• Title/Summary/Keyword: 음(-)의 감쇠

Search Result 23, Processing Time 0.019 seconds

Comparison of IIR Filter and Wavelet Filter on Acoustic Decay Measurements (음 감쇠 측정에서의 IIR 필터와 웨이블렛 필터의 영향에 대한 수치 계산, 비교)

  • 이상권;이민성;김봉기
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.5-13
    • /
    • 2001
  • It is well known that there are two experimental errors on acoustic decay measurements. ,One is due to the influence of the band pass filter the other one is that of an averaging device. In this paper the influence of the filter is investigated in detail. To minimize the influence of the filter, the product of the filter bandwidth B (3dB bandwidth) and the reverberation time T/sub 60/ of the room under test should be at least 16. Moreover, if the initial part of an acoustic decay curve is important, the strong requirement, i. e. BT/sub 60/〉64, must be satisfied. In this paper, the wavelet filter bank instead of the band pass filter bank is applied to obtain an acoustic decay curve. As a result, the influence of filter is reduced and then the value of BT/sub 60/ required for obtaining an acceptable decay curve becomes at least 4. The strong requirement for the initial part of a decay curve is also replaced by the BT/sub 60/〉16 instead of BT/sub 60/〉64.

  • PDF

Acoustic characteristics of pacific white-sided dolphin sound observed in the middle coast of Donghae (동해중부연안에서 관측된 흰줄무늬 돌고래 발생음의 음향 특성)

  • 김봉채
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.51-54
    • /
    • 1996
  • 동해 중부 연안(수심: 200 m)에서 해수 중 주위잡음을 측정하는 동안 태평양 흰줄무늬 돌고래(pacific white-sided dolphin, 학명: Lagenorhynchus obliquidens)의 발생음을 수신하였으며 그 음향 특성을 분석하였다. 그 결과 얻어진 결론을 요약하면 다음과 같다. 첫째, 돌고래 발생음의 파형은 임펄스의 형태로서 그것의 전체 길이는 0.25~60.50 ms였고, 처음에 음(-)의 방향으로 작은 진폭을 보였으며, 그 후 작은 진폭으로 빠르게 감쇠진동하고 있는 형태를 나타내었다. 둘째, 돌고래 발생음의 주파수 스펙트럼은 약 18~90kHz의 광범위한 성분을 포함하고 있었다. 셋째, 돌고래 발생음의 스펙트럼 레벨 피크는 주파수 범위 35~55 kHz에서 나타났으며, 이것은 돌고래의 발생음이 없는 경우 해수 중 주위잡음의 레벨에 비하여 약 30~40 dB 높게 나타났다.

  • PDF

Design of Multi-Channel Sound Field Reproduction (멀티 채널 음장 재생 시스템의 설계)

  • 김영오
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.265-268
    • /
    • 1998
  • 본 논문에서는 1채널(mono)이나 2채널(stereo)의 오디오 입력을 5채널(center, left, right, left side, right side)로 출력시키는 음장 시스템을 설계하고 그 성능을 분석하였다. 가정의 리스닝 룸 같이 작은 공간에서 콘서트 홀 같은 커다란 공간의 음장을 재현하기 위한 멀티 채널 음장 시스템은 지연기, 초기 반사음처리기, 잔향기를 이용해 설계하였다. 초기 반사음 처리기의 지연과 이득은 실제 공간에서 측정한 암펄스 응답을 이용하여 결정하였으며, 구현된 초기 반사음을 전방 30$^{\circ}$방향에서 재생함으로써 확장감을 증가시킬 수 있도록 하였다. 잔향기는 자연스러운 주파수 및 감쇠 특성을 갖도록 설계되었으며, 후방 60$^{\circ}$방향에서 재생되는 잔향의 상관 계수를 작게 함으로써 청취시 공간감을 느끼게 하였다. 설계된 음장 시스템은 무향실 데이터를 입력으로 시뮬레이션되었고, 그 결과로 얻어진 5개의 PCM 출력은 멀티 트랙 재생 장치에 의해 일반 리스닝 룸에서 재생된다.

