• Title/Summary/Keyword: 윤민혁

Search Result 8, Processing Time 0.019 seconds

Syringomatous Adenoma of the Nipple on Screening Mammography: A Case Report (선별 유방촬영술에서 발견된 유두의 한선 종양: 증례 보고)

  • Min Hyeok Yoon;Hye Jung Kim;Won Hwa Kim;Jeeyeon Lee;Ji-Young Park;Jin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1565-1569
    • /
    • 2021
  • Syringomatous adenoma of the nipples, first reported in 1983, is an extremely rare benign tumor extending to the subareolar area and, pathologically, has a shape similar to that of sweat gland tumors. Radiologically, infiltrating patterns and calcifications can cause misdiagnosis of malignant tumors. The authors report a case of syringomatous adenoma that shows only calcifications of the nipple in a screening mammography.

Bioequivalence of Cefaclor 375 mg SR Tablet (세파클러 375 mg서방정의 생물학적 동등성)

  • Lee, Shin Hwa;Yun, Min Hyuk;Choi, Kyung Eob;Kwon, Kwang Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.13 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • This study was carried out to compare the bioavailability of $Ceclex^{(R)}$ SR TAB (test drug, cefaclor 375 mg/Tablet) with that of Ceclor $MR^{(R)}$ SR IAB (reference drug) and to estimate the pharmacokinetic parameters of cefaclor in healthy Korean volunteers. The bioavailability was examined on 24 healthy volunteers who received a single dose (375 mg) of each drug in the fasting state in a randomized balanced 2-way crossover design. After dosing, blood samples were collected for a period of 7 hours. Plasma concentrations of cefaclor were determined using HPLC with UV detection. The pharmacokinetic parameters $(AUC_{0-7h},\;C_{max},\;T_{max},\;AUC_{inf},\;K_e,\;t_{1/2},\;V_d/F,\;and\;CL/F)$ were calculated with non-compartmental pharmacokinetic analysis. The ANOVA test was utilized for the statistical analysis of the $T_{max}$, log-transformed $AUC_{0-7h$}$, log-transformed $C_{max},\;t_{1/2},\;V_d/F$, and $CL/F$. The ratios of geometric means of $AUC_{0-7h}\;and\;C_{max}$ between test drug End reference drug were $95.67\%\;(8.55\;vs\;8.18{\mu}g{\cdot}hr/ml)\;and\;103.86\%\;(2.85\;vs\;2.96{\mu}g/ml)$, respectively. The $T_{max}$ of test drug and reference drug was $2.56\pm0.15\;and\;2.23\pm0.13\;hrs,\;respectively.\;The\;90\%$ confidence intervals of mean difference of logarithmic transformed $AUC_{0-7h}\;and\;C_{max}$ were log0.90-log1.04 and log0.91-log1.13, respectively. It shows that the bioavailability of test drug is equivalent with that of reference drug.

  • PDF

Pharmacokinetics of a New Histone Hl Protein (p961), an Arthritis-suppressing Agent, in Rats and Rabbits (항류마치스 효과를 갖는 새로운 히스톤 H1 단백질 (p961)의 흰쥐와 토끼에 대한 약물동태)

  • 우수경;윤민혁;이재흥;권광일
    • YAKHAK HOEJI
    • /
    • v.45 no.4
    • /
    • pp.378-386
    • /
    • 2001
  • A purified histone Hl protein, p961, which plays a role in mediating the condensation of DNA into chromatin, was recently proved as an arthritis-suppressing agent in the mouse CIA model. The pharmacokinetics of p961 was carried out in rats and rabbits. The rat's blood, bile and urine samples were serially collected from the femoral vein, common bile duct, and bladder respectively, after bolus i.v. injection at low (10 mg/kg) and high (30 mg/mg) doses. The rabbit's blood samples were also collected from the marginal ear vein after bolus i.v. injection at a dose 10 mg/kg. p961 and its major metabolite in the physiological samples were analyzed by reverse-phase HPLC using a Yydac C4 protein column and a multistep water-acetonitrile gradient containing 0.24% trifluoroacetic acid. The major pharmacokinetic parameters (AUC, $C_{max}$, MRT, $t_{1}$2/, $V_{ss}$ and Cl) were estimated from the time course of plasma p961 and metabolite concentrations using WinNonlin. A two-compartment model was chosen for p961 as the most appropriate pharmacokinetic model. After i.v. injection of p961 at doses of 10 mg/kg and 30 mg/kg, more than 80% of p961 was removed rapidly from the plasma within 15 min. The plasma half-life of p961 in rats and rabbits was found not to exceed 12 min. p961 (22448.9 mol wt) was rapidly cleaved to 21612 mot wt fragment and the breakdown product appeared rapidly in the circulation with no lag phase. p961 and metabolite were not detected in rat urine and bile....

