• Title/Summary/Keyword: 윤곽선도

Search Result 829, Processing Time 0.028 seconds

Stereoscopic depth of surfaces lying in the same visual direction depends on the visual direction of surface features (표면 요소의 시선방향에 의한 동일시선 상에 놓여있는 표면의 입체시 깊이 변화)

  • Kham Keetaek
    • Korean Journal of Cognitive Science
    • /
    • v.15 no.4
    • /
    • pp.1-14
    • /
    • 2004
  • When two objects are tying in the same visual direction there occurs abrupt depth change between two objects, which is against the assumption of the computational model for stereopsis on the surfaces in a natural scene. For this reason, this stimulus configuration is popularly used in the studies for the effectiveness of the constraints employed in the computational model. Contrary to the results from two nails (or objects) tying in the same visual direction, the two different surfaces from random-dot stereogram (RDS) in the same situation can be seen simultaneously in the different depth. The seemingly contradictory results between two situations my reflect the different strategies imposed by binocular mechanism for each situation during binocular matching process. Otherwise, the surfaces tying in the same visual direction is not equivalent situation to two objects tying in the same visual direction with regards to matching process. In order to examine above possibilities, the stereoscopic depth of the surface was measured after manipulating the visual direction of the surface elements. The visual direction of each dot pair from different surfaces in RDS (in Experiment 1) or the visual direction of line (hawing rectangle with regard to that of the vertical line (in Experiment 2) was manipulated. The stereoscopic depth of the surface was found to be varied depending on visual direction of the surface elements in both RDS and line hawing stimulus. Similar to the results from two nails situation depth of the surface was greatly reduced when each surface element was tying in the same visual direction as that of the other surface element or the other object. These results suggest that binocular mechanism imposes no different strategy in resolving correspondence problem in both two objects and two surfaces situation. And the results were discussed in the context of usefulness of the constraints employed in the computational model for stereopsis.

  • PDF

The analysis of physical features and affective words on facial types of Korean females in twenties (얼굴의 물리적 특징 분석 및 얼굴 관련 감성 어휘 분석 - 20대 한국인 여성 얼굴을 대상으로 -)

  • 박수진;한재현;정찬섭
    • Korean Journal of Cognitive Science
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • This study was performed to analyze the physical attributes of the faces and affective words on the fares. For analyzing physical attributes inside of a face, 36 facial features were selected and almost of them were the lengths or distance values. For analyzing facial contour 14 points were selected and the lengths from nose-end to them were measured. The values of these features except ratio values normalized by facial vortical length or facial horizontal length because the face size of each person is different. The principal component analysis (PCA) was performed and four major factors were extracted: 'facial contour' component, 'vortical length of eye' component, 'facial width' component, 'eyebrow region' component. We supposed the five-dimensional imaginary space of faces using factor scores of PCA, and selected representative faces evenly in this space. On the other hand, the affective words on faces were collected from magazines and through surveys. The factor analysis and multidimensional scaling method were performed and two orthogonal dimensions for the affections on faces were suggested: babyish-mature and sharp-soft.

  • PDF

Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy (폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구)

  • Park, Jae Won;Kang, Min Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • The purpose of this study is to evaluate efficacy and feasibility of adaptive radiotherapy according to tumor volume change (TVC) in early stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-two lesions previously treated with SBRT were selected. SBRT was usually performed with a total dose of 48 Gy or 60 Gy in four fractions with an interval of three to four days between treatments. For evaluation of TVC, gross tumor volume (GTV) was contoured on each cone-beam computed tomography (CBCT) image used for image guidance. Intensity modulated radiotherapy (IMRT) planning was performed in the first CBCT (CBCT1) using a baseline plan. For ART planning (ART), re-optimization was performed at $2^{nd}$, $3^{rd}$, and $4^{th}$ CBCTs (CBCT2, CBCT3, and CBCT4) using the same angle and constraint used for the baseline plan. The ART plan was compared with the non-ART plan, which generated copying of the baseline plan to other CBCTs. Average GTV volume was 10.7 cc. Average TVC was -1.5%, 7.3%, and -25.1% in CBCT2, CBCT3, and CBCT4 and the TVC after CBCT3 was significant (p<0.05). However, the nine lesions were increased GTV in CBCT2. In the ART plan, $V_{20\;Gy}$, $D_{1500\;cc}$, and $D_{1000\;cc}$ of lung were significantly decreased (p<0.05), and $V_{30\;Gy}$ and $V_{32\;Gy}$ of the chest wall were also decreased (p<0.05). While D min of planning target volume (PTV) decreased by 8.3% in the non-ART plan of CBCT2 compared with the baseline plan in lesions with increased tumor size (p=0.021), PTV coverage was not compromised in the ART plan. Based on this result, use of the ART plan may improve target coverage and OAR saving. Thus ART using CBCT should be considered in early stage NSCLC with SBRT.

