• Title/Summary/Keyword: 유전체 필름

Search Result 33, Processing Time 0.038 seconds

Permittivity Measurement of Thin Film Using a Waveguide-type Resonator with a Slot (슬랏을 갖는 도파관형 공진기를 이용한 박막 필름의 유전율 측정)

  • Cho, Chihyun;Kang, Jin-Seob;Kim, Jeng-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.214-217
    • /
    • 2013
  • In this paper, a waveguide-type resonator with a slot is proposed to measure permittivity of thin film from resonant frequency shifting by an attached MUT(Material Under Test). The MUT on the slot shifts resonant frequency by perturbation of electromagnetic field. Amount of shifting resonance frequency is dependent on the permittivity of MUT, and that relation is obtained from numerical simulation. The measured relative permittivity of a thin film with thickness of $65{\mu}m$ is 3.3492 with standard error of ${\pm}0.0605$ in the frequency range of 2 GHz to 3 GHz. Also the proposed method is compared with other measuring methods such as dielectric resonator and waveguide probe systems.

Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

Self-assembled Nanostructures for Broadband Light Absorption Enhancement in Silicon Absorber

  • Gang, Gu-Min;Kim, Gyeong-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.134.1-134.1
    • /
    • 2014
  • 콜로이달 리소그래피는 나노미터 크기의 나노구를 자가조립에 의해 정렬시킴으로써, 파장이하 크기의 주기 구조를 저비용으로 쉽게 구현할 수 있는 패터닝 기법이다. 콜로이달 리소그래피나 소프트 리소그래피와 같이 대면적 패터닝이 가능한 공정을 태양전지를 위한 반사방지 및 광 포획 증대 구조에 적용함으로써, 기존 성능을 크게 향상시켰다. 본 연구에서는, 유한차분 시간영역 수치해석법을 이용하여 반사 방지 및 광 포획 증대 구조에 대한 이론적 검증 및 설계를 진행하였고, 콜로이달 리소그래피 및 반도체 공정을 통해 샘플을 제작하였으며, 제작된 샘플의 성능을 적분구를 겸비한 자외선 가시광 근적외선 영역 분광기를 통해 평가하였다. 반사방지 나노섬을 겸비한 나노 원뿔대 언덕형 굴절률 소자를 구현함으로써, 300나노미터 이하의 구조체를 사용하지 않고도 근자외선 영역을 포함하는 태양광 에너지의 손실을 최소화할 수 있는 광대역 방사방지 구조체를 제시하였다. 나노 원뿔대가 격자상수 이상의 파장에 대한 언덕형 굴절률을 제공하고, 4분의 1파장 나노섬 반사방지막이 격자 상수 이하의 근자외선 태양광을 추가적으로 흡수하여, 근자외선 영역에서의 평균 반사율을 3.8% 수준으로 달성 할 수 있었다. 또한, 낮은 양호계수를 갖는 속삭임 회랑 공진기 어레이를 이용하여, 박막 태양전지에 적합한 유전체 기반 광포획 증대 나노구조를 제시하였다. 나노반구, 나노고깔, 나노구, 함몰형 나노구 어레이 형태를 가지며, 500nm의 주기를 갖는 유전체 표면 텍스쳐드 구조를 초박형 비정질 실리콘 필름(100nm) 위에 제작하여 광대역 광 포획 증대 효과를 실험적으로 평가하였다. 구조들 중 함몰형 나노구 어레이가 결합된 비정질 실리콘 박막이 가장 높은 성능을 보였으며, 구조가 없는 경우 대비 약 67.6%의 가중 흡수율 증가를 나타내었다. 특히, 함몰형 나노구 어레이 구조 중 폴리메틸메타아크릴레이트로 제작된 평판형 함몰층은 나노구 비정질 박막 실리콘 사이의 접착력 및 기계적 강성을 향상시켰을 뿐 아니라, 함몰층 내부로 회절되고 산란된 빛들이 도파모드 효과에 의해 부가적인 광 포획 증대를 가져옴으로써, 가장 높은 광 포획 효과를 얻을 수 있었다. 유전체 기반 나노 구조들은 간단하고 저비용이며, 대면적으로 쉽게 제작할 수 있는 자가 조립 기반 콜로이달 리소그래피 및 소프트 리소그래피 기술을 이용하여 제작되었다.

