• Title/Summary/Keyword: 윤곽오차

Search Result 96, Processing Time 0.023 seconds

Effects of Traverse Speed on Dimensional Error in Abrasive Water-Jet (입자 워터 젯의 이송속도가 공작물의 치수정밀도에 미치는 영향)

  • 곽재섭;하만경
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 2004
  • Abrasive water-jet(AWJ) machining can cut various materials such as metal, glass and plastics. However, the AWJ machining has some troubles including kerf, rounding and side taper. In this study, we experimently investigated the correlation between the traverse speed of the abrasive water-jet and the dimensional error of the workpiece according to the thickness and the types of the material. The specimen was the stainless steel and the mild steel and the predetermined contour cutting was conducted. A comer radius error, an uncut width and a kerf were measured and evaluated.

Method of Shape Error Measurement for the Optimal Blank Design of Shapes with 3D Contour Lines (목표윤곽선이 3 차원 곡선인 형상의 최적블랭크 설계를 위한 형상오차 측정법)

  • Shim, H.B.
    • Transactions of Materials Processing
    • /
    • v.24 no.1
    • /
    • pp.28-36
    • /
    • 2015
  • After a short review of the iterative optimal blank method, a new method of measuring the shape error for stamped parts with 3D contour lines, which is an essential component of the optimal blank design, is proposed. When the contour line of the target shape does not exist in a plane, but exists in 3D space, especially when the shape of the target contour line is very complicated as in the real automotive parts, then the measurement of the shape error is critical. In the current study, a method of shape error measurement based on the minimum distance is suggested as an evolution of the radius vector method. With the proposed method, the optimal blank shapes of real automotive parts were found and compared to the results of the radius vector method. From the current investigation the new method is found to resolve the issues with the radius vector method.

A Dithering Based Technique for Improving Gray Level Reproduction Capability in Dark Areas on Plasma Display Panels (플라즈마 디스플레이의 어두운 영역에서의 계조 표현 향상을 위한 디더링 방법)

  • Park, Seung-Ho;Kim, Chun-U
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Because of the reduced number of displayable gray levels resulting from inverse gamma correction, images on a plasma display panel (PDP) exhibit undesirable false contours in dark areas. An error diffusion method has been applied to remedy this problem. However, it is computationally expensive and requires large memory resources. This paper proposes a computationally efficient dithering based technique to improve the gray level reproduction capability in dark areas. In the proposed method, multiple dithering masks ate utilized in turn to improve the gray level reproduction in dark areas. Also, in order to reduce undesirable regular patterns generated by the dithering method, positions of threshold values within a given dithering mask are changed. Compared to the error diffusion method, the proposed method requires much less computations and memory resources with a comparable gray level reproduction capability.

A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device (전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구)

  • Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.68-75
    • /
    • 2006
  • During cancer therapy by using high energy radiation, it is possible to improve the radiation therapy efficiency by performing a precise radiation therapy after verification of generated setup errors. In this paper, the video based electronic portal imaging device (EPID) which could display the portal image with near real time was developed to verify treatment position errors in radiation therapy instead of an analog typed portal film. This EPID system for applying QA tool of radiation therapy machine was consisted of a metal/fluorescent screen, $45^{\circ}$mirror, camera and image grabber. Radiation field verification has been performed to check quality assurance of the treatment machine itself by using this EPID system. The radiation field error was easily observed by edge detection of irradiated field size on EPID image when $0.6^{\circ}$ shift of collimator angle was generated. So, this implemented EPID system could be used as a radiation QA tool.

Improvement of Mid-Wave Infrared Image Visibility Using Edge Information of KOMPSAT-3A Panchromatic Image (KOMPSAT-3A 전정색 영상의 윤곽 정보를 이용한 중적외선 영상 시인성 개선)

  • Jinmin Lee;Taeheon Kim;Hanul Kim;Hongtak Lee;Youkyung Han
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1283-1297
    • /
    • 2023
  • Mid-wave infrared (MWIR) imagery, due to its ability to capture the temperature of land cover and objects, serves as a crucial data source in various fields including environmental monitoring and defense. The KOMPSAT-3A satellite acquires MWIR imagery with high spatial resolution compared to other satellites. However, the limited spatial resolution of MWIR imagery, in comparison to electro-optical (EO) imagery, constrains the optimal utilization of the KOMPSAT-3A data. This study aims to create a highly visible MWIR fusion image by leveraging the edge information from the KOMPSAT-3A panchromatic (PAN) image. Preprocessing is implemented to mitigate the relative geometric errors between the PAN and MWIR images. Subsequently, we employ a pre-trained pixel difference network (PiDiNet), a deep learning-based edge information extraction technique, to extract the boundaries of objects from the preprocessed PAN images. The MWIR fusion imagery is then generated by emphasizing the brightness value corresponding to the edge information of the PAN image. To evaluate the proposed method, the MWIR fusion images were generated in three different sites. As a result, the boundaries of terrain and objects in the MWIR fusion images were emphasized to provide detailed thermal information of the interest area. Especially, the MWIR fusion image provided the thermal information of objects such as airplanes and ships which are hard to detect in the original MWIR images. This study demonstrated that the proposed method could generate a single image that combines visible details from an EO image and thermal information from an MWIR image, which contributes to increasing the usage of MWIR imagery.

