• Title/Summary/Keyword: 의료기관 종사자

Search Result 178, Processing Time 0.027 seconds

A Survey on Awareness and Availability on Items of 2018 Assistive Devices Distribution Program for the Disabled in the Occupational Therapists (2018년도 장애인 보조기기 교부사업 품목에 대한 작업치료사의 인식도와 활용도 조사)

  • Kim, Jeong-Eun;Park, Je-Min;Bae, Su-Yeong;Jung, Nam-hae
    • Korean Journal of Occupational Therapy
    • /
    • v.26 no.4
    • /
    • pp.85-95
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the awareness and availability on items of 2018 assistive devices distribution program for the disabled in the occupational therapists. Methods : A total of 132 occupational therapists participated in the survey from May 1 to May 31. Results : 96.2% of the occupational therapists responded that assistive device is helpful in lives of the disabled people. Especially, they responded that assistive device is the most helpful in 'movement and mobility'. Awareness on an angle spoon/fork with built-up handle and universal cuff was the highest, while a visual signaling indicator was the lowest. Availability on an air cushion was the highest, while a visual signaling indicator and a voice guidance system were the lowest. 67.4% responded that 'sometimes' they use the assistive device and 77.3% responded they will utilize the assistive device. To improve awareness and availability, 43.2% needed financial support, 32.6% needed to add insurance bill and 22.7% needed related education. Conclusion : In the future, this result will be available as a basic data for the education about assistive device for the occupational therapists.

Comparison of Ventilation Effects by Mask Type for Proper Health Care of Respiratory Emergency Patients (호흡응급환자의 적절한 헬스케어를 위한 마스크 유형별 환기효과 비교)

  • Kim, Tae-Hyun;Park, Si-Eun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.477-485
    • /
    • 2020
  • This study is a random allocation similar experimental study to compare and analyze the difference in BVM (Bag-Valve-Mask) ventilation volume according to the characteristics of the rescuer's hand and the type of mask using a standardized mannequin. To this end, the Basic Life Resuscitation Education Center of D University in gwangju. Recruiting 39 students who have completed the basic resuscitation course for emergency medical personnel and the Korean-style specialized cardiac rescue course, In addition to measuring the physical characteristics of the hand, the average amount of ventilation per minute using a bag-mask was measured and analyzed. As a result, the type of mask that was not most affected by the characteristics of the hand and provided adequate Minute Ventilation was the soft type (tube, silicone) mask. On the other hard (tube, silicone) masks were found to be unsuitable for general use as they were greatly affected by the characteristics of workers' hands. COVID-19 is currently increasing the risk of transmission to paramedics and patients. Considering this situation, the universal use of a semi-permanent hard-type mask, which is disadvantageous not only for preventing infection but also for proper ventilation, should be avoided. In addition to the ease of use, it should be actively utilized in the field by supplying a soft type mask that can provide stable ventilation even with 'predominance recognition' and proper ventilation.

Laboratory Diagnosis of Coronavirus Disease 19 (COVID-19) in Korea: Current Status, Limitation, and Challenges (국내 중증 급성 호흡기 증후군 코로나 바이러스의 검사실 내 진단: 현재, 한계점 그리고 직면한 과제)

