• Title/Summary/Keyword: 음영 효과

Search Result 114, Processing Time 0.026 seconds

Effects of Correlated Local Spectrum Sensing Decisions on the Throughput of CR Systems (스펙트럼 감지 결정간의 상관 관계가 CR 시스템의 전송 용량에 미치는 영향)

  • Lim, Chang-Heon;Lee, Sang-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1A
    • /
    • pp.87-94
    • /
    • 2010
  • It is widely known that cooperative spectrum sensing in which secondary users scattered in some region collaborate to detect primary users can significantly reduce the performance degradation due to the fading phenomenon. Most of previous works on cooperative spectrum sensing are based on the assumption that the local spectrum sensing decisions of secondary users are statistically independent. However, there can be practically some statistical correlation between the local decisions of any two secondary users in close proximity, which is caused by shadowing effect. In order to evaluate the effect of this correlation on the performance of collaborative spectrum sensing, we assumed that, for the case that a primary user are active in the spectrum of interest, any two local decisions are statistically correlated to each other with some level of constant correlation and independent otherwise, and analyzed the achievable throughput with the degree of correlation varying. The results showed that, as the degree of correlation gets higher, the throughput increases for the case of the AND fusion rule and decreases for the OR fusion rule.

The Effect of Radiation Therapy on Oligodendrogliomas (회돌기교종의 방사선치료 효과)

  • Yoon Sei Chul;Kim Sung Whan;Chung Soo Mi;Gil Hok Jun;Shinn Kyung Sub;Bahk Yong Whee;Kang Joon Ki;Song Jin Un
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 1991
  • From April,1983 through April,1989, we have treated histologically proven 21 patients with oligodendroglioma using 6 MV linear accelerator at the Division of Radiation Therapy, Kangnam 51. Mary's Hospital Catholic University Medical College. These are 8% of the irradiated 246 primary brain tumors during the same period. To investigate influencing factors on the survival of irradiated U patients with oligodendroglioma, we analyzed the cerebral location of the involvements, initial symptoms, CT findings and survival rates, retrospectively. One case was lost to follow up and excluded from survival data. Of the 28 patients, thirteen were male and 8 female. Ages ranged from 5 to 68 years with a median age of 38 years. Radiation doses varied from 3900 cGy to 0480 cGy and were given for 5 to 8 weeks. All but one were supratentorial. The involvement of the frontal and parietal lobes were 10 (48%) patients in each and temporal lobe in 8 (38.1%). Histological diagnosis was made by stereotactic biopsy in 3 and postoperatively in 18. The type of surgery was divided into partial, subtotal and total resection in 7,9 and 2 cases respectively. In 6 cases, chemotherapy was also tried during or after radiation therapy. Major presenting symptoms were headache, cerebral motor, nausea & vomiting and epilepsy in 18,12, 7 and 5 respectively in decreasing order. In CT analysis, low density (02%), cystic mass (33%), calcifiestion (66%) and positive contrast enhancement (42.8%) were observed as the highest frequency. Mean survival duration after radiation therapy was 38 months (K-M methods). We could not achieve statistically significant factors influencing on the survival rate after radiation therapy for oligodendrogliomas by one or two tail test.

  • PDF

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

The Evaluation of IL-8 in the Serum of Pneumoconiotic patients (진폐증 환자에서의 혈청내 IL-8 농도)

