• Title/Summary/Keyword: 육불화황

Search Result 29, Processing Time 0.03 seconds

Molecular Behavior of $SF_6+H_2$ Structure II Hydrates (sII $SF_6+H_2$ 하이드레이트의 분자 거동)

  • Park, Da-Hye;Lee, Bo Ram;Sa, Jeong-Hoon;Sum, Amadeu K.;Lee, Kun-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.122.2-122.2
    • /
    • 2011
  • Sulfur hexafluoride ($SF_6$), one of the most potent greenhouse gases, is known as a hydrate former and has been studied at the high pressure up to 1.3 GPa with gas mixtures and with aqueous surfactant. Since we regard $SF_6$ as a potential promoter molecule that can stabilize hydrate structure more effectively compare to the other promoters, further investigation is required to verify the stabilizing ability of $SF_6$ in the hydrate structure. However, the insoluble nature of $SF_6$ in water or gases hinders fine scale analyses. This work discusses the data obtained by using molecular dynamics simulations of structure II (sII) clathrate hydrates containing $SF_6$ and $H_2$. The simulations were performed using the TIP4P/Ice model for water molecule and a previously reported $SF_6$ molecular model (optimized at the pure $SF_6$ single phase system (Olivet and Vega, 2007)), and a $H_2$ molecular model (adapted from the THF+$H_2$ hydrate system (Alavi et al., 2006)). The simulations are performed to observe the stability of $SF_6$ and $H_2$ in the sII clathrate hydrate system with varying temperature and pressure conditions and occupancies of $SF_6$ and $H_2$, which cannot be easily tuned experimentally. We observe that stability of H2 enclathrated in the hydrate structure more affected by the occupancy of $SF_6$ molecules and temperature than pressure, which ranges from 1 to 100 bar.

  • PDF

Studies on the $N_2/SF_6$ Permeation Behaviors Using the Polyethersulfone Hollow Fiber Membranes (폴리이서설폰 중공사 막을 이용한 $N_2/SF_6$ 투과거동에 관한 연구)

  • Lee, Hyung-Keun;Kim, Dae-Hoon;An, Young-Mo;Jo, Hang-Dae;Park, Jong-Soo
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.244-251
    • /
    • 2009
  • In this research the polyethersulfone hollow fiber membrane was used to separate Sulfur Hexafluoride ($SF_6$) which is the one of the six greenhouse gases from Air ($N_2$). The effects of the non-solvent (Acetone, Ethanol) type, air-gap and post-treatment (surface silicon coating) were investigated by the structure and performance of the membranes. The structure change of the membrane was examined by scanning electron microscope. The single gas permeation using $N_2$, $SF_6$ through the membrane surface coated with silicon showed maximum 7.64 perm-selectivity improved 3.4 times.

Trends and Characteristics in SF6 Emission Reduction Technology of Electrical Equipment (전력설비에서의 SF6 저감기술 동향 및 특성 분석)

  • Kim, Yeah-Won;Kim, Jeong-Man;Park, Sang-Hyuk;Lee, Moon-Gu
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.269-278
    • /
    • 2013
  • Sulfur hexafloride($SF_6$) emission to atmosphere is lower than $CO_2$, but $SF_6$ GWP is 22,800 times lager than $CO_2$. In recent years as restriction of $non-CO_2$ gas has been greatly reinforced, development of environment-friendly technology with $SF_6$ removal is becoming to main issue. This study shows that $SF_6$ used insulator electrical equipment has emission characteristics during the each phase(maintenance, use, diposal), and analyzed $SF_6$ emission reduction technology related phase. The major technology applies maintenance and disposal step is that improvment of gas recovery rate($85{\rightarrow}99%$), manufacturing catalysts, internal inspection of circuit breaker using endoscopy. Using those technolgies can reduce $SF_6$ emission in atmosphere.

Synthesis of the Carbon Nano/micro Coils Applicable to the Catalyst Support to Hold the Tiny Catalyst Grain (매우 작은 크기의 촉매 알갱이를 지지하기 위한 촉매 지지대용 탄소 나노/마이크로 코일의 합성)

  • Park, Chan-Ho;Kim, Sung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.277-284
    • /
    • 2013
  • Carbon coils could be synthesized using $C_2H_2/H_2$ as source gases and $SF_6$ as an incorporated additive gas under thermal chemical vapor deposition system. The Ni layer on the $SiO_2$ substrate was used as a catalyst for the formation of the carbon coils. The characteristics (formation densities, morphologies, and geometries) of the as-grown carbon coils on the substrate with or without the $H_2$ plasma pretreatment process were investigated. By the relatively short time (1 minute) $H_2$ plasma pretreatment on the Ni catalyst layered-substrate prior to the carbon coils synthesis reaction, the dominant formation of the carbon microcoils on the substrate could be achieved. After the relatively long time (30 minutes) $H_2$ plasma pretreatment process, on the other hand, we could obtain the noble-shaped geometrical nanostructures, namely the formation of the numerous carbon nanocoils along the growth of the carbon microcoils. This noble-shaped geometrical nanostructure seemed to play a promising role as the good catalyst support for holding the very tiny Ni catalyst grains.

