• Title/Summary/Keyword: 유출계산

Search Result 818, Processing Time 0.026 seconds

Application of multi-dimensional flood damage analysis in urban area (도시지역 침수피해액 산정을 위한 다차원법 적용)

  • Tak, Yong Hun;Kim, Young Do;Kang, Boosik;Park, Mun Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.397-405
    • /
    • 2017
  • In case of inundation in a city where populations and properties are highly concentrated, unlike rural areas it is necessary to apply the method of calculating the damage amount considering the sewage overflow and the corresponding building damage. In this study, Dorim 1 drainage sector has been analyzed with Multi-Dimensional Flood Damage Assessment (MD-FDA) for flood forecast. It is analyzed with past flood history through the SWMM model and calculated the amount of damage with district base data and the result of flow analysis. The result of the SWMM model to predict a range of flood, it was shown that the wide area after 4 hours (at 16:30) by sewer overflow. The building damage was estimated using MD-FDA. As a result, the maximum flood area has shown as $205,955m^2$ (0~0.5 m: $205,190m^2$, over 0.5 m: $865m^2$) and estimated building damage of Dorim 1 drainage sector is approximately 15.5 billion KRW (Korean won) and other contents is 7 billion KRW (Korean won). Also from 0 to 0.5 m depth estimated damage is approximately 22.4 billion KRW (Korean won) and over 0.5 m is 100 million KRW (Korean won). Based on the results of this study, it would be necessary to estimate the amount of sub-divided flood damage in urban areas according to various damage patterns such as flood depth and flood time.

Two-Dimensional Flood Inundation Analysis Resulting from Irrigation Reservoir Failure - Focused on the Real Case with the Minimal Data Set - (농업용 저수지 붕괴에 따른 2차원 홍수범람해석 -계측자료가 부족한 실제사례를 중심으로-)

  • Lee, Jae Young;Kim, Byunghyun;Park, Jun Hyung;Han, Kun Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.231-243
    • /
    • 2016
  • This study presents the applicability of two-dimensional (2D) flood inundation model by applying to real irrigation reservoir failure with limited available data. The study area is Sandae Reservoir placed in Gyeongju and downstream area of it and the reservoir was failured by piping in 2013. The breach hydrograph was estimated from one-dimensional (1D) hydrodynamic model and the discharge was employed for upstream boundary of 2D flood inundation model. Topography of study area was generated by integrating digital contour map and satellite data, and Cartesian grids with 3m resolution to consider geometry of building, road and public stadium were used for 2D flood inundation analysis. The model validation was carried out by comparing predictions with field survey data including reservoir breach outflow, flood extent, flood height and arrival time, and identifying rational ranges with allowed error. In addition, the applicability of 2D model is examined using different simulation conditions involving grid size, building and roughness coefficient. This study is expected to contributed to analysis of irrigation reservoirs were at risk of a failure and setting up Emergency Action Plan (EAP) against irrigation reservoir failure.

Design Method for Cast-in-place Energy Pile Considering Equivalent Heat Exchange Rate (등가열교환율을 적용한 현장타설 에너지파일 설계법)

  • Min, Sunhong;Park, Sangwoo;Jung, Kyoungsik;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1049-1061
    • /
    • 2013
  • In this paper, a relative heat exchange rate is numerically compared for cast-in-place concrete energy piles with different heat exchange pipe configurations, and a new design method for energy piles is proposed. An equivalent heat exchange rate was estimated for the W-type (one series loop), multiple U-type (four parallel loops), and coil-type heat exchanger installed in the same large-diameter drilled shaft. In order to simulate a cooling operation in summer by a CFD analysis, the LWT (leaving water temperature) into a energy pile was fixed at $35^{\circ}C$ and then the EWT (entering water temperature) into a heat pump was monitored. In case of continuously applying the artificial maximum cooling load for 100 hours, all of the three types of heat exchangers show the marginally similar heat exchange rate. However, in case of intermittently applying the cooling load with a cycle of 8 hours operation-16 hours off for 7 consecutive days, the coil type heat exchanger exhibits a heat exchange rate only 86 % of the multiple U-type due to measurable thermal interference between pipe loops in the energy pile. On the other hand, the W-type possesses the similar heat exchange rate to the multiple U-type. The equivalent heat exchange rates for each configuration of heat exchangers obtained from the CFD analysis were adopted for implementing the commercial design program (PILESIM2). Finally, a design method for cast-in-place concrete energy piles is proposed along with a design chart in consideration of typical design factors.