  • Ahn, Hyeong Sook;Kim, Ji Hong;Chang, Hwang Sin;Kim, Kyung Ah;Lim, Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.945-953
    • /
    • 1996
  • Background : Many acute and chronic lung diseases including pneumoconiosis are characterized by the presence of increased numbers of activated macrophages. These macrophages generate several inflammatory cell chemoattractants, by which neutrophil migrate from vascular compartment to the alveolar space. Recruited neutrophils secrete toxic oxygen radicals or proteolytic enzymes and induce inflammatory response. Continuing inflammatory response results in alteration of the pulmonary structure and irreversible fibrosis. Recently, a polypeptide with specific neutrophil chemotactic activity, interleukin-8(IL-8), has been cloned and isolated from a number of cells including : monocytes, macrophages and fibroblasts. IL-1 and/or TNF-${\alpha}$ preceded for the synthesis of IL-8, and we already observed high level of IL-1 and TNF-${\alpha}$ in the pneumoconioses. So we hypothesized that IL-8 may be a central role in the pathogenesis of pneumoconiosis. In order to evaluate the clinical utility of IL-8 as a biomarker in the early diagnosis of pneumoconiosis, we investigated the increase of IL-8 in the pneumoconiotic patient and the correlation between IL-8 level and progression of pneumoconiosis. Method : We measured IL-8 in the serum of 48 patients with pneumoconiosis and 16 persons without dust exposure history as a control group. Pneumoconiotic cases were divided into 3 groups according to ILO Classification : suspicious group(n=16), small opacity group(n=16) and large opacity group(n=16). IL-8 was measured by a sandwich enzytne immunoassay technique. All data were expressed as the $mean{\pm}standard$ deviation. Results: 1) The mean value of age was higher in the small opacity and large opacity group than comparison group, but smoking history was even. Duration of dust exposure was not different among 3 pneumoconiosis groups. 2) IL-8 level was $70.50{\pm}53.63pg/m{\ell}$ in the suspicious group, $107.50{\pm}45.88pg/m{\ell}$ in the small opacity group, $132.50{\pm}73.47pg/m{\ell}$ in the large opacity group and $17.85{\pm}33.85pg/m{\ell}$ in the comparison group. IL-8 concentration in all pneumoconiosis group was significant higher than that in the comparison group(p<0.001). 3) IL-8 level tended to increase with the progression of pneumoconiosis. Multiple comparison test using Anova/Scheffe analysis showed a significant difference between suspicious group and large opacity group(p<0.05). 4) The level of IL-8 was correlated with the progression of pneumoconiosis(r=0.4199, p<0.05). Conclusion : IL-8 is thought to be a good biomarker for the early diagnosis of pneumoconiosis.

  • PDF

Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography (치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과)

  • Lee, Tae Hui;Jeong, Seung Hun;Kim, Dong Woo;Park, Myeong Hwan;Kim, Tae-Hyung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.459-464
    • /
    • 2019
  • In order to minimize the radiation exposure dose of the thyroid site at dental cone-beam computer tomography, a protector using a Bolus was prepared, and the radiation shielding effect and the appropriateness of the image were evaluated. Using a dental cone-beam computed tomography (CBCT), a glass dosimeter was attached to the left and right sides of the thyroid for a dental radiation phantom, and the radiation dose was measured. The absorbed dose for each shield was measured by another method to 10 mm, 20 mm, and 30 mm-thickness, respectively. Eight evaluators evaluated whether or not the medical image is appropriate. When using a 30 mm Bolus shield at the left thyroid site, the resulting value is reduced by an average of $342.67{\mu}Gy$ by 20.7% from the average value of $431.22{\mu}Gy$ measured without using a Bolus shield, the right thyroid site In the case of using 30 mm Bolus shield, it showed a dose reduction effect of 21.9% with an average of $424.56{\mu}Gy$. The adequacy of the medical image was judged to be usable by both evaluators. In conclusion, the dental cone-beam computerized tomography can be used as a useful shielding material because it has a radiation shielding effect and it is possible to treat the diagnosis of the bolus protector in the thyroid without any obstruction shade in order to minimize the radiation dose.

Analyzing Driving Behavior, Road Sign Attentiveness and Recognition with Eye Tracking Data (운전자 시각행태 및 주행행태 분석기반의 결빙주의표지 개발연구)

  • Lee, Ghang Shin;Lee, Dong Min;Hwang, Soon Cheon;Kwon, Wan Taeg
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.6
    • /
    • pp.117-132
    • /
    • 2021
  • Due to the terrain in Korea, there are many road sections passing through mountainous areas. During the winter, there is a higher risk of traffic accidents, due to black ice caused by the lack of sunlight. Despite domestic road freezing safety measures, accidents caused by road freezing results in severe traffic accidents. Under these considerations, this study analyzed whether traffic safety signs that change in response to the external temperature help drivers recognize frozen road segments. The study was conducted through analysis of the effect of the signs on a driver's perspective. For the signs under development, out of the signs designed by experts, the sign design which received the highest visibility and effectiveness evaluation ratings from the general public was selected. The sign was implemented through Virtual Reality (VR) and installed on the right side of the road to analyze the effect on gazing and driving behavior. As a result of analyzing the driver's driving behavior, a speed reduction of about 7km/h or more was found in the sign section. Therefore, It was found that the existence of the sign had a strong relationship with the rate of the drivers' speed reduction.

