• Title/Summary/Keyword: 유효성인자

Search Result 17, Processing Time 0.019 seconds

Kinetic and Effectiveness Factor for Methanol Steam Reforming over CuO-ZnO-Al2O3 Catalysts (CuO-ZnO-Al2O3 촉매에서의 메탄올 수증기 개질반응에 대한 반응속도와 유효성인자)

  • Lim, Mee-Sook;Suh, Soong-Hyuck
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.3
    • /
    • pp.214-223
    • /
    • 2002
  • Kinetic and effectiveness factors for methanol steam reforming using commercial copper-containing catalysts in a plug flow reactor were investigated over the temperature ranges of $180-250^{\circ}C$ at atmospheric pressure. The selectivity of $CO_2$/$H_2$ was almost 100%, and CO products were not observed under reaction conditions employed in this work. It was indicated that $CO_2$ was directly produced and CO was formed via the reverse water gas shift reaction after methanol steam reforming. The intrinsic kinetics for such reactions were well described by the Langmuir-Hinshelwood model based on the dual-site mechanism. The six parameters in this model, including the activation energy of 103kJ/mol, were estimated from diffusion-free data. The significant effect of internal diffusion was observed for temperature higher than $230^{\circ}C$ or particle sizes larger than 0.36mm. In the diflusion-limited case, this model combined with internal effectiveness factors was also found to be good agreement with experimental data.

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

Study on Development of Patient Effective Dose Calculation Program of Nuclear Medicine Examination (핵의학검사의 환자 유효선량 계산 프로그램 제작에 관한 연구)

  • Seon, Jong-Ryul;Gil, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.657-665
    • /
    • 2017
  • The aim of this study was to develop and distribute a dedicated program that can easily calculate the effective dose of a patient undergoing nuclear medicine examinations, and assist in the study of dose of nuclear medicine examinations and information disclosure. The program produced a database of the effective dose per unit activity administered (mSv/MBq) of the radiopharmaceuticals listed in ICRP 80, 106 Report and the fourth addendum, was designed through Microsoft Visual Basic (In Excel) to take the effect of 5 different (Area, Clark, Solomon(=Fried), Webster, Young) of pediatric dose calculation methods and 7 different body surface area calculation methods. The program calculates the effective dose (mSv) when the age, radionuclide, substance, and amount injected in the human body is inputted. In pediatric cases, when the age is entered, the pediatric method is activated and the pediatric method to be applied can be selected. When the BSA (Body Surface Area) formula is selected in the pediatric calculation method, a selection window for selecting the body surface area calculation method is activated. When the adult dose is input, the infant dose and the effective dose (mSv) are calculated automatically. The patient effective dose calculation program of the nuclear medicine examinations produced in this study is meaningful as a tool for calculating the internal exposure dose of the human body that is most likely to be obtained in nuclear medicine examinations, even though it is not the actual measurement dose. In the future, to increase the utilization of the program, it will be produced as an application that can be used in mobile devices, so that the public can access it easily.

Effects of Game-based Visual Feedback Training on Postural Balance Control (게임기반의 시각 피드백 훈련이 자세균형 조절에 미치는 영향)

  • Yi, Jeong-Won;Yu, Mi;Jeong, Gu-Young;Lee, Nak-Bum;Kwon, Tae-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.25-33
    • /
    • 2012
  • In this study, we analyzed the effects of game-based visual feedback training on postural balance control in young adults. We provided postural balance training for four weeks in fifth minute a day and three days a week using training system of postural balance based forceplate. We evaluated the ability of postural balance using balance SD(Biodex, medicalscience Inc., USA) for the validation of game contents based visual feedback training program. The results showed that postural stability and limits of stability were improved significantly before and after the training(p<0.05). Our study indicates that postural balance training of visual feedback based game could be adapted for improving postural balance. Also, for application of this game-based visual feedback training in older adults, we could develope of various game contents for disease types and conduct quantitative analysis and data collection of postural balance in the aged.

Study on the Smart 1RM System Development and Effect Verification for Health Improvement and Management of National Healthcare (국민 건강관리 및 체력증진을 위한 스마트 1RM 시스템 개발 및 효과 검증에 관한 연구)

  • Woo, Kyung-Min;Shin, Mi-Yeon;Yu, Chang-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, we developed a smart 1RM system for national health management and physical fitness, which enables quantitative 1RM measurement in various types of exercise using digital pulley technology, and to test the effect on training by using it. We developed the smart 1RM system, which is composed of portable muscle strength measuring device, Bluetooth communication based mobile phone data transmission and circuit diagram, and height adjustable system body. We recruited the 30 participants with 20th aged and divided into training and non-performing groups with 15 participants randomly. The participants performed 5 sets of elbow, lumbar, knee extension / flexion 10 times using smart 1RM system and the experimental period was 3 days a week for a total of 8 weeks. The experimental results showed that the maximum strength of the elbow, lumbar, and knee joints was significantly improved before and after maximal muscle strength training in the training group. Oxygen intakes during 1RM exercise mode showed 10.91% than endurance. To verify the validity of the smart 1RM maximal strength data, the reliability was 0.895 (* p <0.00). This study can be applied to the early rehabilitation treatment of the elderly and rehabilitation patients more quantitatively using the national health care.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