Development of a Verification Tool in Radiation Treatment Setup (방사선치료 시 환자자세 확인을 위한 영상 분석 도구의 개발)

  • 조병철;강세권;한승희;박희철;박석원;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • In 3-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), many studies on reducing setup error have been conducted in order to focus the irradiation on the tumors while sparing normal tissues as much as possible. As one of these efforts, we developed an image enhancement and registration tool for simulators and portal images that analyze setup errors in a quantitative manner. For setup verification, we used simulator (films and EC-L films (Kodak, USA) as portal images. In addition, digital-captured images during simulation, and digitally-reconstructed radiographs (DRR) can be used as reference images in the software, which is coded using IDL5.4 (Research Systems Inc., USA). To improve the poor contrast of portal images, histogram-equalization, and adaptive histogram equalization, CLAHE (contrast limited adaptive histogram equalization) was implemented in the software. For image registration between simulator and portal images, contours drawn on the simulator image were transferred into the portal image, and then aligned onto the same anatomical structures on the portal image. In conclusion, applying CLAHE considerably improved the contrast of portal images and also enabled the analysis of setup errors in a quantitative manner.

  • PDF

A Study on Effective Moving Object Segmentation and Fast Tracking Algorithm (효율적인 이동물체 분할과 고속 추적 알고리즘에 관한 연구)

  • Jo, Yeong-Seok;Lee, Ju-Sin
    • The KIPS Transactions:PartB
    • /
    • v.9B no.3
    • /
    • pp.359-368
    • /
    • 2002
  • In this paper, we propose effective boundary line extraction algorithm for moving objects by matching error image and moving vectors, and fast tracking algorithm for moving object by partial boundary lines. We extracted boundary line for moving object by generating seeds with probability distribution function based on Watershed algorithm, and by extracting boundary line for moving objects through extending seeds, and then by using moving vectors. We processed tracking algorithm for moving object by using a part of boundary lines as features. We set up a part of every-direction boundary line for moving object as the initial feature vectors for moving objects. Then, we tracked moving object within current frames by using feature vector for the previous frames. As the result of the simulation for tracking moving object on the real images, we found that tracking processing of the proposed algorithm was simple due to tracking boundary line only for moving object as a feature, in contrast to the traditional tracking algorithm for active contour line that have varying processing cost with the length of boundary line. The operations was reduced about 39% as contrasted with the full search BMA. Tracking error was less than 4 pixel when the feature vector was $(15\times{5)}$ through the information of every-direction boundary line. The proposed algorithm just needed 200 times of search operation.

Implementation of Motion Detection based on Extracting Reflected Light using 3-Successive Video Frames (3개의 연속된 프레임을 이용한 반사된 빛 영역추출 기반의 동작검출 알고리즘 구현)

  • Kim, Chang Min;Lee, Kyu Woong
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.3
    • /
    • pp.133-138
    • /
    • 2016
  • Motion detection algorithms based on difference image are classified into background subtraction and previous frame subtraction. 1) Background subtraction is a convenient and effective method for detecting foreground objects in a stationary background. However in real world scenarios, especially outdoors, this restriction, (i.e., stationary background) often turns out to be impractical since the background may not be stable. 2) Previous frame subtraction is a simple technique for detecting motion in an image. The difference between two frames depends upon the amount of motion that occurs from one frame to the next. Both these straightforward methods fail when the object moves very "slightly and slowly". In order to efficiently deal with the problem, in this paper we present an algorithm for motion detection that incorporates "reflected light area" and "difference image". This reflected light area is generated during the frame production process. It processes multiplex difference image and AND-arithmetic of bitwise. This process incorporates the accuracy of background subtraction and environmental adaptability of previous frame subtraction and reduces noise generation. Also, the performance of the proposed method is demonstrated by the performance assessment of each method using Gait database sample of CASIA.

Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact (Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가)

  • Lee, Chung-Hwan;Yun, In-Ha;Hong, Dong-Gi;Back, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.85-95
    • /
    • 2010
  • Purpose: The degradation of an image quality and error of the beam dose calculation can be caused because the metal artifact is generated during the CT simulation of head and neck patient. The usability of the gantry tilt scan for reducing the metal artifact tries to be appraised. Materials and Methods: The inferior $20^{\circ}$ gantry tilt scan was made in order to reduce the metal artifact and $0^{\circ}$ reconstruction image was acquired. The AAPM CT performance Phantom was used in order to compare the CT number of the reconstructed image and Original image. the difference of volume was compared by using the acrylic phantom. The homogeneity of the CT number was evaluated the Intensity volume Histogram (IVH) as in order to evaluate an influence by the metal artifact. A dose was evaluated as the Dose Volume Histogram (DVH). Results: in the comparison of the CT number and volume, the difference showed up less than 0.5%. As to the comparison of IVH, in the gantry tilt scan, influence by an artifact was reduced and the homogeneity of the CT number was improved. The comparison of DVH result reduced the mean dose error of the both sides parotid 0.2~6%. Conclusion: In the Head & Neck radiation therapy, It is difficult and to distinguish tumor and normal tissue and the error of dose is generated by the metal artifact. The delineation of the exact organization was possible if the Gantry tilt scan was used. The CT number homogeneity was improved and the error of dose could be reduced. The Gantry tilt scan confirmed in the Head & Neck radiation therapy to be very useful in the exact radiation therapy.

  • PDF

동해지역의 선상중력자료 처리 및 해면고도계자료와의 비교

  • 최광선;원지훈
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.19-19
    • /
    • 2003
  • 본 연구에서는 국립해양조사원의 '해양2000호'를 통해 1996년과 1997년에 측정한 동해 지역의 중력자료에 대한 자료 처리를 하였다. 효과적인 자료처리를 위해 선상중력자료 처리에 필요한 각종 보정 절차와 문제점 등을 알아보았으며, 선상자료와 해면고도계자료의 비교 및 이를 통한 선상자료의 검증을 실시하였다. 선상중력자료는 측정과 처리 과정에 있어 여러 사항을 고려하여야 한다. 즉, 육상중력기점을 이용한 절대중력으로의 환산 문제, 선박 항해 위치의 부정확성에 기인하는 문제 및 중력계의 기계적 특성과 중력 측정이 이루어질 때의 해상 조건에 의한 영향 등으로 선상중력자료에 나타나는 여러 오차를 최소화하여야 한다. 선상중력자료로부터 각종 지구중력장 연구에 필요한 중력이상을 계산하기 위해 선상중력 측정시 기인되는 각종 요인의 오차를 고려한 효과적인 보정이 이루어져야 한다. 즉, 선상중력계의 기계변이 보정, 탐사선에 대한 위치 자료의 획득 및 필터링, 그리고 탐사선의 이동으로 인한 Eotvos 효과의 정확한 계산 및 보정이 필요하고, 선상중력계의 기계적 특성에 의해 나타나는 시간지연에 대한 보정도 필요하다. 또한 이러한 보정을 통해 계산한 중력 이상에서 각 교점의 오차를 보정하는 교정오차 보정도 실시하여야 한다. 특히, 탐사선의 이동으로 인한 지구자전 각속도의 상대적인 증감의 효과로 나타나는 Eotvos 효과의 영향은 선상중력자료의 정확도에 가장 큰 영향을 미친다. 이의 정확한 계산 및 보정을 위해서는 정확한 위치정보가 필요하며 본 연구에서는 이를 위해 GPS 항해정보에 대한 Kalman 필터를 실시하였고, Eotvos 효과에 대해 Savitzky-Golay 필터를 적용하여 최적의 Eotvos 보정을 시도하였다. 본 연구에서 계산된 동해지역의 중력이상에 대한 대력적인 범위는 경도 129° - 133°이고 위도 35° - 38.3° 부근이다. 이 지역에 대한 고도이상은 최소 -42.46 mGal에서 최고 161.13 mGal사이에 분포하며, 고도이상의 평균은 14.450 mGal이다. 또한 Bouguer 이상은 최소 -l5.09 mGal에서 최고 218.61 mGal이고 이의 평균은 82.681 mGal이다. 그리고 동해지역의 선상중력 측정지역에서 선상자료에 의한 중력이상과 Altimeter 자료에 의한 고도이상의 전반적인 윤곽은 비슷하면서도 일부 작은 이상의 차이가 나타났으며, 지형자료와 비교하여 보면 Altimeter에 의한 결과보다 선상측정에 의한 결과가 더욱 잘 일치하고 있어 본 연구에서 계산한 선상자료의 타당성을 알 수 있다. 고도이상의 차이는 최소 -25.94 mGal에서 최대 85.33 mGal의 차이를 보이며 차이의 평균은 3.517 mGal, RMS는 6.774 meal이다. 이는 비교적 큰 차이로 선상측정자료의 중요성과 필요성을 단적으로 나타내고 있다.

  • PDF