  • Song, Gi Seon;Lee, You-Rim;Kim, Sungmin;Kim, Wontae;Choi, Jungwon;Yoo, Dahyeon;Yoo, Jungyoung;Jang, Kyung-Tae;Lee, Jaewang;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.284-295
    • /
    • 2020
  • In December 2019, the first coronavirus disease- 2019 (COVID-19) patient was reported in Wuhan, Hubei Province, China. Since then, the number of patients who suffered severe acute respiratory syndrome caused by the novel Coronavirus (SARS-CoV-2 or 2019-nCoV) has increased dramatically in Korea. This new variant virus induces pulmonary diseases, including cough, sore throat, rhinorrhea, dyspnea, and pneumonia. Because SARS-CoV-2 is an RNA virus, real-time reverse-transcriptase PCR has been used widely to diagnose COVID-19. As the Korea Centers for Disease Prevention and Control (KCDC) and Ministry of Food & Drug Safety (MFDS) approved emergency use authorization, clinical specimens collected from COVID-19 patients and even healthy people have been clinically diagnosed by laboratory medicine. Based on a literature search, this paper reviews the epidemiology, symptoms, molecular diagnostics approved by KCDC, a current diagnosis of COVID-19 in the laboratories, the difference between molecular and serological diagnosis, and guidelines for clinical specimens. In addition, the Korean guidelines of biosafety for clinical laboratory scientists are evaluated to prevent healthcare-associated infection. The author's experience and lessons as clinical laboratory scientists will provide valuable insights to protect the domestic and international health community in this COVID-19 pandemic around the world.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

A cognitive survey on the Diversification of class year from Junior Colleges by Changing Educational Environment-Focused on Health Sciences Departments (교육환경 변화에 따른 전문대학 수업 연한 다양화에 대한 인식조사 - 보건계열학과 중심으로)

  • Park, Cheolin;Park, Su-Jin;Kwon, Soon-Mu;Kim, Won-Gi;Chang, Ki-whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.186-196
    • /
    • 2018
  • Junior colleges are higher education institutions that have played a major role in the economic development of Korea by providing the necessary human resources for its industrial development. Recently, however, they have experienced difficulties due to the reduction in the number of students. Therefore, it is time for junior colleges as a representative higher vocational education institution to change their role in this rapidly changing environment, and adopt a survival strategy through mutual cooperation and competition. The purpose of this study was to analyze the current state of the national health universities, to investigate the policy changes adopted by colleges and universities, and to utilize the results as data. This study analyzed the current status of health science colleges nationwide and investigated the policy changes as well as the directions presented to the colleges, in order to use the results as the basic data to promote the diversification of the class periods and degree programs. This study surveyed 636 professors from health sciences departments and industry workers from May 1 to May 30, 2017. 70.7% of the respondents supported the transition of the existing three-year systems of the health science departments to four-year systems. The reason for this is that it is possible to strengthen the field practice and personality education of the students by having a sufficient number of class periods, and to provide them with an equal educational background. The most anticipated effect of the transition to a four-year system is to improve the social status of medical personnel and to improve the educational environment of the colleges/universities. Moreover, the universities, associations of medical personnel and Ministry of Education are expected to play a leading role in the transition to the four-year system. Based on the results of this study, it was concluded that a more systematic and advanced vocational education system for the training of professional healthcare workers is needed in the upcoming fourth Industrial Revolution era. Also, this transition is expected to actively foster the education of advanced health care workers thanks to the diversification of the degree programs through the adjustment of the class periods which can be completed by general university (4-year) graduates.

A Prediction Model for the Radiation Safety Management Behavior of Medical Cyclotrons (의료용 Cyclotron의 방사선안전관리 행위 예측모형)

  • Jung, Ji-Hye;Han, Eun-Ok;Kim, Ssang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.77-86
    • /
    • 2008
  • This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: Step 1 is a production preparation step, Step 2 is an RI production step, Step 3 is a synthesis step, Step 4 is a distribution step, Step 5 is a quality control step, Step 6 is a carriage container packing step, and Step 7 is a transportation step. it was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipments' were the most difficult as 9 subjects (37.5%), and In the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was $3.46{\pm}0.47$ out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in radiation safety managements, general characteristics, organization characteristics, and selfefficacy didn't show a significant path statistically in which the prosperity and well-being programs in job characteristics affected the behavior in radiation safety managements. Therefore, it is necessary to establish a strategy that improves the level of prosperity and well-being levels in job characteristics in order to increase the behavior in radiation safety managements. Thus, this study provides basic materials for the radiation safety management of Cyclotron through the full-scale investigation that is first applied in Korea.