A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.

A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging (핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰)

  • Ji-Hyeon Kim;Jooyoung Lee;Hoon-Hee Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

Improvement Way for Mobile X-ray Examinations by Rule Revision about Safety Management of Diagnosis Radiation Occurrence System (진단용방사선발생장치의 안전관리에 관한 규칙 개정에 따른 이동형 방사선검사의 개선방안)

  • Choi, Jun-Gu;Kim, Gyeong-Su;Kim, Byeong-Gi;Ahn, Nam-Jun;Kim, Hyeong-Sun;Kim, Sang-Geon;Lim, Si-Eun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A safety management rule of the diagnosis radiation system which opened a court 2006 February 10th was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this study is to minimize injury by radiation that can happen to patients and people around a sick ward when managing mobile X-ray system. This study analyzed sickroom environment of mobile X-ray examination and the statistical data of the Konkuk medical Information System(KIS) and the Picture Archiving Communication System(PACS). This study also investigated patient conditions, infection, relation information and related data, when the sickroom mobile X-ray examination is used. Through data analysis, many problems were expected such as restriction of space side, manpower and expense of business side, satisfaction degree decline of patient and protector of operation side. Therefore, we tried to restrict examination of multi bed sickroom, and to use treatment room in each ward to solve problem mentioned. As a result, the whole sickroom mobile X-ray examination rate decreased to near 50%, and mobile X-ray examination rate for inpatients decreased to more than 85%. This study shows that several attempts we did should be helpful for manpower, patients satisfaction and expenses. Also, they should protect patients in sickroom from unnecessary radiation exposure and could minimize inconvenience of patients and their family members from x-ray examination.

  • PDF

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography (고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Ho-Beom;Na, Sa-Ra;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5682-5688
    • /
    • 2013
  • The purpose of this study is to maximize diagnositc usefulness with increasing signal to noise ratio(SNR) and contrast to noise ratio(CNR) by using a 1mmol/mL gadolinium contrast agent. From January 2012 to June 2013 fourty-seven patients were underwent the MRI scanning to investigate the contrast difference in gadolinium content. Twenty of the patients were injencted the commercial contrast agent containing 0.5mmol/mL gadolinium and the rest of them were injected the new contrast agent containing 1mmol/mL gadolinium called gadobutrol. We measured and evaluated each SNR and CNR of the hip joint space, iliopsoas muscle and femoral head. As a result, using the 1mmol/mL gadolinium contrast agent had the higher SNR results than using the 0.5mmol/mL agent(27% in the hip joint, 30.01% in the femoral head). Also CNR using the 1mmol/mL gadolinium agent was proved to be higher than that of using 0.5mmol/mL agent(28.31% in the ilopsoas muscle and 26.74% in the femoral head). Therefore, the contrast agent containing more gadolinium like 1mmol/mL used in this study is more effective to shorten T1 relaxation time, so it increases the signal intensity and CNR and furthermore maximizes diagnostic value. This study reports the usefulness of the 1mmol/mL contrast agent in the contrast-enhanced magnetic resonance hip arthrography for the first. Therefore, it can be considered to have an meaningful academic value as showing the method for increasing the diagnostic usefulness by using the 1mmol/mL contrast agent.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

A Survey about the Knowledge, Attitudes and Behavior for Radiation Safety Management of Operating Room Nurse and Dental Hygienists (수술실 간호사와 치과위생사의 방사선 안전관리 지식과 태도 및 행위에 대한 비교조사)

  • Yoon, Jung-Ae;Yoon, Young-Suk
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.230-239
    • /
    • 2014
  • This study is to promote awareness to be exposed to radiation with identifying knowledge, attitudes and behavior for radiation safety management of the operating room nurse and dental hygienist. And the following results were obtained through questionnaire survey to deduct the education to prevent potential risks in advance and implication to be useful on education program. First, based on the level of knowledge for radiation safety management, 10.57 for dental hygienists, 9.55 for the nurse out of 15 points (p<0.001); based on the level of attitudes for radiation safety management, 4.64 for dental hygienists, 4.67 for the nurse out of 5 points (p<0.001); and based on the level of behavior for radiation safety management, 3.27 for dental hygienists, 2.93 for the nurse out of 5 points (p<0.001). Second, the result for checking the relation with knowledge, attitudes and behavior for radiation safety management, the knowledge of radiation safety management has correlation with attitudes and behavior for radiation safety management statistically (p<0.001).

