• Title/Summary/Keyword: 유해반응

Search Result 414, Processing Time 0.031 seconds

Effect of Varying Excessive Air Ratios on Nitrogen Oxides and Fuel Consumption Rate during Warm-up in a 2-L Hydrogen Direct Injection Spark Ignition Engine (2 L급 수소 직접분사 전기점화 엔진의 워밍업 시 공기과잉률에 따른 질소산화물 배출 및 연료 소모율에 대한 실험적 분석)

  • Jun Ha;Yongrae Kim;Cheolwoong Park;Young Choi;Jeongwoo Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.52-58
    • /
    • 2023
  • With the increasing awareness of the importance of carbon neutrality in response to global climate change, the utilization of hydrogen as a carbon-free fuel source is also growing. Hydrogen is commonly used in fuel cells (FC), but it can also be utilized in internal combustion engines (ICE) that are based on combustion. Particularly, ICEs that already have established infrastructure for production and supply can greatly contribute to the expansion of hydrogen energy utilization when it becomes difficult to rely solely on fuel cells or expand their infrastructure. However, a disadvantage of utilizing hydrogen through combustion is the potential generation of nitrogen oxides (NOx), which are harmful emissions formed when nitrogen in the air reacts with oxygen at high temperatures. In particular, for the EURO-7 exhaust regulation, which includes cold start operation, efforts to reduce exhaust emissions during the warm-up process are required. Therefore, in this study, the characteristics of nitrogen oxides and fuel consumption were investigated during the warm-up process of cooling water from room temperature to 88℃ using a 2-liter direct injection spark ignition (SI) engine fueled with hydrogen. One advantage of hydrogen, compared to conventional fuels like gasoline, natural gas, and liquefied petroleum gas (LPG), is its wide flammable range, which allows for sparser control of the excessive air ratio. In this study, the excessive air ratio was varied as 1.6/1.8/2.0 during the warm-up process, and the results were analyzed. The experimental results show that as the excessive air ratio becomes sparser during warm-up, the emission of nitrogen oxides per unit time decreases, and the thermal efficiency relatively increases. However, as the time required to reach the final temperature becomes longer, the cumulative emissions and fuel consumption may worsen.

Establishment of Test Conditions and Interlaboratory Comparison Study of Neuro-2a Assay for Saxitoxin Detection (Saxitoxin 검출을 위한 Neuro-2a 시험법 조건 확립 및 실험실 간 변동성 비교 연구)

  • Youngjin Kim;Jooree Seo;Jun Kim;Jeong-In Park;Jong Hee Kim;Hyun Park;Young-Seok Han;Youn-Jung Kim
    • Journal of Marine Life Science
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2024
  • Paralytic shellfish poisoning (PSP) including Saxitoxin (STX) is caused by harmful algae, and poisoning occurs when the contaminated seafood is consumed. The mouse bioassay (MBA), a standard test method for detecting PSP, is being sanctioned in many countries due to its low detection limit and the animal concerns. An alternative to the MBA is the Neuro-2a cell-based assay. This study aimed to establish various test conditions for Neuro-2a assay, including cell density, culture conditions, and STX treatment conditions, to suit the domestic laboratory environment. As a result, the initial cell density was set to 40,000 cells/well and the incubation time to 24 hours. Additionally, the concentration of Ouabain and Veratridine (O/V) was set to 500/50 μM, at which most cells died. In this study, we identified eight concentrations of STX, ranging from 368 to 47,056 fg/μl, which produced an S-shaped dose-response curve when treated with O/V. Through inter-laboratory variability comparison of the Neuro-2a assay, we established five Quality Control Criteria to verify the appropriateness of the experiments and six Data Criteria (Top and Bottom OD, EC50, EC20, Hill slop, and R2 of graph) to determine the reliability of the experimental data. The Neuro-2a assay conducted under the established conditions showed an EC50 value of approximately 1,800~3,500 fg/μl. The intra- & inter-lab variability comparison results showed that the coefficients of variation (CVs) for the Quality Control and Data values ranged from 1.98% to 29.15%, confirming the reproducibility of the experiments. This study presented Quality Control Criteria and Data Criteria to assess the appropriateness of the experiments and confirmed the excellent repeatability and reproducibility of the Neuro-2a assay. To apply the Neuro-2a assay as an alternative method for detecting PSP in domestic seafood, it is essential to establish a toxin extraction method from seafood and toxin quantification methods, and perform correlation analysis with MBA and instrumental analysis methods.

Efficacy and Safety of a Newly Developed Self-Expanding Open-Cell Type Nitinol Stent for Peripheral Arteries: A Preclinical Study in Minipigs (새로 개발된 말초동맥용 자가팽창성 개방형 니티놀 스텐트의 유효성 및 안전성 평가: 미니피그 전임상실험)

  • Min Uk Kim;Jae Hwan Lee;Chang Jin Yoon;Won Seok Choi;Saebeom Hur;Jin Wook Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.899-911
    • /
    • 2020
  • Purpose To evaluate the safety and efficacy of the newly designed open-cell type self-expandable nitinol stent (NiTi-stent) for peripheral arteries. Materials and Methods Twenty-eight limbs of 14 minipigs were randomly assigned to the NiTistent group or conventional nitinol stent group. Stents were symmetrically implanted into the iliac arteries of each animal using carotid artery approach and were observed for 1 month (n = 5) and 6 months (n = 9). The angiographic lumen diameter (ALD), late lumen loss, angiographic stenosis, histomorphometric lumen area, neointimal area, and area stenosis were analyzed and compared between the groups. Results Stent migration, stent fracture, or thrombus formation were not observed in either group. At the 1-month follow-up, the neointimal area (p = 0.008) and area stenosis (p = 0.016) were significantly smaller in the NiTi-stent group than in the control group. At the 6-months followup, the NiTi-stent group showed significantly larger ALD (p = 0.014), less late lumen loss (p = 0.019), less angiographic stenosis (p = 0.014), larger lumen area (p = 0.040), and smaller neointimal area and area stenosis (p = 0.004 and p = 0.014, respectively) compared with the control group. Conclusion The NiTi-stent is as safe and effective as the conventional nitinol stent and induces less neointimal hyperplasia in a minipig iliac artery model.

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.