Study on the Design Ideas and Planning Method of the Gameunsa Temple Architecture in Silla (신라감은사건축의 계획이념과 설계기술 고찰)

  • Lee, Jeongmin
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.238-259
    • /
    • 2021
  • Gameunsa Temple is a Buddhist temple from the mid-Silla period. Construction began during the reign of King Munmu and was completed during the second year of King Sinmun's reign (682). This study is based on the results of excavations at the Gameunsa Temple site, exploring the findings presented in the literature in the field of history. This study also investigates the characteristics of the construction plan of Gameunsa Temple and its correlation with the political, social, and religious environment of the time. The results of the study are as follows: (1) First, it is confirmed that all of the buildings in the central block of Gameunsa Temple, such as the pagoda and corridor, the central gate, and the auditorium, fit within 216 cheoks by 216 cheoks (Goguryeo unit of measurement, estimated dimensions 353.30 mm), in terms of the base structure. This fact is highly significant considering the intent of the King in the mid-Silla period to advocate Confucian political ideals at the Donghaegu sites (Daewangam, Igyeondae Pavilion, and Gameunsa Temple), as confirmed by the relationship between the 'Manpasikjeok legend' and the Confucianism of the etiquette and the music; the relationship between the name of the 'Igyeondae Pavilion' and the 'I Ching'; and the relationship between the 'Taegeuk stones excavated from the Gameunsa Temple site' and the 'I Ching.' Additionally, it may be presumed that the number in the "Qian 216" on the Xici shang of 'I Ching' was used as a basis for determining the size of the central block in the early stages of the design of Gameunsa Temple. The layout of the halls and pagodas of Gameunsa Temple was planned to be within a 216-cheok-by-216-cheok area, from the edge to the center, i.e., on the central axis of the temple, in the following order: the central gate and auditorium, the north-south position of Geumdang Hall, the south corridor, the east-west buildings of the auditorium and the winged corridor, the east-west corridor, and the central position of the east-west stone pagoda. (2) Second, the coexistence of Confucianism and Buddhism in the architecture of Gameunsa Temple is based on the understanding of the Golden Light Sutra, originating from the aspirations of King Munmu to obtain the immeasurable merits (陰陽調和時不越序 日月星宿不失常度 風雨隨時無諸災横) and the light of the Buddha, which is metaphorically represented by the sun and the moon illuminating the whole world of Silla, a new nation with a Confucian political ideology, for a long time by "circumambulating the Buddha (旋繞)". It is also presumed that Gyeongheung, who was appointed by King Munmu to be the Guksa in his will and appointed as the Gukro after the enthronement of King Sinmun, was deeply involved in the conception and realization of the syncretism of Confucianism and Buddhism.

Recovery rate, growth and development of Heterophyopsis continua in experimental chicks (병아리에서 Heterophuopsis continua의 충체 회수율 및 성장 발육)

  • 홍성종;이순형
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.53-62
    • /
    • 1990
  • The growth and developmental pattern of H. continua was observed after experimental infection of their metacercariae to chicks. The recovery rate of worms from the chicks at 1 to 28 days post-infection(PI) was 12.8% in average. The rate remained fairly high for early 4 days of infection but decreased thereafter rapidly till 28 days PI. Most of the nukes, 91.9%, were recovered from the ileum of the chicks. In metacercariae, genital organs such as the ovary, testes, seminal vesicle, seminal receptacle and genital sucker were recognizable. At one day PI Mehlis'gland appeared, and at 2 days follicular vitellaria were observed. At 3 days PI, eggs were formed in the uterine tubule and increased in number as the worm grew old. The worms reached $2,990{\;}{\mu\textrm{m}}$ in length and $525{\;}{\mu\textrm{m}}$ in width at 28 days PI. Genital organs developed rapidly in early stages of infection but slowly thereafter to 28 days Pl, whereas non-genital organs developed steadily through the infection period. It was proved by this experiment that chicks should be a moderately suitable final host of H. continua.

