• Title/Summary/Keyword: 유지관리 계측센서

Search Result 107, Processing Time 0.025 seconds

Application for Measurement of Curing Temperature of Concrete in a Construction Site using a Wireless Sensor Network (무선센서네트워크에 의한 콘크리트 양생온도 계측에 관한 현장 적용성 연구)

  • Lee, Sung-Bok;Bae, Kee-Sun;Lee, Do-Heon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.283-291
    • /
    • 2011
  • As the construction industry has recently been transformed by the emergence of ubiquitous and intelligent technology, there have been major changes in the management methods employed. Specifically, next-generation construction management systems have been developed that collect and analyze many pieces of information in real time by using various wireless sensors and networks. The purpose of this study is to understand the current status of Ubiquitous Sensor Networks (USN) in the construction sector, and to gain fundamental data for a system of measuring concrete curing temperature in a construction site that employs a USN. By investigating the application status of USN, it was confirmed that USN has mainly been applied to the maintenance of facilities, safety management, and quality control. In addition, a field experiment in which the curing temperature of concrete was measured using a USN was carried out to evaluate two systems with wireless sensor networks, and the applicability of these systems on site was confirmed. However, it is estimated that the embedded wireless sensor type is affected by metal equipment on site, internal battery of sensor and concrete depth, and studies to provide more stable system by USN are thus required.

Crack Initiation and Temperature Variation Effects on Self-sensing Impedance Responses of FRCCs (FRCCs의 자가센싱 임피던스 응답에 미치는 균열 발생 및 온도 변화 영향성)

  • Kang, Myung-Soo;Kang, Man-Sung;Lee, Han Ju;Yim, Hong Jae;An, Yun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Fiber-Reinforced Cementitious Composites (FRCCs) have electrical conductivity by inserting reinforced conductive fibers into a cementitious matrix. Such characteristic allows us to utilize FRCCs for crack monitoring of a structure by measuring electrical responses without sensor installation. However, the electrical responses are often sensitively altered by temperature variation as well as crack initiation. The temperature variation may disturb crack detection on the measured electrical responses. Moreover, as sensing probes for measuring electrical reponses increase, undesired contact noises are often augmented. In this paper, a self-sensing impedance circuit is specially designed for reducing the number of sensing probes. The crack initiation and temperature variation effects on the self-sensing impedance responses of FRCCs are experimentally investigated using the self-sensing impedance circuit. The experiment results reveal that the electrical impedance response are more sensitively changed due to temperature variation than crack initiation.

An Experimental Study on Crack Detection of RC Structure using Measured Strain (측정변형률을 이용한 RC 구조물의 균열검출에 관한 실험적 연구)

  • Park, Ki-Tae;Park, Hung-Seok;Lee, Kyu-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.193-199
    • /
    • 2002
  • Structral crack of RC structure generally occurs when the tension stress by applied load is larger than tension resistance of concrete, and it means deterioration of structure and the decrease of load resistance. Because structural crack of structure can occur critical damage to structure occasionally, the research on crack detection algorithm of RC structure is needed for assurance of structural safety and effective maintenance of structure. In this paper, we executed the laboratory test on measuring strain of RC beam's tension and compression zone, using strain gauge which is widely used on strain measurement of civil structure. By using measured strain, we analyzed strain change, elastic modulus change, and neutral axis change to detect crack of RC beam. As a result, we proposed the simple and effective crack detection algorithm using trends of neutral axis position change.

A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges (변형률계를 이용한 강재보의 건전도 평가 시스템 개발에 관한 연구)

  • Hahn, Hyun Gyu;Ahn, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.99-109
    • /
    • 2012
  • This study aimed to develop a Structural Health Monitoring System for steel beams in the manner of suggesting and verifying a theoretical formula for displacement estimation using strain gauges, and estimating the loading points and magnitude. According to the results of this study, it was found that when a load of 160kN (56% of the yield load) was applied, the error rate of the deflection obtained with a strain gauge at the point of maximum deflection compared to the deflection measured with a displacement meter was within 2%, and that the estimates of the magnitude and points of load application also showed the error rate of not more than 1%. This suggests that the displacement and load of steel beams can be measured with strain gauges and further, it will enable more cost-effective sensor designing without displacement meter or load cell. The Structural Health Monitoring System program implemented in Lab VIEW gave graded warnings whenever the measured data exceeds the specified range (strength limit state, serviceability limit state, yield strain), and both the serviceability limit state and strength limit state could be simultaneously monitored with strain gauge alone.