  • PDF

Evaluating Speech Intelligibility of Lecture Rooms Using Temporal Factors in Autocorrelation Function(ACF) (ACF의 시간적 요소에 의한 강의실 요해도 평가)

  • Kim Jeong Mi;Jeon Jin Yong
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.271-274
    • /
    • 2001
  • 강의실의 언어 요해도에 관한 연구는 그 평가방법과 지표에 대한 주제로 꾸준히 이루어져 왔다. 기존의 지표들에서는 전체 음에너지에 대한 초기음에너지의 비율로 계산하거나(C80, D50) 주파수 대역별 음에너지의 감쇠율(RASTI)을 구하여 명료도를 평가하였다. 본 연구에서는 Autocorrelation Function (ACF)의 시간적 요소를 통해 강의실의 언어 요해도를 평가하였다. 먼저 시뮬레이션 대상 강의실에서 무향실 음원이 제시되었을 때 12개 수음점에서 음향특성을 측정$\cdot$분석하였으며 청감실험과 ACF 분석을 통해 강의실 요해도와의 상관관계 규명하였다

  • PDF

A study on sound source segregation of frequency domain binaural model with reflection (반사음이 존재하는 양귀 모델의 음원분리에 관한 연구)

  • Lee, Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.3
    • /
    • pp.91-96
    • /
    • 2014
  • For Sound source direction and separation method, Frequency Domain Binaural Model(FDBM) shows low computational cost and high performance for sound source separation. This method performs sound source orientation and separation by obtaining the Interaural Phase Difference(IPD) and Interaural Level Difference(ILD) in frequency domain. But the problem of reflection occurs in practical environment. To reduce this reflection, a method to simulate the sound localization of a direct sound, to detect the initial arriving sound, to check the direction of the sound, and to separate the sound is presented. Simulation results show that the direction is estimated to lie close within 10% from the sound source and, in the presence of the reflection, the level of the separation of the sound source is improved by higher Coherence and PESQ(Perceptual Evaluation of Speech Quality) and by lower directional damping than those of the existing FDBM. In case of no reflection, the degree of separation was low.

Backscattering from Seagrass beds (잘피의 후방산란 특성)

  • La Hyoung-sul;Yoon Kwan-seob;Lee Jae-hyuk;Na Jungyul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.191-194
    • /
    • 2004
  • 본 연구에서는 해양의 기초 생산자인 잘피 (Zostera marina)의 후방산란 특성을 일주기 동안 관측 하였다. 해상 실험은 2004년 2월 $25\~29$일 기간 중 남해 동대만에서 실시 하였다. 그랩(Grab)을 이용하여 해초지의 입도를 분석 하였으며 주파수별 산란 특성을 고려하기 위해서 17, 30, 50, 80, 100, 그리고 120kHz 음원을 해초지에 수직 지향하여 주, 야간 잘피의 후방 산란을 측정하였다. 실험 환경 분석을 위해 파고와 조석 및 잘피의 생체량(biomass)측정을 실시 하였다. 광합성 시 해초지에서 발생되는 산소 공기는 해수에 의해 용존 되거나 산소 가스 형태로 존재하게 된다. 이들 공기 방울에 의해서 형성되는 공기 방울 층은 음 세기의 감쇠를 야기 시킨다. 실험 결과 주, 야간 동안 음의 산란 강도 변화를 확인 하였다.

  • PDF

Sound Attenuation Coefficients and Biogenic Gas Content in the Offshore Surficial Sediments Around the Korean Peninsula (韓半島 周邊海域 海底 表層蓄積物 音波 空曠係數와 생物起源 氣滯含量)

  • 김한준;덕봉철
    • 한국해양학회지
    • /
    • v.25 no.1
    • /
    • pp.26-35
    • /
    • 1990
  • Sound velocities and attenuation coefficients of marine surface sediments were calculated from insitu acoustic experiments on 4 nearshore areas off Pohang, Pusan Yeosu, and Kunsan around the Korean Peninsula. The relationship between these values and physical properties of sediments was examined and attenuation mechanism was analysed using the estimated gas content. Sound velocities and attenuation coefficients ranging from 1470 to 1616 m/sec and 0.0565 to 0.6604 dB/kHz-m, respectively, are well related to sediment types. The attenuation coefficient is maximum in coarse silts, and the sound velocity increases with density. The gas content estimated less than 8 ppm increases with the decreasing sediment grain size. When the sediment size is greater than fine sand, sound attenuation is mostly due to friction losses, and probably negligible viscous loss remains unchanged with the varying physical properties of sediments. The maximum attenuation in coarse silts result from both friction loss and cohesion of finer sediments between the contacts of silt grains. The cohesion begins to be the dominant dissipative process with decreasing grain size from medium and fine silts.

