• 제목/요약/키워드: 응축 열전달 계수

검색결과 102건 처리시간 0.026초

세관내 R-22와 R-134a의 응축 전열 특성에 관한 연구 (Condensing Heat Transfer Characteristics of R-22 and R-134a in Small Diameter Tubes)

  • 홍진우;노건상;정재천;오후규
    • 대한기계학회논문집B
    • /
    • 제25권1호
    • /
    • pp.54-61
    • /
    • 2001
  • Condensing heat transfer coefficients of R-22 and R-134a were measured in smooth, horizontal copper tubes with inner diameters of 1.77mm, 3.36mm, and 5.35mm, respectively. The experiments were conducted in the closed loop, which was driven by a magnetic gear pump. Data are presented for the following range of variables : mass velocity from 200 to 500kg/$m^2$.s and quality from 0 to 1.0. The heat transfer coefficients in the small diameter tubes (ID < 7mm) were observed to be strongly affected by various diameters and the heat transfer characteristics in the small diameter tubes differed from those in the large diameter tubes. Heat transfer coefficients in the small diameter tubes are higher than those in the large diameter tubes at the same experimental condition. It was found that some well-known previous correlations(Shahs correlation and Cavallini-Zecchins correlation) were not suitable for small diameter tubes.

R407C 및 R410A의 수평원관내 응축열전달 (Condensation heat transfer of R407C and R410A in a horizontal smooth tube)

  • 서정현;김민수
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.633-641
    • /
    • 1999
  • Experiments were carried out to investigate the condensation heat transfer characteristics for R22 and its alternatives, R407C (R32/125/134a, 23/25/52wt%) and R410A (R32/125, 50/50wt%). A concentric tube heat exchanger was made to conduct condensation heat transfer tests. Mass flux and saturation temperature of refrigerants at the test section inlet were varied to get the corresponding heat transfer coefficients. Serial and parallel input of secondary fluid (water) were applied to the test subsections. Compared with existing correlations of condensation heat transfer, experimental heat transfer coefficients obtained in this study were generally higher than the predicted values, and mean absolute deviations from several correlations were shown. Wall subcooling was introduced to get a new correlation for condensation heat transfer coefficients by modifying Shah's equation. The RMS deviation of the measured heat transfer coefficients from the new correlation in this study for R22 is 9.9% and that for R407C and R410A are 10.2% and 14.6%, respectively.

  • PDF

핀-관 열교환기의 모델링 (Modeling of Fin-Tube Heat Exchanger)

  • 박희용;이관수;박동규
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.952-961
    • /
    • 1989
  • 본 연구에서는 널리 사용되는 핀-관 직교류 열교환기의 정상 상태를 예측 하기 위하여 냉매의 상변화에 따른 유체의 물성치, 열전달계수 및 마찰계수의 변화와 관벽에서의 축방향 열전도를 고려한 모형을 세우고 이를 분석하여 열교환기의 종합적 인 특성을 규명하고자 한다.

세관내 R-22와 R-410A의 응축 압력강하 (The Condensation Pressure Drop of R-22 and R-410A in Small Diameter Tube)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.156-162
    • /
    • 2008
  • The condensation pressure drop for R-22 and R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 mm length with horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes ranged from 450 to $1050\;kg/m^2{\cdot}s$ and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-22 is slightly higher than that of R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data.

낮은 핀을 가진 경사 써모사이폰의 열전달 성능에 관한 실험적 연구 (Experimental study on heat transfer inside inclined thermosyphon with low integral-fins)

  • 조동현;권혁홍
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.165-172
    • /
    • 1998
  • An experimental study on the heat transfer of the inclined thermosyphon with low integral-fins in which boiling and condensation occurred is performed to investigate its heat transfer performance. Water and CFC-30 have been used as the working fluids. The operating temperature and the inclination angle of thermosyphon have been used as the experimental parameters. The heat flux input and the inclination angle $\theta$ towards the vertical position were varied in steps. The heat transfer rate in the thermosyphon was depended upon the inclination angle. In addition, it is to obtain the overall heat transfer coefficients and the characteristics as a operating temperature for the practical applications.