  • PDF

대기압 유전체 배리어 방전을 이용한 폴리머 박막의 증착과 특성 분석에 대한 연구

  • Kim, Gi-Taek;Suzaki, Yoshifumi;Kim, Yun-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.38.2-38.2
    • /
    • 2011
  • 폴리머 박막은 그 고유한 특성으로 인해 여러 산업적으로 널리 사용되고 있는 재료이다 예로 의약품이나 식품 포장지의 배리어, 전자부품의 절연체, 반도체 공정에서의 사용, 혹은 부식방지를 위해 사용 되어지기도 한다. 이 폴리머 박막을 증착 하기 위한 방법으로 이전부터 CVD (Chemical Vapor Deposition) 방법이 많이 사용되었고 지금까지도 가장 많이 사용되는 방법이다. CVD를 사용하여 $SiO_2$-like 필름의 증착은 전구체(precursor)로 Silane ($SiH_4$)을 사용하였으며, 플라즈마 발생 소스(source)로 열 혹은 전기장 등을 사용 하며 공정 시 압력 또한 대부분 저압 하에서 실시 하였다. 이와 같은 이전 CVD 방법의 문제는 사용되는 Silane 자체가 인체에 해로울 정도로 독성이 있으며 폭발성도 같이 가지고 있어 작업환경의 위험성이 높으며 열을 사용한 CVD의 경우 높은 공정 온도로 인해 증착 할 수 있는 대상이 제한 되어 지며 높은 열의 발생을 위해 많은 에너지의 소비가 필요하다. 저압 플라즈마를 사용한 CVD 는 공정상 높은 열의 발생이 일어나지 않아 기판 운용상 문제가 되지 않지만 저압 환경에서 해당 공정이 이루어기 때문에 인해 필수적으로 고가의 진공 챔버가 필수적이며 저압을 유지할 고가의 진공 펌프나 추가 장비들이 필요하게 된다, 또한 챔버 내에서 이루어지는 공정으로 인해 공정의 연속성이 떨어져 시잔비용 또한 많이 잡아 먹는다. 이러한 열 혹은 저압 플라즈마등을 사용한 공정의 단점을 해결하기 위해 여러 연구자들이 다양한 방법을 통해 연구를 하였다. 대기압 유전체 배리어 방전(AP-DBD: Atmospheric Pressure-Dielectric Barrier Discharge)을 사용한 폴리머 박막의 증착은 이전 전통적인 방법에 비해 낮은 장비 가격과 낮은 공정 온도 그리고 연속적인 공정 등의 장점이 있는 폴리머 박막 증착 방법 이다. 대기압 유전체 배리어 방전 공정 변수로 공급 전압 및 주파수 그리고 공급 전압의 영향, 전구체를 유전체 배리어 방전 전극으로 이동 시키기 위해 사용된 캐리어 가스의 종류 및 유량, 화학양론적 계수를 맞추기 위해 같이 포함되는 산소 가스의 유량, DBD 전극의 형태에 따른 증착 박막의 균일성 등 이 존재하며 이런 많은 변수 들에 대한 연구가 진행 되었지만 아직 이 대기압 DBD를 이용한 폴리머 박막의 증착에 대한 명확한 이해는 아직 완전 하다 할 수 없다. 본 연구에서는 이러한 대기압 DBD를 이용하여 폴리머 박막의 증착시 영향을 미치는 많은 공정 변수 등이 박막생성에 미치는 영향과 증착된 박막의 성질에 대한 연구를 진행 하였다.

  • PDF

Synthesis and Analysis of Multi-functional Urethane Acrylate Monomer, and its Application as Curing Agent for Poly(phenylene ether)-based Substrate Material (다관능 우레탄 아크릴레이트 단량체의 합성과 분석, 및 폴리페닐렌에테르 기판소재용 경화성분으로의 적용)

  • Kim, Dong-Kook;Park, Seong-Dae;Oh, Jin-Woo;Kyoung, Jin-Bum
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.413-419
    • /
    • 2012
  • Multi-functional urethane acrylate monomers as the curing agent of poly(phenylene ether) (PPE) were synthesized and then the urethane bond formation was checked by FTIR spectrometry and NMR analysis. The synthesized monomers were mixed with PPE and fabricated to dielectric substrates. After forming PPE/monomer composite sheets by a film coater, several sheets were laminated to a test substrate in a vacuum laminator and then its properties depending on the type and the amount of monomers, such as dielectric constant, dielectric loss, and peel strength, were measured. Between the two different hydroxyl acrylates, when the monomer synthesized with 2-hydroxy-3-phenoxypropyl acrylate containing a phenyl group was used as a curing agent, a smaller dielectric loss was obtained and the dielectric constant and loss decreased with a decrease in the amount of the monomer. The peel strength values of the test substrates, however, did not show any specific difference between the cases of two synthesized monomers. As a result, it was obtained the polymer substrate for high frequency application having peel strength of about 10 N, low dielectric constant of 2.54, and low dielectric loss of 0.0027 at 1 GHz.

