• Title/Summary/Keyword: 응축층

Search Result 71, Processing Time 0.027 seconds

Experimental Study of System Identification for Seismic Response of Building Structure (건축구조물의 지진응답제어를 위한 시스템 식별의 실험적 연구)

  • 주석준;박지훈;민경원;홍성목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.47-60
    • /
    • 1999
  • The stability and efficiency of structural control systems depend on the accuracy of mathematical model of the system to be controlled. In this study, state equation models of a small scale test structure and an AMD(active mass damper) are obtained separately using OKID(observer/Kalman filter identification) which is a time domain system identification method. The test structure with each floor acceleration as outputs is identified for two inputs - the ground acceleration and the acceleration of the moving mass of AMD relative to the installation floor - individually and the two identified state equation models are integrated into one by model reduction method. The AMD is identified with the motor control signal as an input and the relative acceleration of the moving mass as an output, and it is shown that the identified model has large damping ratio and phase shift. The transfer functions and the time histories reconstructed from the identified models of the test model and the AMD match well with those measured from the experiment.

  • PDF

A Passive Control of Interaction of Condensation Shock Wave anc Boundary Layer(II) (응축충격파와 경계층 간섭의 피동제어(II))

  • Choe, Yeong-Sang;Gwon, Sun-Beom;Kim, Byeong-Ji
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.329-340
    • /
    • 1997
  • A passive control of interaction of condensation shock wave / boundary layer for reducing the strength of condensation shock was conducted experimentally in a 2.5 * 8 cm$^{2}$ indraft type supersonic wind tunnel. The effects of following factors on passive control were investigated: 1) the thickness of porous wall, 2) the diameter of porous hole, and 3) the orientation of porous hole. On the other hand, the location of nonequilibrium condensation region and condensation shock wave was controlled by regulation of the stagnation conditions. Surface static pressure measurements as well as Schlieren observations of the flow field were obtained, and their effects were compared with the results the cases of without passive control. It was found that thinner porous wall, smaller porous hole and FFH orientation for the same cavity size and porosity of 12% are more favourable than the cases of its opposite.

Drag Reduction by Passive Control of Condensation Shock Wave in a Transonic Airfoil (천음속 익형에서 발생하는 응축충격파의 피동제어에 의한 항력 감소)

  • 백승철;최영상;권순범;이충원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.10-10
    • /
    • 1998
  • 천음속 익형에서 발생하는 응축충격파와 경계층의 간섭을 피동제어 하여 항력감소에 대한 연구를 2.5$\times$7$\textrm{cm}^2$ 천음속 풍동에서 수행하였다. 익형표면에 설치한 정압공으로 정압을, 익형후방에 설치한 8개의 Pitot probe로 전압을 동시에 측정하여 충격파를 통한 에너지의 손실과 항력의 변화를 계산하였고, 또한 유동장과 충격파의 형상을 가시화하기 위해 슈리렌 가시화 시스템을 사용하였다. 실험은 NACA 0012 익형에서 기공률 변화에 따른 피동제어의 항력감소 초과를 조사한 다음 NACA 64-018 익형에서는 기공률과 공동의 크기의 변화가 미치는 효과를 연구하였다. 피동제어의 개념은 충격파가 발생하는 하부벽을 다공벽으로 만들고 그 아래를 공동으로 만들면 충격파 후방의 상대적으로 높은 압력이 기류의 일부를 공동으로 자연스럽게 유입시키고 다시 공동에서 낮은 압력의 충격파 상류로 유출시키는 것이다.