  • PDF

홈이 파진 원판증발기를 가진 회전형 히트파이프에 대한 실험적 연구 (An Experimental Study on the Rotating Heat Pipe with a Grooved Disc Evaporator)

  • 권순석;장영석;유병욱
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.122-129
    • /
    • 1993
  • The heat transfer characteristics of the rotating heat pipe with a disc evaporator and a grooved condenser have been investigated by measuring temperature distributions of wall and vapor for various thermal inputs and revolutions per minute. The results showed that the heat transfer coefficients of all types are increased with thermal input and revolutions per minute. The heat transfer coefficient of evaporator with groove (pitch=2.5mm depth=1.5mm) is 25.8% higher than that of evaporator without groove at 500RPM, 150W.

  • PDF

경사 열사이폰의 절삭유 냉각성능에 관한 연구 (A Study on the Cooling Performance of Cutting Oil of Inclined Thermosyphon)

  • 이정한;이기백;조동현;이종선
    • 한국공작기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.38-44
    • /
    • 2002
  • An experimental investigation was performed to observe the cooling performance of cutting oil and the effect of inclination angle on the transport behaviour of a inclined thermosyphons with low integral-fins. Relatively high rates of heat transfer have been achieved by operating this manner. Water has been used as the working fluid. The inclimation angle of thermoryphon and the ratio of Reynolds number of cooling to hot fluid have been used as the experimental parameters. Heat transfer coefficients at the condenser and the evaporator are estimated from experimental results. The experimental results have been assessed and compared with existing theory. Good agreement with the theory of Yiwei has been found. The maximum heat flow rate in the thermosyphon proved to depend upon the inclination angle.

냉장고용 롤-플레이트형 휜-관 열교환기의 성능에 관한 연구 (A Study of Performance of Roll-plate type fin-tube Heat Exchanger for the Refrigerator)

  • 안성준;김종수;권오붕;박영종;하영주;최상조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2292-2297
    • /
    • 2008
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new type condenser which will cost less and will be as efficient as the spiral type. The new type condenser consists of a steel tube, steel plates and louver fins attached to the tube. The tube and the plate are bent into a single-passage serpentine shape.

  • PDF

과냉각수조에서 증기응축 특성에 관한 실험적 연구 (Experimental Study on Characteristics of Steam Condensation in a Sub-cooled Water Pool)

  • 김환열;조석;송철화;정문기;최상민
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.298-308
    • /
    • 1999
  • 과냉각수조로 분사되는 증기의 직접접촉 응축특성을 알아보기 위하여 다섯 개의 수평 노즐에 대해 증기 질량유량과 수조 온도를 여러 가지로 변화시키면서 실험적 연구를 수행하였다. 증기응축현상을 육안관찰과 고속 비디오 카메라를 사용한 방법으로 분석한 결과, 안정된 증기제트인 경우 증기 질량속과 수조온도가 변화함에 따라 타원형 및 원추형 증기제트 형상이 나타나는 것을 관찰하였다. 증기제트 팽창비, 증기제트 길이 및 응축연전달계수를 구하였고, 증기 질량속, 수조온도 및 노즐 내경이 미치는 영향을 분석하였다. 증기제트 길이와 응축열전달계수를 증기 질량속 및 응축추진 포텐셜의 함수로 나타낸 상관식을 구하였다. 증기제트 내부와 주위 수조온도 분포를 구했으며 증기 질량속, 수조온도 및 노즐 내경이 미치는 영향을 분석하였다. 처깅, 천이처깅, 응축진동, 안정응축, 방울응축진동 및 간헐진동응축 등 여섯 가지 영역으로 구분된 응축 영역도를 작성하였다. 그 외, 수조 벽면에서의 동압을 측정하였고, 증기 질량속과 수조온도에 따라 변화하는 증기 응축모드와 동압과는 밀접한 연관성이 있음을 확인하였다.

  • PDF

응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구 (A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser)

  • 한규일;조동현
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF