• Title/Summary/Keyword: 응축 증발법

Search Result 19, Processing Time 0.028 seconds

Characteristics of Unipolar Charging of the Submicron Particles by the Condensation-Evaporation Method (응축 증발법을 통한 서브마이크론 입자의 단극하전 특성)

  • Choi, Young-Joo;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.186-192
    • /
    • 2006
  • We applied a new charging system using the condensation and evaporation method to charge the submicron particles with a uniform charging performance. The monodispersed NaCl submicron particles were condensed by n-butanol vapor and grew up to micron droplets with a same size, regardless of their initial size. Those condensed droplets were charged in an indirect corona charger. The indirect corona charger consisted of the ion generation zone and the particle charging zone. In the ion generation zone, Ions were generated by corona discharge and some of them moved into the particle charging zone by a carrier gas and mixed with the condensed droplet. And finally, the charged and condensed droplets dried through an evaporator to shrink to their original size. The average charge and penetration rate of the particles before and after evaporation were measured by CPC and aerosol electrometer and compared with those of a conventional corona charger. The results showed that the average charge was $5\~7$ charges and the penetration rate was over $90\%$, regardless of the initial particle size.

3D Numerical Study of Horizontal Falling Film Evaporator in Multi Effect Distillation (MED) Plant (MED 담수기내 수평관 강하막식 증발기의 3D 수치해석적 연구)

  • Kim, Soo Jae;Je, Junho;Kim, Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.513-522
    • /
    • 2013
  • In the present work, a numerical study of a horizontal falling film evaporator in a multi-effect distillation (MED) plant is performed. Tube bundles in the evaporator are described as porous media, and a volume-averaged method is applied. To calculate the fluid flow and phase change in the evaporator due to heat transfer in the system, FLUENT and user-defined functions (UDF) are used. To observe the performance of the evaporator under different operational conditions, tests are conducted for a steam mass flux ranging from 0.5 to 2.5 $kg/m^2s$ in the horizontal tube, for mass fraction of the noncondensable gas in the tube inlet ranging from 0% to 1%, and for film Reynolds numbers ranging from 100 to 1,000 for the falling film. The evaporation rate increases with the steam mass flux and Reynolds number. In contrast, the evaporation rate decreases by 0.87% with a 1% increase in the mass fraction of the noncondensable gas in the tube.

다중 효용관 기계식 증기 재압축 증발기설계

  • 박종기;김권일;김태환;김종휘;유윤종;조성철;성재석
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.115-115
    • /
    • 1995
  • 다중 효용관식 증발기는 보통의 증발기에서 응축하여 제거하는 증기를 다음 효용관의 가열원으로 재사용하는 것으로 그 자체로도 에너지 절감효과가 있는 것으로 알려져 있다[1,2,4]. 기계식증기 재압축 증발기는 보통 증발기에서 응축시켜 제거하는 발생 증기를 압축하여 고온의 증기로 만든 다음 가열원으로 재이용하는 장치로 이에 대한 효용은 문헌에 잘 나타나있다[3,4]. 여기서는 다중효용관과 증기 재압축기를 조합한 증발기 중에서 Forward feed 방식의 다중효응관에 증기 재압축기를 부착한 경우에 대하여 타당한 물질수지, 열수지, 전열 식, 상평형식을 소개하였다. 또한 압축기의 용량을 결정하기 위한 단열압축공정의 지배방정 식을 소개하였다. 원료의 조건, 효용관의 수 및 총전열온도차가 주어지면 상기의 지배방정식의 해를 구할 수 있는데. 본연구에서는 Gauss-Seidel의 연속치환법을 이용하였다. 이와 같이 지배방적식의 해를 구하면 효용관의 면적, 압축펌프의 용량, 각효용관 입출구의 조건 등이 계산된다. 다중효용관 기계식 증기 재압축 증발장치의 최적화를 위하여는 효용관의 전열면적당 가격과 압축펌프의 용량당 가격 그리고 펌프를 운전하는데 필요한 전력의 요금 등의 자료가 요구된다. 총전열온도차에 따른 운전비와 시설비의 합이 최소가 되는 점이 최적 총전열온도차가 되는데 이 점을 구할 때에는 수치적으로 안정한 이분법을 이용하였다. Borland C++를 이용하여 프로그램하였으며 윈도우즈 환경에서 수행되게 하였다. 사용자 쉽게 이용할 수 있게 하기 위하여 각종 필요한 데이터를 입력할 수 있는 Edit box가 화면에 나타나게 하였다. 또한 입력된 데이터를 저장하거나 불려올 수 있는 메뉴, 입력된 데이타를 이용하여 효용관의 면적과 압축기의 용량을 계산하거나 효용관의 수가 주어졌을 때 총전열온도차를 최적화하는 것을 선택할 수 있는 메뉴 그리고 계산 결과를 파일로 혹은 프린트로 출력할 것을 선택할 수 있는 메뉴가 있다. 사용자는 해당되는 데이타를 입력한후 마우스로 원하는 작업의 메뉴를 선택하면 된다.