  • PDF

특정 실험실 조건에서의 사무실용 낮은 칸막이의 소음감쇠성능 측정방법 KS제정을 위한 ISO 규격내용 분석

  • Yang, Kwan-Seop;Jeong, Seong-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.21-24
    • /
    • 2006
  • 대부분의 사무용 건물은 코아 부분(엘리베이터 홀, 화장실, 계단 등)을 제외하고는 Open 되어 있으며, 필요에 따라 부서간에는 천장 면까지 도달하는 경량벽체를 설치하여 독립된 공간을 구획하고, 부서내부에서는 직원들간의 커뮤니케이션은 용이하게 하는 대신에 최소한의 독립성을 제공하기 위해 낮은 칸막이 등을 설치하고 있다. 그러나 사무실에 사용하는 칸막이 벽체 중 천장 면까지 도달하는 칸막이에 대해서는 KS F 2808(건물 부재의 공기전달음 차단성능 실험실 측정방법)의 측정방법을 이용하여 차음성능을 확인할 수 있으나 낮은 칸막이에 대해서는 소음저감 성능을 측정할 수 있는 측정 방법에 관한 규격이 없다. 따라서 기존에 있는 모든 KS 규격들은 국제표준규격인 ISO와의 부합화가 이루어졌거나 이루어지고 있기 때문에 이러한 정부의 방침에 따라 본 낮은 칸막이에 대한 소음감쇠량 측정규격 또한 ISO규격(ISO 10053(음향- 실험실 조건에서의 사무실 스크린의 소음저감성능 측정방법))을 받아들이기 위해 ISO규격 내용을 검토하였다. 향후 이 규격이 그대로 우리나라 규격으로 제정될 때 나탈 수 있는 문제점을 최소화하기 위해 국내에 있는 반 무향실에서 낮은 칸막이의 실제 소음저감 성능을 실시할 계획이다.

  • PDF

The dynamic stiffness of resilient materials for floor impact sound according to temperature change (온도변화에 따른 바닥충격음 완충재의 동탄성계수 변화)

  • Yeon, Junoh;Goo, Heemo;Lee, Sungchan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.338-342
    • /
    • 2018
  • In order to solve the floor impact sound problem in the upper and lower floors, the Ministry of Land, Transport and Maritime Affairs also notifies the physical properties of the resilient material affecting the floor impact sound level. The dynamic modulus of elasticity and the loss factor before and after heating are most related to the floor impact noise, especially for the cushioning material. Therefore, in this study, the rate of change with respect to the dynamic modulus and loss factor with temperature change was examined by increasing $10^{\circ}C$ by $10^{\circ}C$ from the temperature condition of $70^{\circ}C$ specified in the standard. The dynamic modulus of elasticity and the loss modulus were measured by using the pulse excitation method for eight kinds of samples. The calculation method was calculated by the time series analysis method using the damped vibration waveform.

US Attenuation Imaging for the Evaluation and Diagnosis of Fatty Liver Disease (지방간 질환 진단을 위한 초음파 감쇠 영상 평가)

  • Seung Jun Lee;Youe Ree Kim;Young Hwan Lee;Kwon-Ha Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.666-675
    • /
    • 2023
  • Purpose This study aimed to determine whether the attenuation coefficient (AC) from attenuation imaging (ATI) was correlated with visual US assessment in patients with hepatic steatosis. Moreover, it aimed to assess whether the patient's blood chemistry results and CT attenuation were correlated with AC. Materials and Methods Patients who underwent abdominal US with ATI between April 2018 and December 2018 were included in this study. Patients with chronic liver disease or cirrhosis were excluded. The correlation between AC and other parameters, such as visual US assessment, blood chemistry results, liver attenuation, and liver-to-spleen (L/S) ratio, were analyzed. AC values according to visual US assessment grades were compared using analysis of variance. Results A total of 161 patients were included in this study. The correlation coefficient between US assessment and AC was 0.814 (p < 0.001). The mean AC values for the normal, mild, moderate, and severe grades were 0.56, 0.66, 0.74, and 0.85, respectively (p < 0.001). Alanine aminotransferase levels were significantly correlated with AC (r = 0.317, p < 0.001). The correlation coefficients between liver attenuation and AC and between L/S ratio and AC were -0.702 and -0.626, respectively (p < 0.001). Conclusion Visual US assessment and AC showed a strong positive correlation with the discriminative value between the groups. Computed tomography attenuation and AC showed a strong negative correlation.