A Study on the Efficiency of Zinc Fertilizers Using Zn-65 (Zn-65를 이용(利用)한 아연비료(亞鉛肥料)의 유효도(有效度)에 관(關)한 연구(硏究))

  • U., Zang-Kual
    • Applied Biological Chemistry
    • /
    • v.20 no.2
    • /
    • pp.255-261
    • /
    • 1977
  • Using tracer technique of Zn-65, a pot experiment has been carried out in order to evaluate the efficiency of zinc fertilization on two paddy soils; an acidic from Kimpo and an alkaline from Yeongweol. The sources of zinc were zinc sulfate, zinc carbonate, zinc chloride and zinc oxide. Two rates of zinc were applied to the soils and control treatment was also included for this study. The methods of zinc application were uniform mixing throughout the soil, applying to the soil surface and irrigation water, and root dipping with zinc oxide at transplanting. In general, Yeongweol soil had higher efficiency of zinc fertilizers than Kimpo soil. The results showed that zinc fertilizer application should be required to improve the rice growing conditions in Yeongweol soil especially at early stage of growth after transplanting. As to the application method of zinc fertilizers, mixing treatment appeared to be most superior to any other methods in both soils. In addition, it is found that root dipping in the zinc oxide suspension would be a rather effective method of zinc application. In aspect of fertilizer efficiency there was no superiority or inferiority among the zinc sources used in this experiment.

  • PDF

Consumer Intention to Purchase Domestic/Foreign Brand Jeans;Beliefs, Attitude, and Individual Characteristics. (국내 및 외국 상표 청바지의 구매의도에 따른 평가기준에 대한 신념과 추구이미지 및 의복태도의 차이연구)

  • 고애란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.263-272
    • /
    • 1994
  • The purpose of this study was to identify factors that might distinguish those who have a high level of Intention to purchase each of domestic, foreign designer and national brand jeans from those who have a low intention in terms of evaluative criteria belief, ideal jeans image and clothing altitude. The sample consisted of 198 male and 197 female students from five universities in Seoul. The questionnnaire consisted of 50 seven-point semantic differential scales dealing with evaluative criteria and ideal jeans image, beliefs about and intention to purchase domestic, foreign designer and foreign national brand jeans and 25 Likert type clothing attitude scales. Based on a series of t-tests the results showed that color and design were the most influencing factor among the evaluative criteria belief, regardless of brand type, while durability, accessory, sewing were the least. Sexy image, brand consciousnees and fashion interest were the important factor that distinguish high intention to purchase group fro)m low intention to purchase group.

  • PDF

Cardiopulmonary Response during Mechanical Horseback Riding Exercise in Healthy Adult (건강한 성인에서 기계승마 운동 동안의 심폐 반응)

  • Boo, Seung-Hyun;Noh, Se-Eung;Lee, Eun-Sun;Joo, Min-Cheol
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.243-249
    • /
    • 2016
  • In this paper, we evaluate the effectiveness of mechanical horseback riding exercise training for cardiopulmonary responses in 26 healthy adults (male 14, female 12) and suggest its clinical applicability. Exercise was performed using a mechanical horseback riding machine, JOBA(R) (Panasonic Electric Works, Osaka, Japan) and riding movement speed was increased from level 2 (0.73Hz), to 4 (0.9Hz), to 6 (1.03Hz), to 8 (1.2Hz), to 9 (1.3Hz) and maintained 3minutes in each level. Heart rate, blood pressure, maximum oxygen consumption (VO2max) were measured by respiratory gas analysis system (TruOne 2400, Parvo Medics, USA) and exercise tolerance test system(Q Stress, Cardiac Science, USA). To measure exercise intensity, metabolic equivalent (MET) were measured and percent of Heart rate reserve (%HRR), percent of peak heart rate (%peak HR) and calorie consumption were calculated. The results were analysed by SPSS 18.0. We found that the exercise intensity of mechanical horseback riding exercise using JOBA(R) for 15 minutes is moderate in healthy adult who received pre-training.

Design of The Wearable Device considering ICT-based Silver-care (ICT 기반 실버케어를 고려한 웨어러블 디바이스 설계)

  • Lee, Min-hye;Shin, Seong-yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1347-1354
    • /
    • 2018
  • A bedridden patients, elderly people, and dementia who are subject to special care at a medical institution can not handle the feces themselves and need the help of a guardian or care-giver. In particular, toxic substances are contained in the stools, which can cause eczema, dermatitis and urticaria, so it is important to replace diapers. In this paper, we propose a wearable device design for the detection of excretions in consideration of the various excretion requirements of the elderly. The device is a form in which a module are attached to an adult diaper used in a nursing hospital to detect excreta, and the presence or absence of a wearer can be confirmed by an LED. The measured data is transmitted to the smartphone app in real time via Bluetooth in the module and can be checked for popup notification. The validity of this study was verified by comparing the actual excretion with the data collected through the designed module.