Link Performance Analysis for Intra-Aircraft Wireless Communications in 4.4GHz (4.4GHz 대역을 활용한 항공기내 무선통신 링크 성능 분석)

  • Cho, Moon-Je;Jung, Bang Chul;Park, Pangun;Chang, Woohyuk;Ban, Tae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1243-1248
    • /
    • 2016
  • This paper investigated the channel link budget for Wireless Avionics Intra-Communication (WAIC) in 4.4GHz. The band 4.2~4.2GHz was allocated for the communication service among aeronautical applications in world radiocommunication conference (WRC). Wireless channels in aircraft was modelled by the combination of path loss, shadowing effect caused by obstacles, and fading caused by multipath signals. In addition, wireless channels in aircraft are categorized into 6 groups according to various locations of transmitter and receiver. We analyzed the channel link budget for the 6 channel groups in terms of maximum transmission distance and outage probability. Our analysis and intensive computer simulation results show that the propagation characteristics of group A, B, and F is superior to group C, D, E, and the propagation of group E is the most vulnerable. Also, these results can be utilized as basic reference for the channel analysis of intra-aircraft or similar environment.

A Ray-Tracing Algorithm Based On Processor Farm Model (프로세서 farm 모델을 이용한 광추적 알고리듬)

  • Lee, Hyo Jong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 1996
  • The ray tracing method, which is one of many photorealistic rendering techniques, requires heavy computational processing to synthesize images. Parallel processing can be used to reduce the computational processing time. A parallel algorithm for the ray tracing has been implemented and executed for various images on transputer systems. In order to develop a scalable parallel algorithm, a processor farming technique has been exploited. Since each image is divided and distributed to each farming processor, the scalability of the parallel system and load balancing are achieved naturally in the proposed algorithm. Efficiency of the parallel algorithm is obtained up to 95% for nine processors. However, the best size of a distributed task is much higher in simple images due to less computational requirement for every pixel. Efficiency degradation is observed for large granularity tasks because of load unbalancing caused by the large task. Overall, transputer systems behave as good scalable parallel processing system with respect to the cost-performance ratio.

  • PDF

Radiation Effect on Airway Obstruction from Lung Cancer (폐암으로 유발된 무기폐에 대한 방사선 치료의 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.121-125
    • /
    • 1989
  • Total 21 patients with airway obstruction from lung cancer treated with radiotherapy at Department of Therapeuctic Radiology, Yeungnam University College of Medicine, between April 1986 and December 1988 are retrospectively analysed by means of roentgenologic findings. Obtained results are as follows. 1. 15 out of 21 patients(71%) showed complete or partial response. 2. Patients with small cell lung cancer showed 100% response in spite of low dose(30GY/10 fractions). 3. Patients with non-small cell lung cancer treated with 50GY or over showed better response than below 45GY or below. 4. There is no relationship between the response and site of airway obstruction. These data suggested that high dose irradiation is more effective in the management of airway obstruction from lung cancer and meticulous radiotherapy planning with appropriate protection of normal lung and critical organs should be investigated in order to maximize radiation effect and minimize side effect, complication or sequelae.

  • PDF

Scattered Light Representation in Accordance with the Material Using Scatterer Template in Volume Rendering (볼륨 렌더링에서 산란자 템플릿을 이용한 재질별 산란광 표현)

  • Lee, Byeong-Joon;Kwon, Koojoo;Shin, Byeong-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.12
    • /
    • pp.677-684
    • /
    • 2016
  • For realistic rendering volume to calculate the light effects as well as the shade is essential. In order to produce the high quality of the resulting image, it is necessary to represent a global illumination, and it should be considered an indirect effect of the direct impact and scattering of light. It requires a lot of resources in order to perform this operation and, in particular, is very expensive when large amounts of data to be rendered as a volume data is consumed. In this paper, we generate a scatterer template according to the physical laws for each material. Considering that each object having material property stores photons of the template based on the Lambert illumination model. When the volume rendering in this paper, using the photon is stored in the template, based on the voxel to be sampled within the examination volume occluded, and it represents the global illumination of the scattering. Because the materials produced by the template requires a less resource only if comprised of a complex material, a simple operation can be expressed within the scattering volume at a low cost through.