Interaction between Groundwater and Surface Water in Urban Area (도시지역의 지하수와 하천수의 교류량)

  • Bae, Sang-Keun;Lee, Seung-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.919-927
    • /
    • 2008
  • Flow exchanges between stream and groundwater are assessed on urban streams in Daegu, Korea. Two rivers and 25 streams with the total length of 240 km run through the study area. The interaction between surface water and groundwater was estimated using Darcy's method. The study was conducted by dividing the basin into 16 smaller watersheds, and for comparison purposes. Groundwater level, surface water level, hydraulic conductivity, thickness of aquifer, and the distance between the well and the nearest stream were used for quantifying the interaction. To investigations the groundwater interaction in the watersheds, the amount of effluent seepage from groundwater to the stream, the amount of influent seepage from the stream to groundwater, and the amount of annual interaction between surface water and groundwater were computed. The total amount of effluent seepage from the groundwater to stream in the basin was approximately $72{\times}10^6m^3/year$. The total amount of influent seepage from the stream to groundwater was approximately $35{\times}10^6m^3/year$. It appeared that the total amount of annual interaction between surface water and groundwater was approximately $108{\times}10^6m^3/year$ and the total groundwater flow balance was approximately $37{\times}10^6m^3/year$. The annual amount of interaction between the surface water and groundwater was the largest in the Goryung Bridge Basin($29{\times}10^6m^3/year$) and the least in the Dalchang Dam Basin($0.2{\times}10^6m^3/year$). The results show that flow exchanges between stream and groundwater are very active and that there are significant difference among the smaller watersheds. Finally, the results indicate that it is necessary to further investigate to more precisely understand the interaction characteristics between surface water and groundwater in urban areas.

Modification of the Fixed Coefficient Method for the Parameter Estimation of Storage Function Method (저류함수법의 매개변수 추정을 위한 상수고정법의 개선)

  • Chung, Gunhui;Park, Hee-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.1
    • /
    • pp.73-85
    • /
    • 2013
  • The researches on the parameter estimation for storage function method have been conducted for a long time using different methods. However, the determination of the optimal parameters takes a long time and there is a controversy that the proposed optimal parameters do not likely represent the physical characteristics of watershed. In this study, the characteristics of the continuity and storage function equation was analyzed and sensitivities were evaluated. As the result, the only optimal solution is suggested among several local optimums. It is also shown that the lag time is able to be determined using the direct runoff starting time of the watershed. From the sensitivity analysis, it is also proved that the determination of the lag time is very important and the only optimal solution could be found easily after selecting the lag time. Therefore, unlike the traditional optimization method, the proposed method does not take a long time to find the optimal solution which is depending on the characteristics of the rainfall events. The fixed coefficient method which is a method to estimate the optimal parameters of storage function method has been modified using the proposed method. Therefore, the practical efficiency to apply storage function method could be enhanced by applying the proposed method. While the traditional method takes care only the error of the runoff hydrograph, it is very important that the proposed method considers the characteristics of the watershed.

Evaluation of various nutrients removal models by using the data collected from stormwater wetlands and considerations for improving the nitrogen removal (인공습지에서 영양소 제거 설계모델 검토 및 질소제거 개선방안에 대한 고찰)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.90-102
    • /
    • 2017
  • In this study, various types of nutrient models were tested by using two tears's water quality data collected from the stormwater wetland in Korea. Based on results, most important factor influencing nitrogen removal was hydraulic loading rate, which indicates that surface area of wetland is more important than its volumetric capacity, and model proposed by WEF was found to give a least error between measured and calculated values. For the phosphorus, in case assuming a power relationship between rate constant and temperature, the best prediction result were obtained, but temperature was most sensitive parameter affecting phosphorus removal. In addition, denitrification was always a limiting step for the nitrogen removal in this particular wetland mostly due to the lack of carbon source and high dissolved oxygen concentration. In this paper, several alternatives to improve nitrogen removal, including proper arrangement and designation of wetland elements and use of floating plants or synthetic fiber mat to control oxygen level and to capture the algal particles were proposed and discussed.