  • PDF

Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes (세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성)

  • Son, Chang-Hyo
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • An experimental study to investigate the condensing heat transfer characteristics of small diameter horizontal double pipe heat exchangers with R-22 and R-410A was performed. Experimental facility was constructed to calculate and observe HTC(heat transfer coefficients), flow patterns and pressure drop. The main components include a liquid pump, an evaporator, a condenser(test section), a sight-glass, pressure taps and measurement apparatus. Two pipes of different diameters are tested; One 5.35 mm ID 0.5 mm thick, the other 3.36 mm ID 0.7 mm thick. The mass flow rate ranged from 200 to $500\;ks/m^2{\cdot}s$ and heating capacity were form 1.0 to 2.4 kW. The flow patterns of R-22 and R-410A were observed with a high speed camera through the sight-glass. The tests revealed that HTC of R-410A was higher than that of R-22 by maximum 5%. Annular pattern was observed for the most cases but stratified flow was also detected when x<0.2. The pressure drop in 3.36 mm ID pipe was higher than that of 5.35 mm by $30{\sim}50%$. Comparing with previous correlations such as Shah, Fujii and Soliman's, Fujii' showed the best good agreement with my data with a maximum deviation of 40%.

  • PDF

Ultrastructural Changes in the Mantle of the Equilateral Venus, Gomphina veneriformis (Bivalvia: Veneridae) Exposed to TBTCl (TBTCl 노출에 의한 대복, Gomphina veneriformis (Bivalvia: Veneridae) 외투막의 미세구조적 변화)

  • Park, Jung-Jun;Kim, Seok-Ryel;Park, Myoung-Ae;Lee, Jung-Sick
    • The Korean Journal of Malacology
    • /
    • v.27 no.3
    • /
    • pp.213-221
    • /
    • 2011
  • Equilateral venus, Gomphina veneriformis exposed to tribultyltin chloride (TBTCl) for 36 weeks was showed ultrastructural changes of the mantle. The fine mantle had 4-folds and its epidermal layer consisted of simple columnar epithelial cells and ciliated cells and secretory cells. Inner and outer epidermal layer covered connective tissue. The mantle exposed to TBTCl at 12 weeks was decreased cilia in the inner epidermal layer, and observed extension of the hemolymph sinus and destruction of the septum. At 20 weeks, it revealed vacuole formation and pycnosis in the cytoplasm, and scattered muscular fiber. After 28 weeks of exposure, the mantle revealed partially degenerative changes in the epidermal layer. In the ciliated cells, basal body was isolated from the cilia and rootlet complex and basal foot were scattered. The sarcolemma had debris fiber. At 36 weeks, it observed degenerative cells that it revealed disappearance of the cilia, atrophic nucleus, poorly membrane and destruction of the cresternae in the mitochondria, and increasing heterophagosome. The outer epithelial cell had necrotic nuclus, numeous lysosome and disappearance of the microvilli. Therefore, results of this study suggested that chronical TBTCl exposure in the Gomphina veneriformis induced the disorders of shell growth and physiological function with histopathological changes of the mantle.

Development of Efficient Analytical Model for a Diagrid Mega-Frame Super Tall Building (다이어그리드 메가프레임 초고층 건물을 위한 효율적인 해석모델의 개발)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.3
    • /
    • pp.95-103
    • /
    • 2011
  • Among structural systems for complex-shaped tall buildings, diagrid system is widely used because of its structural efficiency and beauty of form. Recently, mega frame is favorably employed as a suitable structural system for skyscrapers because this structural system has sufficient stiffness against the lateral forces by combination of mega members which consist of many columns and girders. Diagrid mega frame system is expected to be promising structural system for future super tall buildings. However, it takes tremendous analysis times and engineer's efforts to predict the structural behavior of tall buildings applied with diagrid mega frame system because the diagrid mega frame structure has significant numbers of elements and nodes. Therefore, efficient analytical method for all buildings applied with diagrid mega frame system has been proposed in this study to reduce the efforts and time required for the analysis and design of diagrid mega frame structure. To this end, an efficient modelling technique using the characteristics of diagrid mega frame structures and an efficient analytical model using minimal DOFs by the matrix condensation method were proposed in this study. Based on the analysis of an example structure, the effectiveness and accuracy of the proposed method have been verified by the comparison between the results of the proposed method and the conventional method.

Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper (준능동 TMD를 이용한 메가골조구조물의 진동제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.57-68
    • /
    • 2007
  • The mega frame system is becoming popular for the design and construction of skyscrapers because this system exhibits structural efficiency by allowing high rigidity of the structure while minimizing the amount of structural materials to be used. Since the mega frame system is usually adopted for super high-rise buildings, the comfort of occupants may be main concerns in the practical application of this system. For the enhancement of the serviceability of mega frame structures, a semi-active tuned mass damper (STMD) is developed in this study. To this end, a Magnetorheological (MR) damper is employed replacing passive damper as a semi-active damper to improve the control effect of a conventional TMD. Since a conventional finite element model of mega frame structures has significant numbers of DOFs, numerical simulation for investigation of control performances of a STMD is impossible by using the full-order model. Therefore, a reduced-order system using minimal DOFs, which can accurately represent the dynamic behavior of a mega frame structure, is proposed in this study through the matrix condensation technique To improve the efficiency of the matrix condensation technique, multi-level matrix condensation technique is proposed using the structural characteristics of mega frame structures. The efficiency and accuracy of the reduced-order control proposed in this study and the control performance of a STMD were verified using example structures.

Fine Structural Modification of Mouse Ovarian Tissue by Irradiation of 6 MeV LINAC Radiation (6 MeV LINAC 방사선 조사에 의한 생쥐 난소조직의 미세구조 변화)

  • Yoon, Chul-Ho;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.33 no.2
    • /
    • pp.117-130
    • /
    • 2003
  • This research investigates the fine structural as well as the morphological changes of the mouse ovarian tissue after irradiation of various dose rates of 6 MeV LINAC radiation. The normal structure of the ovarian tissue is consisted of various stages of follicles including primordial and growing follicles, and ovarian stromal connectives. When we observed the ovarian tissues irradiated with a dose rate of 200 cGy/min using light and electron microscopes, granular cells in growing follicles are in irregular shape unlike normal follicles. Small segments of cells scattered in follicular antrum among granular cells. We could observe neutrophils and macrophages around the segments, which means the cells already got in the process of decease owing to the effects radiation. With coincident to the increase of the dose rate of x-ray irradiation as 400 or 600 cGy/min, the mature follicles appeared as an irregular form and the granular cells surrounding oocyte also deformed comparing to their normal counterparts. The granulosa cells within mature follicle are already occurred necrotic change and apoptosis. The nuclei in some cells got so fragmented that the segments formed the shape of a horseshoe or scattered in small and condensed pieces. All the cells at a granular layer irradiated with a dose rate of 600 cGy/min show typical characteristics of apoptosis. The neutrophils involved in inflammatory reaction appear evidently in follicular antrum of growing follicles, and macrophage scattered with residual and apoptotic bodies.

TCE degradation by a photocatalysis in the annular flow & the annulus fluidized bed photoreactor (애뉼러 흐름 및 애뉼러스 유동층 광반응기에서 Trichloroethylene 의 광촉매 분해반응 특성)

  • 임탁형;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.11a
    • /
    • pp.161-164
    • /
    • 2002
  • 대기로 배출되는 휘발성 유기화합물 중의 하나인 TCE (Trichroloethylene)를 제거하는 기술들은 설치비 및 운전비가 많이 요구되는 흡착, 응축, 소각기술 들이 있으며, 이를 대체하는 신기술로 광촉매 반응으로 유기휘발물을 상온과 상압에서 광반응시켜 제거함으로서, 설치 및 조업비 측면에서 경제적인 이점이 있다.(중략)

  • PDF

Evaluation of the Mist Diffusion Layer Condensation Heat Transfer Model with a Non-condensable Gas Present (불응축성 기체 환경에서의 연무/확산 경계층 응축열전달 모델 평가)

  • 변층섭;이재용;이창섭
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.371-376
    • /
    • 2003
  • 원자력 발전소에서 격납건물 계통의 건전성 유지는 냉각재상실사고(Loss of Coolant Accident: LOCA) 및 주증기관 파단(Main Steam Line Break : MSLB) 사고와 같은 설계기준사고 시 격납건물의 최대 온도/압력을 평가하는 격납건물 성능 평가는 격납용기 내에 방사능 물질을 효율적으로 가두어 방사능 피해로부터 공공의 안전을 확보할 수 있느냐 하는 관건이다.(중략)

  • PDF