  • PDF

Bioequivalence of Cefaclor (250 mg) Capsule (세파클러 250 mg 캅셀의 생물학적 동등성)

  • Yun, MH;Kim, HS;Choi, YP;Kwon, KI
    • Korean Journal of Clinical Pharmacy
    • /
    • v.12 no.2
    • /
    • pp.71-75
    • /
    • 2002
  • This study was carried out to compare the bioavailability of $Ceclex^{(R)}$ (test drug, cefaclor 250 mg/capsule) with that of $Ceclor^{(R)}$ (reference drug) and to estimate the pharmacokinetic parameters of cefaclor in healthy Korean adult. The bioavailability was examined on 20 healthy volunteers who received a single dose (250 mg) of each drug in the fasting state in a randomized balanced 2-way crossover design. After dosing, blood samples were collected for a period of 6hours. Plasma concentrations of cefaclor were determined using HPLC with UV detection. The pharmacokinetic parameters $(AUC_{0-6hr},\;C_{max},\;T_{max},\;AUC_{int},\;K_e,\;t_{1/2},\;Vd)$ F, and CL/F) were calculated with non-compartmental pharmacokinetic analysis. The ANOVA test was utilized for the statistical analysis of the $T_{max},\;log-transformed\;AUC_{0-6hr}\;log-transformed\;C_{max},\;t_{l/2},\;V_d/F$, and CL/F. The ratios of geometric means of AUC0-6hr and $C_{max}$ between test drug and reference drug were $103.2\%\;(6.74\;{\mu}g{\cdot}hr/ml\;vs\;6.53{\pm}g{\cdot}hr/ml)\;and\;100.4\%\;(4.85\;{\mu}g\ml\;vs\;4.82\;{\mu}g/ml)$, respectively. The $T_{max}$ of test drug and reference drug were $0.9\pm0.38\;hr\;and\;0.83\pm0.34$ hrs, respectively. The $90\%$ confidence intervals of mean difference of logarithmic transformed $AUC_{0-6h},\;and\;C_{max}$ were log $0.98{\sim}log$ 1.08 and log $0.88{\sim}log1.15$, respectively. It shows that the bioavailability of test drug is equivalent with that of reference drug. The estimated half-life of this study was longer $(1.21\pm0.27\;hrs\;vs\;0.5-1\;hr)$, the Vd/F was larger $(68.89\pm25.72L$ vs 24.9L), and the CL/F was higher $(38.62\pm7.09\;L/hr$ vs 24.9 L/hr) than the previously reported values.

  • PDF

Endovascular Treatment of Incidentally Found Multiple Aneurysms Originating from a Bronchial Artery: A Case Report (우연히 발견된 하나의 기관지 동맥에서 발생한 다발성 동맥류에 대한 혈관내 치료: 증례 보고)

  • Minhyeok Yoon;Jung Guen Cha;Jongmin Park;Sang Yub Lee;See Hyung Kim;Jihoon Hong;Byunggeon Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1191-1196
    • /
    • 2023
  • Bronchial artery aneurysm (BAA) is a rare disease, and multiple aneurysms of a single bronchial artery are rarer. Regardless of the size of the lesion, it is at risk of rupture and can cause massive hemoptysis or severe pain. We report a rare case of bronchial artery embolization (BAE) of multiple aneurysms of a single bronchial artery. During medical examination, a 64-year-old female was diagnosed with multiple BAAs and endobronchial lesions in the right lower lung on CT 10 years prior to presentation to our hospital. Further evaluation of the lesions was recommended; however, the patient was lost to follow-up. The patient complained of dyspnea and visited our hospital, and the size of the BAA had increased on CT. BAE was done successfully using N-butyl-2-cyanoacrylate and detachable coils. Follow up CT after BAE showed significant decrease in extent of inflammatory lesion in the right lung.

Effects of Operation Parameters on Pollutants Removal in a Lab-Scale Multi-Layered Soil Filtration System (하천 수질정화를 위한 실험실 규모 다단식 토양여과 시스템에서 오염물질 제거에 미치는 운전인자의 영향)

  • Won, Se-Yeon;Ki, Dong-Won;Yoon, Min-Hyeok;Maeng, Sung-Kyu;Ahn, Kyu-Hong;Park, Joon-Hong;Song, Kyung-Guen
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.91-96
    • /
    • 2012
  • In this study we investigated the effects of operational parameters of a multi-layered soil filtration (filter depth, filtration velocity, and continuous/intermittent operation) on removal of pollutants in river water. As filter depth increased removal of all the pollutants (COD, TP, TN, and $NH_4$-N) was increased because the increase in filter depth increased in contact time between media and pollutants. The removal of TP and $NH_4$-N more increased with the increase in filter depth, comparing to the biological COD removal which was performed only in the top layer, since the removal mechanism of TP and $NH_4$-N was physicochemical process occurring throughout the whole layers. However, the reduction in filtration velocity resulted in decrease of removal all the pollutants removal due to shorter retention time. Biological COD removal was more influenced with the reduction in filtration velocity (longer retention time), than the removal of TP and $NH_4$-N. Because biological process was occurred only in the top layer which has relatively shorter retention time, comparing with physicochemical process occurred throughout whole media. Therefore, it is desirable that the operation parameters be controlled toward increasing retention time, in order to achieve efficient pollutants removal. The change in operation mode (continuos vs. intermittent operations) did not provide significant effects on the pollutant treatment efficiency by the multi-layered soil filtration system. Our findings suggest that for stable long-term operation it should be considered keeping conditions for biological activity and accelerating clogging.

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.