XPS Analysis of PVDF Film Treated by Corona Discharge in Ethyl Methacrylate Vapor Atmosphere (에틸메타크릴레이트 증기 분위기에서 코로나 방전 처리한 PVDF 필름의 XPS 분석)

  • Moon, HuiKwon;Seomoon, Kyu
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.627-632
    • /
    • 2016
  • Ethyl methacrylate (EMA) monomer coupling onto the polyvinylidene fluoride (PVDF) film surface was attempted to enhance the interfacial adhesive force between PVDF-polyvinyl chloride (PVC) bilayer films via dielectric barrier corona discharge. The interfacial forces were quite enhanced when PVDF films were treated by corona discharge in an EMA 1% atmosphere. The contact angle of PVDF films decreased due to corona treatment. X-ray photoelectron spectroscopy (XPS) analysis showed that the carbon and oxygen content of the PVDF film surface increased with corona discharge while the fluoride content decreased. The curve fitting of XPS $C_{1s}$ peaks revealed that the non-polar C-C bonded carbon and oxygen-bonded carbon increased gradually with corona treatment, while the fluorine-bonded carbon decreased.

Ceramic capacitor module for hybrid-electric vehicles using embedded capacitor (임베디드 커패시터를 이용한 하이브리드 자동차 커패시터 모듈 특성 연구)

  • Yoon, Jung-Rag;Moon, Bong-Haw;Lee, Keong-Min;Han, Jeoung-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.18-18
    • /
    • 2009
  • 본 논문은 X8R 온도 특성을 가지는 유전체 원료를 이용하여 고용량이면서 고압화가 가능한 적층 칩 캐패시터를 제작하였다. 대형 고압용 적층 칩 캐패시터를 위한 내부 전극 설계 및 외부 전극 형성 방법에 대한 연구도 함께 진행하였다. 적층 칩 캐패시터를 하이브리드 자동차 및 산업용 인버터의 DC-Link으로 사용하기 적합한 모듈을 제작하였으며 모듈 설계시 고유전율의 에폭시-세라믹 필름을 하였다. 본 모듈을 평가한 결과 기존 캐패시터 모듈에 비하여 2/3 크기의 소형화를 얻을 수 있었으며 ripple 전류 및 발열 특성이 매우 우수함을 확인하였다.

  • PDF

Dielectric Characteristics of Composite dielectric Film for Pulsed Power Capacitors (커패시터용 복합유전체필름의 유전특성 분석)

  • Park, J.D.;Kwak, H.R.;Park, H.Y.;Jung, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1661-1663
    • /
    • 2001
  • This paper describes the dielectric characteristics of composite dielectric film for pulsed power capacitors. The relative electric permittivity(${\varepsilon}'$) and the dielectric dissipation factor(tan$\delta$) were measured for polypropylene (PP) membranes, kraft paper for capacitors(CP) and composite dielectric films(PP+CP), respectively, in a frequency range of $1{\sim}10^4$[Hz], and in temperatures ranging from -50[$^{\circ}C$] to 110[$^{\circ}C$]. As a result, the variation of the electric permittivity was observed similarly for PP and CP. Dielectric dispersion was observed in frequency domain in PP, CP and composite dielectric films.

  • PDF

Multi Frequency Thin Film Loop Antenna for Multi-media Devices (멀티미디어단말기용 박막형 다중주파수 안테나)

  • Shin, Cheon-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1288-1296
    • /
    • 2009
  • This paper is for multi-frequency thin film loop antenna used on smart phone, PMP and PDA like as a multi-media devices. We developed a loop pattern folding methods to reduce a thin film antenna dimension using that mutual coupling folding loop occurs the higher frequency resonation. To reduce the thin film size for loop antenna, we fold the loop pattern repeatedly control the coupling coefficient than generate a not only higher mode resonation but also basic resonation from loop pattern. To realization the thin film folded loop antenna, we used a $30mm{\times}9mm$ PI film the thickness is 20um so that we realize the CDMA850, GPS, DCS, PCS, WCDMA antenna simultaneously and it's radiation efficiency is over 50% and gain is 0dBi.

  • PDF

Complete genome sequence of Bacillus licheniformis strain 0DA23-1, a potential starter culture candidate for soybean fermentation (콩발효 종균후보 Bacillus licheniformis 0DA23-1의 유전체 염기서열)

  • Jeong, Do-Won;Lee, Byunghoon;Heo, Sojeong;Jang, Mihyun;Lee, Jong-Hoon
    • Korean Journal of Microbiology
    • /
    • v.54 no.4
    • /
    • pp.453-455
    • /
    • 2018
  • Bacillus licheniformis strain 0DA23-1, a potential fermentation starter candidate, was isolated from doenjang, a Korean high-salt-fermented soybean food. Strain 0DA23-1 contains a single circular 4,405,373-bp chromosome with a G + C content of 45.96%. The complete genome of strain 0DA23-1 does not include any of the virulence factors found in the well-known pathogens Bacillus cereus and Staphylococcus aureus. Additionally, no genes associated with resistance to eight antibiotics (chloramphenicol, clindamycin, erythromycin, gentamicin, kanamycin, streptomycin, tetracycline, and vancomycin), hemolysis, or biofilm formation were identified.