• Title/Summary/Keyword: 의료영상 장비

Search Result 196, Processing Time 0.029 seconds

Utilization value of medical Big Data created in operation of medical information system (의료정보시스템 운영에서 생성되는 의료 빅데이터의 활용가치)

  • Choi, Joon-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.12
    • /
    • pp.1403-1410
    • /
    • 2015
  • The purpose of this study is to provide ways to utilize and create valuable medical information utilizing Medical Big Data created by field in hospital information system. The results of this study first creates new medical information of Medical Information system through medical big data analysis and integration of created data of PACS linked with many kinds of testing equipment and medical image equipment along with medical treatment information. Medical information created in this way produces various health information for treatment and prevention of disease and infectious disease. Second, it creates profit statistics information in various ways by analyzing medical big data accumulated through integration of billings and receipt, admission breakdown of patients. Profit statistics information created in this way produces various administration information to be utilized in profit anaysis and operation of medical institution. Likewise, data integration of personal health history, medical information of public institutions, medical information created in hospital information system produces valuable medical health information utilizing medical data.

A Study on Design and Implementation of The Image Diagnostic Solution based on Real Time Embedded Linux (실시간 임베디드 리눅스 기반의 영상진단 솔루션 설계 및 구현에 관한 연구)

  • 이상훈;이기화;문승진
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.463-465
    • /
    • 2004
  • 베디드 시스템의 발전으로 인하여 고성능화, 소형화, 편의성 등이 강조되어 지는 시점에서 의료장비 또한 임베디드 시스템 기술 도입이 빠르게 진행되어 지고 있다. 본 논문에서는 초음파 영상진단 단말기 (Magic-Probe)를 구현하기 위해 SA-1100 마이크로 프로세스 레퍼런스 보드에 리눅스 커널을 포팅하고 포팅된 플랫폼을 기반으로 초음파 영상진단을 처리하기 위한 응용프로그램의 설계 및 구현에 관하여 논하도록 하겠다.

  • PDF

The diffusion and policy options of the diagnostic imaging technologies in Korea (의사결정나무 분석을 사용한 고가의료장비의 다빈도 사용 특성 분석)

  • Choi, Yoon Jung;Kwak, Minjung;Yoon, Min
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.1
    • /
    • pp.179-185
    • /
    • 2015
  • The cost of advanced medical technologies is commonly considered to be a major factor in the overall escalation of expenditures on health. The use of computed tomography (CT) scanning has increased dramatically over the past decade. CT has been rapidly adopted, despite their high cost. The aim of this study is to analysis the increasing factor of the frequency of the CT, using the decision tree model. Finally, we propose the effective policy option of diagnostic imaging technology in Korea.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

The Research of Design Development for Strengthening Competitiveness of Domestic Medical Instrument Industry -Focused on C-Arm Surgical X-Ray Design- (국내 의료기기산업 경쟁력 강화를 위한 디자인개발에 관한 연구 -이동형 영상진단기기 디자인을 중심으로-)

  • Han, Il-Woo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.51-60
    • /
    • 2004
  • The medical instrument industry which is one of the high value added industry has been neglected on the various system and political support because it has been recognized as an unknown field to the public although it is the very easy-approaching field for the export market that minimize a technological gap between advanced country and Korea. Especially, the product design that is very important element for the efficient medical treatment and the psychological stabilization of patient is a typical field of lack of investment and support by the unconcern and lack of understanding of design. Therefore this research suggests the current problem of design with the general inquiry of internal and external market situation and domestic medical instrument industry and also it has the conclusion of an alternative proposal for the solution with the design development processing of a moving type-image diagnostic equipment. We will emboss the importance of design competitiveness, suggest the model and basic data to the medical instrument company that starts later, and be a role of inspiration for the lasting investible desire with this research.

  • PDF

PDA Transmission of Medical Images by CDMA (CDMA에 의한 의료영상의 PDA전송)

  • Lee, Myong-Ho;Lim, Jae-Dong;Ahn, Bung-Ju;Lee, Hwun-Jae;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.13-22
    • /
    • 2007
  • The purpose of this study was to survey a development of the wireless transmission system of medical images for ubiquitous medicine. There have been many changes in medical equipments and medical record medical treatment and medical record within hospital and PACS(Picture Archiving Communication System) which is picture management system for patients can be typical cases. It is difficult to use these automated medical systems unless they are within hospital and in case of rapid image reading in the emergency cases or in absence of doctor, it is difficult to perform it immediately. The present study implemented an image transmission system using CDMA connection so that images in the server can be viewed at any time and in any place. Remote wireless diagnosis based on medical images using PDA is applicable to medical areas that require mobility, and the use of PDA can be an ideal alternative for point of care. The use of PDA enables prompt and accurate access to digital medical images, which in turn reduces medical accidents and improves the quality of medical services through high productivity and efficiency of medical practitioners' works. It also enables quick response to patients' demands and high-quality medical services and, consequently, patients' high satisfaction.

  • PDF

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.

Pollution Research about Radiology radiographic laboratory (방사선 영상학 실습실 오염실태 조사 (D대학교 DR장비와 방사선 발생장치, Cassette 오염실태 조사))

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.69-76
    • /
    • 2013
  • We checked the existence of bacteria at DR equipment, radiation generator and cassette in 'D university' to propose optimized management method for bacteria and disinfection at DR equipment, radiation generator and cassette at used in radiographic laboratory of the department of radiology. The infected region is treated by alcohol and cresol and compared before spraying and after spraying for 1, 3, 5 and 10 minutes. As time goes on, amount of bacteria colony decreases significantly. The Cresol is useful to disinfect the diminutive devices. However alcohol disinfection, at least 5 minutes later, and hand washing before practical training and shooting image is recommended due to the big and fixed radiography equipment which cause the soakage.

  • PDF

Design and Analysis of Hospital Management Agent in PDA Environment (PDA 환경에서의 병원관리 Agent의 분석 및 설계)

  • Lee, Hyoung-Sunk;Jung, Sung-Hoon;Kim, Chang-Su;Yim, Jae-Hong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05b
    • /
    • pp.787-790
    • /
    • 2003
  • 통신기술과 의료장비의 발달은 환자에 대한 의료혜택의 기회를 확대하고, 최상의 의료서비스를 제공하려는 병원들에 있어서 전산 시스템은 빼놓을 수 없는 병원내 주요 기반시설로서 등장하게 되었다. 멀티미디어 기술과 정보통신의 발달은 의료분야의 정보화 및 자동화 기술 발전에 커다란 영향을 주어 의료 영상 및 각종 의료정보를 고속의 네트워킹 올 통해 전송할 수 있는 PACS(Picture Archiving and Communications System)의 개발을 가능하게 하였다. 본 논문에서는 무선네트워크의 발달과 PDA(Personal Digital Assistants)의 보편화에 따라 PDA를 이용하여 HIS(Hospital Information System)/RIS(Radiology Information System)/PACS의 자료를 검색 및 갱신할 수 있도록 설계하고, 현재 병원의 데이터베이스와 PDA의 연동이 가능하도록 병원관리 에이전트를 분석 및 설계하였다.

  • PDF