Study on the Separation of N2/SF6 Mixture Gas Using Polyimide Hollow Fiber Membrane (폴리이미드 중공사 막을 이용한 N2/SF6 혼합기체 분리에 관한 연구)

  • Kim, Dae-Hoon;Kim, Guang-Lim;Jo, Hang-Dae;Park, Jong-Soo;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.660-667
    • /
    • 2010
  • In this research polyimide, Matrimid 5218, hollow fiber membrane was used to recover sulfur hexafluoride($SF_6$) which is one of the six greenhouse gases from $N_2/SF_6$ mixture gas. Fibers were spun from using dry-wet phase inversion method. The module was manufactured by fabricating fibers after surface coating with silicone elastomer. The scanning electron microscopy(SEM) studies showed that the produced fibers typically had an asymmetric structure; a dense top layer supported by a sponge-like substructure. The developed module had a permeance of 0.78-1.36 GPU for $N_2$ with $N_2/SF_6$ selectivity of 2.44-5.08 at various pressure and temperature. For recovery of $SF_6$, a membrane module and 10 vol.% $SF_6$ from $N_2/SF_6$ mixture gas was used. The effects of various operating condition such as pressure, temperature, and retentate side flow rate were tested. When pressure and temperature were increased and retentate flow rate was decreased, the $SF_6$ purity in recovered gas was increased up to 37.5 vol.% with decreasing recovery ratio. When retentate flow rate was increased pressure and temperature was decreased, the $SF_6$ recovery ratio in retentate side was increased up to 89% with decreasing the $SF_6$ purity in retentate side.

Removal of SF6 over Silicon Carbide with Aluminium Oxide by Microwave Irradiation (마이크로웨이브 조사에 따른 산화알루미늄이 함유된 실리콘카바이드의 SF6 제거)

  • Choi, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.4
    • /
    • pp.240-246
    • /
    • 2013
  • $SF_6$ is the most important greenhouse gas with the highest GWP (global warming potential). The $SF_6$ decomposition study was performed with silicon carbide with aluminium oxide by microwave irradiation. DRE (Decomposition and Removal Efficiencie) of $SF_6$ were evaluated by GC-TCD unit using 3,000 ppm $SF_6$ gas. DRE of $SF_6$ was increased by $Al_2O_3$ contents to 10~30 wt%, otherwise $Al_2O_3$ content of 40~50 wt% was decreased. DRE of $SF_6$ up to 99.99% have been achieved in SiC-$Al_2O_3$ (20 wt%) and SiC-$Al_2O_3$ (30 wt%) above $900^{\circ}C$. Also, the DRE of SiC-$Al_2O_3$ (30 wt%) at $700^{\circ}C$ showed 96.72%. In addition to consideration microwave input energy and $Al_2O_3$ content, SiC-$Al_2O_3$ (30 wt%) can be suggested the best material to control $SF_6$. The results of this study suggest it is important to control content of $Al_2O_3$ in SiC for decomposition of $SF_6$ with microwave energy.

A Study on the Improvement Repeatability and Accuracy of the Analysis Method for SF6 of Trace Level (극미량 수준의 SF6 측정법에 따른 재현성 및 정확도 향상에 관한 연구)

  • Yoo, Heejung;Choe, Hongwoo;Lee, Sepyo;Kim, Jongho;Han, Sangok;Ryoo, Sangboom
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Kyoto Protocol, adopted in 1997, set the obligation to reduce $CO_2$, $CH_4$, $N_2O$, HFCs, PFCs, and $SF_6$ in developed countries during 1st promised period. $SF_6$ has been drawing a lot of attention since the Kyoto Protocol because once it is released into the atmosphere, it not only stays in the atmosphere for more than 3,200 years but also emits 22,800 times stronger global warming potential at the same concentrations as $CO_2$ if remains in the atmosphere for 100 years. This study introduces 12 methods for $SF_6$ of measuring trace. $SF_6$ of trace level in the atmosphere correctly, the measurement method was changed and as a result, when the back flush method was applied to the pre-concentration system that used low-temperature concentration and high-temperature desorption system, which used Carboxen-1000 adsorption trap, the effect was the best.

Separation and Recovery of $SF_6$ Gas from $N_2/SF_6$ Gas Mixtures by using a Polymer Hollow Fiber Membranes (고분자 중공사 분리막을 이용한 $N_2/SF_6$ 혼합가스로부터 $SF_6$의 분리 및 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • $SF_6$ (Sulfur hexafluoride) possesses high GWP (Global Warming Potential) as sepcified by the IPCC (Intergonvernmental Panel of Climate Change). Recently, the recovery-separtion of $SF_6$ research area, including permeation properties studies using various membrane's materials and the practical operation of recovery-separtion using membrane of waste $SF_6$ gas is in the initial state. The separation efficiency of a single $SF_6$ and waste $SF_6$ mixture was evaluated using a PSF (polysulfone), PC (tetra-bromo polycarbonate) and PI (polyimide) hollow fiber membranes. According to the results of single gases permeation properties, PI membrane has the highest permselectivity of $N_2$ gas in $N_2/SF_6$ gas. Under the condition of P=0.5 MPa, the highest concentration of recovered $SF_6$ is 95.6 vol % in the separation experiment of $SF_6/N_2$ mixture gas by PC membrane. Under the operation pressure of P=0.3 MPa at a fixed retentate flow rate fixed of 150 cc/min, the maximum recovery efficiency of $SF_6$ is up to 97.8% by PSF membrane. From the results above, it is thought that the separation and recovery technique of $SF_6$ gas using membrane will be used as the representative eco-technology in the $SF_6$ gas treatment in the future.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.