Predicting the influent properties in an infiltration trench through deep learning analysis (딥러닝 분석을 통한 침투도랑 내 유입수 성상 예측분석)

  • Jeon, Minsu;Choi, Hyeseon;Geronimo, Franz Kevin;Heidi, Guerra;Jett, Reyes Nash;Kim, Leehyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.363-363
    • /
    • 2022
  • LID 시설에 대한 모니터링은 인력을 활용한 실강우 모니터링을 진행하고 있으나 LID 시설은 소규모 분산형시설로서 인력을 동원한 식생고사, 강우시 모니터링, 현장답사 등 꾸준한 시설확인에 한계가 있으며, LID 시설을 조성한 이후 적정한 유지관리 방법(주기, 빈도, 항목 등)을 인지하지 못하여 막힘현상, 효율저하, 식물고사 등의 문제가 발생한다. 따라서 본연구에서는 딥러닝 분석을 활용하여 강우시 강우모니터링 자료와 LID 시설 내 센서를 통해 측정된 자료를 통해 침투도랑 내 유입수 성상에 대한 예측분석을 수행하였다. 심지 내 LID 시설에 유입되는 오염물질을 예측을 위한 딥러닝 분석을 위해 과거 실강우시 모니터링 자료(TSS, COD, TN, TP)와 대기센서(대기습도, 대기온도, 강수량, 미세먼지) 데이터를 활용하여 딥러닝 모델에 대한 적용가능성 평가를 수행하였다. 측정항목에 대한 상관성 분석을 수행하였으며, 딥러닝 모델은 Tenser Flow를 이용하여 DNN(Deep Neural Network)모델을 활용하여 분석하였다. DNN 모델에 대한 MSE값은 0.31로 분석되었으며, TSS에 대한 평균 50.6mg/L로 분석되었으며, COD 평균 98.7 mg/L로 나타났다. TN의 평균 2.21 mg/L로 분석되었으며, TP 평균 0.67 mg/L로 나타났다. 상관계수분석결과 TSS는 0.53로 분석되었으며, TN과 TP의 상관계수는 0.10, 0.56으로 나타났다. COD의 상관계수는 0.63으로 TSS와 COD, TP에 대한 예측이 된 것으로 분석되었다. 딥러닝을 통한 LID 시설 내 농도변화 예측시 강우시 센서데이터 값은 조밀해야하며 오염물질 농도와 상관성이 높은 항목들에 대해 계측과 실강우 모니터링 자료를 축적하여 미래에 대한 활용성을 높여야 한다.

  • PDF

Evaluation of Relative Corrosion Rate depending on Local Location and Installation of Structural Member in Steel Water Gate (강재 수문의 부재 위치 및 설치 방향에 따른 상대 부식속도 평가)

  • Ha, Min-Gyun;Jeong, Young Soo;Park, Seung hun;Ahn, Jin-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.16-24
    • /
    • 2019
  • The corrosion amounts of steel structures can be different depending on their installation condition and height. Thus, their corrosion maintenance should be considered depending on installation conditions of local structural members. In this study, an atmospheric exposure test was conducted to evaluate the corrosion amount and the corrosion rate depending on the installation condition and height of a steel water gate using monitoring steel plates and corrosion environment measuring sensors. The mean corrosion depth was evaluated using the weight loss method and the galvanic corrosion current was measured by corrosion environment measuring sensors. Local corrosion rate of local structural member in steel water gate was estimated using measured mean corrosion depths and galvanic corrosion currents. From this measurement results, the corrosion damage in horizontal member of the cross beam was highly evaluated than those of other structural member as skin plate, etc. The relative difference in the corrosion rate of a local structural member could be highly affected by local corrosion environments of steel water gate members. Therefore, an appropriate maintenance method should be considered for local corrosion damages of local structural members determined by local corrosion environments of a steel water gate.