A Study on the Origin of Anomalously Low Saline Tsushima Current Water Using $^{228}Ra$ ($^{228}Ra$를 이용한 이상 저염 대마난류수의 기원 추적 연구)

  • Lee, Tong-Sup;Kim, Ki-Hyun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.175-182
    • /
    • 1998
  • Recently it is reported that anomalously low saline surface waters (salinity < 32) occurred at the Ulleung Basin in the East Sea-Japan Sea, during early September to November 1996. Apparent source of such a low saline watermass seems remotely linked to the Changjiang Dilute Water (CDW), which expands to the vicinity of Cheju Island during a flood season. Based on the assumption that waters passing through the Western Channel of the Korea Strait are formed by a mixing of Kuroshio Water and CDW, simplified two end-member mixing model using $^{228}Ra/^{226}Ra$ as a conservative tracer is applied to calculate the contribution of each end member for the formation of low saline surface seawater. Model calculations show CDW contributes $58{\pm}3%$ in September 1996 (S=32.17) and $10{\pm}3%$ in February 1997 (S=34.53) in the formation of surface water flowing into the Western Channel of the Korea Strait. Although results arc deduced from a simplified model with limited data, this study demonstrates that Changjiang discharge is clearly traceable to the interior of the East Sea-Japan Sea in fall season. Undergoing Three Valley Dam construction in the Changjiang River would invoke inevitable changes in the nature and discharge of CDW and its impacts on the marine environment might be significant in the northern East China Sea and even in the Ulleng Basin for coming decades.

  • PDF

용담댐 건설로 인한 금강 상류의 하천환경변화 분석 II - 수리변화분석 -

  • 정승권;정동양
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.971-976
    • /
    • 2004
  • 하천유지를 위한 하천내 최소유량의 충족은 사실상 환경문제에 제공되는 것으로서 기본적으로 하천변 수생식물의 생태계 서식처를 유지하거나 복원하기 위해 제공된다. 또한 하천유지유량은 하천의 고유종 동${\cdot}$식물을 보전하고, 아름다운 하천에 대한 심미적 질을 유지하며 여가활동 및 상업적 어획고를 최대로 늘릴 수 있거나 과학적 또는 문화적 관심사의 특성을 보호하는 기능을 위한 목적으로도 제공된다. 그러므로 생태학적인 하천유지유량 차원에서 무엇보다 중요한 것은 충분한 물을 확보하고 쾌적한 하천을 유지할 수 있는 맑은 물을 하천에 흐르도록 하는 것이다. 이와 더불어 하천의 생태학적인 측면에서는 서식지 보호를 고려한 계획이 뒷받침되어야 할 것이다. 기존의 개발은 하천정비, 골재채취, 수중 보와 하구 둑 등 하천시설물 건설, 그리고 댐 및 교량건설 등 인위적인 요인에 의하여 하천환경이 심각하게 변화는 경우가 많다. 특히 댐 건설로 인해 하류지역에 수리학적 변화와 하상 변동 등이 발생하고, 이로 인하여 생태계의 변화를 초래하기도 한다. 따라서 본 연구에서는 금강 최상류에 건설된 용담다목적댐에 의해 인위적으로 하천유입량이 감소하고 이로 인해 발생할 수 있는 수리학적 변화를 모의하여 댐 건설이 금강 상류에 미치는 영향을 분석하고자 한다. 이를 위해 2차원 유한요소모형을 이용하였으며, 댐 건설전 자연유출량 및 댐 건설후 하천유지유량에 의한 하천의 건조면적, 습지면적을 산정하였다. 또한 하천의 한계소류력과 하도를 형성하는 재료에 따라 바닥면 전단응력을 산정하여 그 차(差)를 활용하여 유량에 따른 유사이송현황을 모의하였다. 모의된 결과를 visual하게 표현하고자 GIS 기법을 이용하여 주요구간에 대한 유사이송현황을 도시하였다.유역의 고도차를 이용한 흐름특성 분석을 위해 수치고도자료를 이용하여 유역흐름특성을 분석할 수 있는 TOPAZ(Topographic PArameteri-Zation) 프로그램을 이용하였다. TOPAZ 프로그램을 통해 분석된 각 격자별 분포형 수문 매개변수는 적합한 관계식을 통해 분포형 유출량을 모의하는데 적용된다.다 정확한 유입량 예측이 가능할 것으로 사료된다.이 작은 오차를 발생하였으며, 전체적으로 퍼프 모형이 입자모형보다는 훨씬 적은 수의 계산을 통해서도 작은 오차를 나타낼 수 있다는 것을 알 수 있었다. 그러나 Gaussian 분포를 갖는 퍼프모형은 전단흐름에서의 긴 유선형 농도분포를 모의할 수 없었고, 이에 관한 오차는 전단계수가 증가함에 따라 비선형적으로 증가하였다. 향후, 보다 다양한 흐름영역에서 장${\cdot}$단점 분석 및 오차해석을 수행한 후에 각각의 Lagrangian 모형의 장점만을 갖는 모형결합 방법을 제시할 수 있을 것으로 판단된다.mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술