  • PDF

Exploratory Study on the Phenomenon of Technology Transfer in Livestock Industry Based on the Grounded Theory Approach: Backward Linkage Industries in Livestock Industry (근거이론 접근법을 이용한 축산업분야 기술이전현상에 관한 탐색연구: 후방연관산업을 중심으로)

  • Seol, Byung Moon;Park, Jong Bok
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.11 no.1
    • /
    • pp.97-108
    • /
    • 2016
  • The competition between countries became internationalized in the market. However, a situation in which globalization is concerned is important to domestic corporates. Corporate strategy to survive in the domestic market are also juggling the limit of survival. Technology transfer and commercialization at this point has important implications now. The same applies to the national level. Public-to-private technology transfer has been more important, in order to overcome the international competitions. Although various studies have been made to promote technology transfer, in the livestock sector rarely attempted. Taking into account that few previous research and theory development has been achieved, the paper explored the technology transfer phenomenon in the sector employing the grounded theory approach by Strauss & Corbin(1998). Corporates that licensed in technologies through the Foundation of Agri. Tech. Commercialization & Transfer, were targeted as informants or interviewees. Finally, eight informants were selected sequentially utilizing theoretical sampling technique to the saturation point. As the result of open coding and axial coding of the interview data using NVivo10 by QSR International, 77 concepts, 20 sub-categories, and 7 categories were derived while paradigm model was established. Through selective coding, 'the factors affecting technology transfer in livestock sector' was identified as core category. The story line about the core category was developed based on four main categories. Finally, it is expected that the concepts, categories, and the relationship between them can be an important basis for further research.

  • PDF

PCA 알고리즘과 개선된 퍼지 신경망을 이용한 여권 인식 및 얼굴 인증

  • Jung Byung-Hee;Park Choong-Shik;Kim Kwang-Baek
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2006.06a
    • /
    • pp.336-343
    • /
    • 2006
  • 본 논문에서는 여권 영 상에서 PCA 알고리즘을 이용한 얼굴 인증과 개선된 퍼지 신경망을 이용한 여권 코드 인식 방법을 제안한다. 본 논문에서는 여권영상에 대해 소벨 연산자를 이용하여 에지를 추출하고 에지가 추출된 영상을 수평 스미어링하여 여권코드 영역을 추출한다. 추출된 여권 코드 영역의 기울기를 검사하여 기울기 보정을 하고, 여권 코드 영역을 이진화 한다. 이진화된 여권 코드 영역에 대하여 8방향윤곽선 추적 알고리즘을 적용하여 여권 코드를 추출한다. 추출된 여권 코드는 퍼지 신경망을 개선하여 여권 코드 인식에 적용한다. 개선된 퍼지 신경 망은 입력층과 중간층 사이의 학습 구조로는 FCM 클러스터링 알고리즘을 적용하고 중간층과 출력층 사이의 학습은 일반화된 델타학습 방법을 적용한다. 그리고 학습 성능을 개선하기 위하여 중간층과 출력층의 가중치 조정에 적용되는 학습률을 동적으로 조정하기 위해 퍼지 제어 시스템을 적용한다. 제안된 퍼지 신경망은 목표값과 출력값의 차이에 대한 절대값이 ${\epsilon}$ 보다 적거나 같으면 정확으로 분류하고 크면 부정확으로 분류하여 정확의 총 개수를 퍼지 제어 시스템에 적용하여 학습률과 모멘텀을 동적으로 조정한다. 여권의 주어진 규격에 근거하여 사진 영역을 추출하고 추출된 사진 영역에 대하여 YCbCr와 RGB 정보를 이용하여 얼굴영역을 추출한다. 추출된 얼굴 영역을 PCA 알고리즘과 스냅샷(Snap-Shot) 방법을 적용하여 얼굴 영역의 위조를 판별한다. 제안된 방법의 여권 코드 인식과 얼굴 인증의 성능을 평가하기 위하여 실제 여권 영상에 적용한 결과, 기존의 방법보다 여권 코드 인식과 얼굴 인증에 있어서 효율적인 것을 확인하였다.s, whereas AVs provide much better security.크는 기준년도부터 2031년까지 5년 단위로 계획된 장래도로를 반영하여 구축된다. 교통주제도 및 교통분석용 네트워크는 국가교통DB구축사업을 통해 구축된 자료로서 교통체계효율화법 제9조의4에 따라 공공기관이 교통정책 및 계획수립 등에 활용할 수 있도록 제공하고 있다. 건설교통부의 승인절차를 거쳐 제공하며 활용 후에는 갱신자료 및 활용결과를 통보하는 과정을 거치도록 되어있다. 교통주제도는 국가의 교통정책결정과 관련분야의 기초자료로서 다양하게 활용되고 있으며, 특히 ITS 노드/링크 기본지도로 활용되는 등 교통 분야의 중요한 지리정보로서 구축되고 있다..20{\pm}0.37L$, 72시간에 $1.33{\pm}0.33L$로 유의한 차이를 보였으므로(F=6.153, P=0.004), 술 후 폐환기능 회복에 효과가 있다. 4) 실험군과 대조군의 수술 후 노력성 폐활량은 수술 후 72시간에서 실험군이 $1.90{\pm}0.61L$, 대조군이 $1.51{\pm}0.38L$로 유의한 차이를 보였다(t=2.620, P=0.013). 5) 실험군과 대조군의 수술 후 일초 노력성 호기량은 수술 후 24시간에서 $1.33{\pm}0.56L,\;1.00{\ge}0.28L$로 유의한 차이를 보였고(t=2.530, P=0.017), 술 후 72시간에서 $1.72{\pm}0.65L,\;1.33{\pm}0.3L$로 유의한 차이를 보였다(t=2.540, P=0.016). 6) 대상자의 술 후 폐환기능에 영향을 미치는 요인은 성별로 나타났다. 이에 따