Study of Confidence Ranges for Field Phase Difference Measurement Data Collected using Geophones (지오폰을 활용한 현장 위상각차 계측 데이터 신뢰 구간에 관한 기초 연구)

  • Kim, Gunwoong
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.3
    • /
    • pp.41-54
    • /
    • 2024
  • Regular monitoring plays a crucial role in ensuring the safety of geotechnical structures. Currently, nondestructive methods are employed to monitor such structures to minimize the impact, e.g., sensor-based accelerometers, displacement meters, image-based lasers, and drone imaging. These technologies can observe surface changes; however, they frequently suffer difficulties in terms of identifying changes in internal properties. To monitor changes in internal properties, in situ geotechnical investigations can be employed. A nondestructive test that can be used for this purpose is the spectral analysis of surface wave (SASW) test using geophones. The SASW test is a nondestructive method; however, due to the time required for data interpretation and the difficulty in analyzing the data, it is challenging to use the SASW test for monitoring applications that require frequent observations. However, it is possible to apply the first-step analysis, which yields the dispersion curve, for monitoring rather than the complete SASW analysis, which yields the shear wave velocity. Thus, this paper presents a fundamental study on the phase difference that derives the dispersion curve to utilize the SASW test for monitoring. The reliability of each phase difference interval is examined to determine the boundary to the subjected monitor. The study used phase difference data obtained using a geophone from a single-layered, homogeneous ground site to evaluate reliable boundaries. The findings of this study are expected to improve the utility of monitoring by identifying the ideal boundary for phase difference data.

Relative Corrosion Environment Conditions of Steel Box Members Examined by Corrosion Current Measurement (부식전류 평가를 통한 강박스 부재의 상대적 부식환경 평가)

  • Jin, Yong-Hee;Ha, Min-Gyun;Jeong, Young-Soo;Ahn, Jin-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.171-179
    • /
    • 2020
  • In this study, a local corrosion environment monitoring was conducted using steel box specimen fabricated to be the same as actual steel bridge members. The steel box specimen that obtained the same corrosion environment as a steel bridge was classified into the upper plate, bottom plate and web plate. Atmospheric corrosion monitoring sensors(ACM sensors) were installed in each corrosion monitoring member of a steel box specimen to measure the corrosion current and examine time of wetness for each monitoring member. The time of wetness and accumulated corrosion current of each monitoring member were calculated from the measured corrosion current using ACM sensors. The corrosion environment that appeared for each of the steel box members was evaluated from monitoring corrosion environment data as the corrosion current, time of wetness, mean corrosion depth of each monitoring member. Additionally, the atmospheric corrosion environment monitoring was also conducted to compare with the local corrosion environment of steel box members. From these local corrosion environment monitoring for the steel box specimen, the relationship between the relative corrosion environment and mean corrosion depth of each steel box member was examined.

Comparative Study on Feature Extraction Schemes for Feature-based Structural Displacement Measurement (특징점 추출 기법에 따른 구조물 동적 변위 측정 성능에 관한 연구)

  • Junho Gong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.74-82
    • /
    • 2024
  • In this study, feature point detection and displacement measurement performance depending on feature extraction algorithms were compared and analyzed according to environmental changes and target types in the feature point-based displacement measurement algorithm. A three-story frame structure was designed for performance evaluation, and the displacement response of the structure was digitized into FHD (1920×1080) resolution. For performance analysis, the initial measurement distance was set to 10m, and increased up to 40m with an increment of 10m. During the experiments, illuminance was fixed to 450lux or 120lux. The artificial and natural targets mounted on the structure were set as regions of interest and used for feature point detection. Various feature detection algorithms were implemented for performance comparisons. As a result of the feature point detection performance analysis, the Shi-Tomasi corner and KAZE algorithm were found that they were robust to the target type, illuminance change, and increase in measurement distance. The displacement measurement accuracy using those two algorithms was also the highest. However, when using natural targets, the displacement measurement accuracy is lower than that of artificial targets. This indicated the limitation in extracting feature points as the resolution of the natural target decreased as the measurement distance increased.

Monitoring of the Natural Terrain Behavior Using the Terrestrial LiDAR (지상라이다 자료를 이용한 자연사면의 변위 모니터링)

  • Park, Jae Kook;Lee, Sang Yun;Yang, In Tae;Kim, Dong Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2D
    • /
    • pp.191-198
    • /
    • 2010
  • The displacement of slope is a key factor in predicting the risk of a landslide. Therefore, the slope displacement should be continuously observed with high accuracy. Recently, high-tech equipment such as optical fiber sensor, GPS, total station and measuring instrument have been used. However, such equipment is poorly used in fields due to economics, environment, convenience and management. Because of this, development of substantial observational techniques for varied slope observation and field applications is needed. This study analyzed the possibility of terrestrial LiDAR for slope monitoring and suggested it as information-obtaining technique for slope investigation and management. For that, this study evaluated the monitoring accuracy of terrestrial LiDAR and performed GRID analysis to read the displacement area with the naked eye. In addition, it suggested a methodology for slope monitoring.