  • PDF

Urban Drainage Simplification Using Meta-channel Concept (등가하천 개념을 이용한 관망 간략화 기법에 대한 연구)

  • Kim, Hwan-Seok;Pak, Gi-Jung;Yoon, Jae-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1194-1199
    • /
    • 2007
  • 본 연구에서는 도시배수관망의 간략화 모의 시 지선을 단순 생략하는 것이 아니라 2차원 관망을 1차원으로 전환시키는 방법인 등가하천 개념을 도입하여 도시유역의 유출량 산정에 있어서 여러 지선들을 개별적으로 모의하지 않으면서도 실제 존재하는 지선들의 효과를 고려할 수 있는 방법을 개발하고자 하였다. 자연하천에 대해 개발된 등가하천 개념은 최근의 수문모형의 경향인 물리적 분포형 모형의 복잡성을 피하면서 전통적인 개념적 집중형 모형이 가지는 간편성을 살리고 그 것이 가지고 있는 선형가정의 한계를 극복하기 위한 방안으로서 제안된 방법이다. 등가하천 개념을 도입하여 개발된 모형은 종국적으로 강우-유출관계에 있어서 강우의 크기, 선형 및 비선형성, 유역면적 등이 미치는 영향을 분석하기위한 도구로 개발되었으며, 본 연구에서는 출구로부터 동일 거리 s에 위치한 지점에서의 배수관망의 공간적인 분포 및 집중패턴을 파악하는 폭함수(width function, n(s))와 면적함수(area function, M(s))를 이용하여 관망을 간략화 하였다. 등가관의 수리기하조건 결정은 유역이 정상상태에 도달했을 경우에 대해서 이루어지게 되며 정상상태 모의를 통해 개별 관망단면들에 대해 얻어진 유량(Q), 면적(A), 수심(y) 자료간의 상관관계를 유추하여 Q(A), A(y) 함수를 유도하게 되면 종국적으로 관로홍수추적에 이용되는 지배방정식의 매개변수인 파속계수(c) 및 확산계수(D)를 계산할 수 있게 된다. 본 연구에서는 대상 유역으로 군자 배수구역을 선정하여 유역의 특성과 관망 자료를 수집하고 간략화 기법을 적용한 결과를 분석 하였다.다. 21세기 문화산업에서 우리가 판단하게 될 디자인의 가치는 계몽의 원리에 대한 '역사성'과 '현재성'의 변증법에 달려있는 것이며, 새로운 철학, 새로운 문명, 새로운 세계를 열어가는 것이다.r$ (地理志)에는 추현리와 이미 외리를 언급하면서 상주의 자기제작의 위상을 짐작하는 기록이 언급되면서 전국의 상품의 절반을 담당하고 있었음을 알 수 있었다. $\ulcorner$경상도지리지$\lrcorner$(慶尙道地理志)에는 상주가 8곳으로 1/3의 자기 생산을 담당하고 있었다. $\ulcorner$경상도지리지$\lrcorner$(慶尙道地理志)에는 $\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와 동년대에 동일한 목적으로 찬술되었음을 알 수 있다. $\ulcorner$경상도실록지리지$\lrcorner$(慶尙道實錄地理志)에는 $\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와의 비교를 해보면 상 중 하품의 통합 9개소가 삭제되어 있고, $\ulcorner$동국여지승람$\lrcorner$(東國與地勝覽) 에서는 자기소와 도기소의 위치가 완전히 삭제되어 있다. 이러한 현상은 첫째, 15세기

  • PDF

Assessment of Probability Flood according to the Flow Regulation by Multi-purpose Dams in Han-River Basin (한강유역의 다목적댐 운영에 따른 빈도홍수량의 평가)

  • Kim, Nam-Won;Lee, Jeong-Eun
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • The purpose of this study is to evaluate the variation of probability flood according to the flow regulation by multi-purpose dams (Soyang and Chungju) in the Han-river basin, Korea. SWAT-K (Soil and Water Assessment Tool-Korea) was used in order to generate regulated and unregulated daily streamflows upstream of Paldang dam. Simulated flow regulated by the Soyang and Chungju dams was calibrated by comparison with the observed inflow data at Paldang reservoir. Generally the ratio of flood flows to daily streamflows is known to decrease with drainage area in a watershed. Regulated and unregulated flood flows were obtained from the relationship between flood flows and daily streamflows. Extreme Type-I distribution was applied for flood frequency analysis and L-moment method was used for parameter estimation. This is a novel approach capable of understanding the variation in flood frequency with dam operation for the relatively large watershed scale, and this will helps improve the applicability of daily stream flow data for use in flood control as well as in water utilization.