  • PDF

Ethanol dehydration pilot test with pervaporation technology (투과증발법을 이용한 에탄올 탈수 파일럿 시험)

  • 이규현;유제강;장재화;안승호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.10a
    • /
    • pp.42-45
    • /
    • 1994
  • 정밀화학, 제약산업 등에 필요한 에탄올, IPA 등과 같은 유기용매를 고순도로 농축하는 공정은 유기용매와 물과의 혼합물이 일정 농도에서 공비점을 형성하여 일반 증류로는 분리하기 힘들어 Benzene, Cycloheaxane 드의 Entrainer를 첨가하여 상대휘발도를 변화시켜 분리하는 공비증류가 이용되고 있다. 그러나 공비증류는 에너지 사용량이 많고 유독한 물질을 사용하므로 투과증발법과 같은 저에너지 소비형, 환경 친화적인 공정에 대한 관심이 높아지고 있다. 투과증발법에 의한 유기용매 농축공정은 물과의 친화성이 높은 비다공성 막을 이용하여 선택적으로 물을 투과하여 유기용매를 탈수하는 방법으로 투과를 위한 Driving force는 Feed side와 Permeate side사이의 Chemical potential gradient로 이는 물에 대한 Partial vapor pressure differnece로 다음과 같이 표시된다. $\Delta \mu_{F/P.W} = RT ln\frac{y_WP_P}{x_W\gamma_WP_{o.W}}$ 따라서 투과속도를 높이기 위해서 Permeate side를 진공상태로 하여 투과하는 물질을 기화시키고 이를 다시 응축하여 Permeate side의 압력을 낮게 유지시켜야 한다.

  • PDF

Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method (다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석)

  • ;;Yun, In-Chul;Yoo, Je-In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

Dehumidification and Evaporative Cooling Efficiency by Water Pipes in Greenhouse (냉수파이프에 의한 온실의 제습 및 증발냉각효율)

  • 김문기;남상운;윤남규
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.237-245
    • /
    • 1998
  • Greenhouse crop production under critical summer climate In Korea has considerable difficulties because of high temperature and relative humidity. In this study, some water pipes were tested as a means of the dehumidification and increment of evaporative cooling efficiency. As a result of heat transfer characteristic analysis, overall heat transfer coefficient of copper pipe was larger than steel pipe, and estimated values were smaller than measured values. The condensed quantities of vapor were not significantly different between copper pipe and steel pipe, however dehumidifying effect by the water pipes was significantly large. It was estimated based on the results that the evaporative cooling system by the water pipe will be able to increase the evaporative cooling efficiency of about 48%, and decrease the temperature of about 1.3$^{\circ}C$.

  • PDF

Evaporator Superheat Control of a Multi-type Air-Conditioning/Refrigeration System (멸티형 공조/냉동시스템의 증발기 과열도 제어)

  • 김태섭;홍금식;손현철
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.253-265
    • /
    • 2001
  • This paper investigates a PI control problem for the evaporator superheat, i.e., temperature difference between the two-phase region and the exit region of an evaporator, for multi-type air-conditioning/refrigeration system. Mathematical model describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, two transfer function from the current input applied to an electronic expansion valve to the wall-temperatures of an evaporator tube at two-phase region and superheated region, respectively, are derived. The stability of the closed loop system with the PI controller designed it analyzed by using Nyquist stability criterion. Simulation results are provided.

  • PDF

Magnetic Properties and Application of Caltalysts in Biginelli Reaction for the Ni and Ni@C Synthesized by Levitational Gas Condensation (LGC) (부양증발응축법으로 제조된 Ni과 Ni@C의 자성특성 및 Biginelli 합성 촉매 적용연구)

  • Uhm, Young Rang
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.3
    • /
    • pp.87-91
    • /
    • 2017
  • Carbon-encapsulated Ni and metal Ni nanoparticles were synthesized by levitational gas condensation (LGC). Methane ($CH_4$) gas was used to coat the surface of the Ni nanoparticles. The Ni particles had a core diameter of 10 nm, and were covered by 2~3 nm thin carbon layers with multi-shells structure.The low magnetization comparing with the Ni nanoparticles without carbon-shell results in the coexistence of nonmagnetic carbon and a large surface spin percentage with disordered magnetization orientation for the nanoparticles. Biginelli reactions in the presence of L-proline and Ni and carbon encapsulated Ni nanoparticles were carried out to change the ratio between stereoisomers. The obtained S-enantiomers for 3,4-dihydropyrimidine (DHPM) using catalysts of Ni, and Ni@C was an excess of about ${\Delta}{\sim}7.4%$ and ${\Delta}{\sim}19.6%$, respectively. The nanopowders were fully recovered using magnet to reuse as a catalyst. The Ni@C was shown at same yield to formation of 3,4-DHPM, though it was recycled for catalyst in the reaction.

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.