was attitude toward medical waste (${\beta}=.45$, p<.001). Conclusions : Thus, to reinforce a positive attitude toward medical waste management, continuous education and a systematic approach to minimize health and environmental hazards are needed.

A Priority and Impact Factor Analysis of Construction Management Tasks for Decreasing Change Orders and Defect Repairs in Cancer Treatment Center Projects (암센터 의료시설의 설계변경과 하자보수의 감소를 위한 중점 관리공사 분석)

  • Lee, Chijoo;Lee, Ghang;Sim, Jaekyang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.5
    • /
    • pp.55-64
    • /
    • 2013
  • The complexity of constructing medical institutions is higher than that of general buildings, and many change orders in the design and defect repairs in the construction phase are required due to strict government regulations. The priority control of constructions and impact factors of medical institutions were analyzed in this study, and difficulties in the control in the design and construction phase were identified. First, the priority management factors that were identified were as follows: architecture, facilities, and electricity. Second, 1) priority management in constructions and factors resulting in change orders and 2) priority management in constructions involving defect repair were analyzed. Third, the importance recognized by the construction managers were analyzed. The priority management in constructions and factors that were recognized by the construction manager were deducted as having low importance, although there were many change orders and defects. The work of finishing, wall building, joining, office automation and communication function, and lighting were analyzed in the design phase, and waste, the office automation and communication function, ceilings, contamination control, and plumbing were analyzed in the construction phase. The results showed that there will be a decrease in change orders and defects if the concentration of the manager was elevated and priorities were managed.

Current Status on Gold Smelting Technology (금제련(金製鍊) 기술(技術)의 현황(現況))

  • Kim, Byung-Su;Kim, Chi-Kwon;Sohn, Jeong-Soo
    • Resources Recycling
    • /
    • v.16 no.3 s.77
    • /
    • pp.3-11
    • /
    • 2007
  • Presently, most of gold is smelted from gold concentrates and anode slimes. Anode slimes are by-products of nonferrous smelters such as lead and copper. In addition, gold is recovered from waste dental and medical materials, waste gold coating solution, and waste printed circuit boards (waste PCBs). The smelting method of gold from gold concentrates and various wastes containing high concentration of gold is largely divided into chlorination, cyanidation, and amalgamation methods. For the anode slimes, electrolysis method is usually used, which largely consists of roasting, high temperature melting and electrolysis processes. Also, various wastes containing low concentration of gold are mainly treated by pyrometallursical processes. In the paper, current status on gold smelting technology is reviewed, and a novel process for gold smelting which is researched in the recent is briefly introduced.

Treatment Study on the Combustion Gas of Medical Waste (의료폐기물 소각가스 처리에 관한 연구)

  • Lee, Sung-Jin;Seo, Man-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • Currently, medical waste stoker incinerator is widely used in the emission control technology of health-care risk waste and miscellaneous contaminated waste. In the past, wet type control technology was used to remove the major harmful gaseous contaminants of medical waste such as HCl, $NO_x,\;SO_2$, CO, DUST, Dioxin. However, the treatment cost for wastewater was high and it has a disadvantage for frozen system during winter season. Therefore, in order to obtain effective treatment, the dry type control technology was developed and widely used to remove the gaseous contaminants. In this study, pre-coated bag filter using hydrated lime, ($Ca(OH)_2$), was applied to the dry type control system and the optimum dose of hydrated lime was investigated. The treatment results showed that the dust collection rate was approximately 26.7%. Moreover, the HCl removal rate using pre-coated bag filter ($50mg/sm^3\;Ca(OH)_2$) was 13.52%, which was significantly higher than 3.26% obtained from conventional bag filter.