  • PDF

Development of Total Body Irradiation Program (전신방사선조사 프로그램 개발)

  • Choi Byung Ock;Jang Ji Sun;Kang Young Nam;Choi Ihl Bohng;Shin Sung Kyun
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.130-137
    • /
    • 2005
  • In total body irradiation (T81) for leukemia, we have a two methode. One is a AP (anterior-posterior) method and the other is a Lateral methode. Our hospital used lateral methode. T81 must consider about body contour, because of homogeneous dose distribution. For compensation about irregular body contour, we use compensator. For T81 treatment, we must be considered, accurate manufacture of compensator and accurate calculation of dose. We developed the automatic program for T81. This program accomplished for compensator design and dose calculation for irregular body. This program was developed for uses to use in a windows environment using the IDL language. In this program, it use energy data for each energy: TMR, output factor, inverse square law, spoiler, field size factor. This program reduces the error to happen due to the manual. As a development of program, we could decrease the time of treatment plan and care the patient accurately.

  • PDF

Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact (Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가)

  • Lee, Chung-Hwan;Yun, In-Ha;Hong, Dong-Gi;Back, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.85-95
    • /
    • 2010
  • Purpose: The degradation of an image quality and error of the beam dose calculation can be caused because the metal artifact is generated during the CT simulation of head and neck patient. The usability of the gantry tilt scan for reducing the metal artifact tries to be appraised. Materials and Methods: The inferior $20^{\circ}$ gantry tilt scan was made in order to reduce the metal artifact and $0^{\circ}$ reconstruction image was acquired. The AAPM CT performance Phantom was used in order to compare the CT number of the reconstructed image and Original image. the difference of volume was compared by using the acrylic phantom. The homogeneity of the CT number was evaluated the Intensity volume Histogram (IVH) as in order to evaluate an influence by the metal artifact. A dose was evaluated as the Dose Volume Histogram (DVH). Results: in the comparison of the CT number and volume, the difference showed up less than 0.5%. As to the comparison of IVH, in the gantry tilt scan, influence by an artifact was reduced and the homogeneity of the CT number was improved. The comparison of DVH result reduced the mean dose error of the both sides parotid 0.2~6%. Conclusion: In the Head & Neck radiation therapy, It is difficult and to distinguish tumor and normal tissue and the error of dose is generated by the metal artifact. The delineation of the exact organization was possible if the Gantry tilt scan was used. The CT number homogeneity was improved and the error of dose could be reduced. The Gantry tilt scan confirmed in the Head & Neck radiation therapy to be very useful in the exact radiation therapy.

  • PDF

Analysis of change of internal organ in the Inter-and Intrafraction using MVCT (MVCT를 이용한 치료 간(Interfraction) 그리고 치료 중(Intrafraction) 내부 장기 변화 분석)

  • Jung, Won Seok;Kim, Ju Ho;Kim, Young Jae;Shin, Ryung Mi;Oh, Jeong Hun;Jeong, Geon A;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.115-126
    • /
    • 2014
  • Purpose : Depending on a variety of therapeutic areas using MVCT(Megavoltage computed tomography) intra-and interfraction is to evaluate changes in patient position. Materials and Methods : In this study, head and neck, thorax, liver, and prostate tumor patients, 48 people with a full course of treatment for patients with various MVCT scan was performed. Average 60 per patient MVCT images were acquired and analyzed. Results : Interfraction error thorax and abdomen, and pelvis in the longitudinal difference was more than 3 mm. Intrafraction to see a change after the end of treatment MVCT taken, and the results confirmed Intrafraction 2 mm in motion around the longitudinal difference. In addition, due to changes in the movement before and after treatment, Inter-and Intrafraction difference was found. Conclusion : In the present study, the Head and Neck, Thorax, liver, prostate cancer in patients with inter-and intrafraction changes and target the appropriate fixtures to complete the outline of the margin would be helpful is considered.