A Study and Design of Beam Scanning Array Antenna using IR-UWB (IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구)

  • Kim, Keun-Yong;Kang, Eun-Kyun;Kim, Jin-Woo;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.194-201
    • /
    • 2014
  • This paper is able to be solved by improving degradation in multi-path environment by adjust beam pattern angle through modifying pulse phase of each antennas by using TRM (Transmitter Receiver Module). Beam Scanning Array Antenna, which is transmitter/receiver that improves degradation in multi-path environment without any signal distortion, is designed and manufactured. Beam Scanning Array Antenna should be able to send/receive signal at the antenna's longitudinal part without distortion and should not influences other systems. Also, it should include target detecting ability by beam steering.Dispersion characteristic of Beam Scanning Antenna, which is designed, is analysed by using fidelity, and steering and radar resolution performance is verified by using $1cm{\times}1cm$ sized target. To manufacture Beam Scanning Array Antenna, control board and GUI, which is able to control Vivaldi Antenna for IR-UWB, Tri-Band Wilkinson power divider, and TRM (Transmitter Receiver Module), is designed. Throughout this research, developed Beam Scanning UWB Array Antenna system is adoptable for radar application field. and time domain analysis techniques by using network analyser made the antenna characteristics analysis for setting up antenna more accurate. In addition, it makes beam width checking without difficulties.

Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development (X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발)

  • Lee, Kwang-In;Jang, Jin-Soo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.331-339
    • /
    • 2016
  • Chronic diseases are increasing nowadays as daily habits changed due to economic growth. Among chronic diseases, heart cerebrovascular disease is one of the major causes of death in South Korea that accounts for approximately 20% of mortality. Tests to measure anomaly of the heart is ECG tests, which measures and analyzes the electrical heart activity. Any mistakes in lead attachment location critically affects ECG testings, and statistical facts showed that only 2.8% of the nurses properly located leads to patients. As a solution, this paper proposes a system based on a projection-based augmented reality technology to generate X-ray images to the patient's chest to point out exact attachment locations of ECG leads. Evaluation comparison results showed a 2.6 cm difference between the conventional system and the proposed system. ECG test results also showed significant signal differences between the systems in leads V1, V2, and V3. The ECG measured accurately by the proposed system would help greatly in patient management and clinical decisions of clinicians.

Development of Linking & Management System for High-Resolution Raw Geo-spatial Data based on the Point Cloud DB (Point Cloud 기반의 고해상도 원시데이터 연계 및 관리시스템 개발)

  • KIM, Jae-Hak;LEE, Dong-Ha
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.4
    • /
    • pp.132-144
    • /
    • 2018
  • 3D Geo-spatial information models have been widely used in the field of Civil Engineering, Medical, Computer Graphics, Urban Management and many other. Especially, in surveying and geo-spatial field, the demand for high quality 3D geospatial information and indoor spatial information is so highly increasing. However, it is so difficult to provide a low-cost and high efficiency service to the field which demand the highest quality of 3D model, because pre-constructed spatial data are composed of different formats and storage structures according to the application purpose of each institutes. In fact, the techniques to construct a high applicable 3D geo-spatial model is very expensive to collect and analyze geo-spatial data, but most demanders of 3D geo-spatial model never want to pay the high-cost to that. This study, therefore, suggest the effective way to construct 3D geo-spatial model with low-cost of construction. In general, the effective way to reduce the cost of constructing 3D geo-spatial model as presented in previous studies is to combine the raw data obtained from point cloud observatory and UAV imagery, however this method has some limitation of usage from difficulties to approve the use of raw data because of those have been managed separately by various institutes. To solve this problem, we developed the linking & management system for unifying a high-Resolution raw geo-spatial data based on the point cloud DB and apply this system to extract the basic database from 3D geo-spatial mode for the road database registration. As a result of this study, it can be provided six contents of main entries for road registration by applying the developed system based on the point cloud DB.