• Title/Summary/Keyword: 유압브레이크시스템

Search Result 31, Processing Time 0.025 seconds

Friction Torque Analysis of a Hydraulic Motor-Load System using Proportional Control Valve (비례제어밸브를 이용한 유압모터 부하계의 마찰토크 해석)

  • Yu, Hwan-Shin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.760-766
    • /
    • 2010
  • In this paper, The static friction torque and viscous friction torque including hydraulic motor-load system driven by hydraulic proportional control valve analysis. The basic experimental was performed toward characteristic in pressure and flow rate in hydraulic system energy. The variable of friction torque was experiment on brake pressure variable using pneumatic brake system. The analysis of nonlinear friction and linear friction was perform ed toward friction characteristic of hydraulic system.

차량 EMB 시스템의 고장 검출 및 대처 방안 설계

  • Geum, Dae-Hyeon;Ban, Dong-Hun;Gwon, Su-Hyeon;Jin, Seong-Ho;Lee, Seong-Hun
    • Information and Communications Magazine
    • /
    • v.34 no.5
    • /
    • pp.19-26
    • /
    • 2017
  • Electromechanical Brake(EMB)시스템은 유압 대신 전동식 액츄에이터를 이용하여 제동력을 발생시키는 브레이크 장치인 Brake-by-Wire(BBW) 시스템의 구성요소 이다. EMB 시스템은 기존 유압식 브레이크 시스템과 비교하여 친환경적이며, 설계의 자유도가 높고, 제동 응답성 및 제어 성능이 뛰어난 장점을 가진다. 하지만 전자 전기적으로 시스템 구성이 복잡해 짐에 따라 고장에 대한 안정성 부문이 설계시 충분히 고려되어야 한다. 본 논문에서는 차량 EMB 시스템 설계시 신뢰성을 향상을 위해 고려해야 설계 방안에 대해서 기술한다. 크게 시스템, 센서, 모터 분야에 대해 고장 요소 및 대처 방안 설계에 대해 개괄적으로 소개한다.

On the Pressurization Characteristics of Small Piezoelectric Hydraulic Pump for Brake System (브레이크용 소형 압전유압펌프 가압 동특성 해석)

  • Jeong, Min-Ji;Hwang, Jai-Hyuk;Bae, Jae-Sung;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.11
    • /
    • pp.963-970
    • /
    • 2015
  • In this study, the pressurization characteristics of the small piezoelectric hydraulic pump for a brake system has been analyzed through modeling the full hydraulic pump components; the pump chamber, check valve, pump load, pump drive controller etc. To analyze the pressurization characteristics, the process of charging pressure in the chamber with stacked-layer piezoelectric actuator were firstly modeled. Secondly, the flow coefficient of the check valve in terms of valve opening has been calculated after computational fluid dynamics analysis, such as the pressure distribution around check valve and the flow rate, was conducted. Also the pump driving controller, which controls the input voltage to the actuator, was designed to make the load pressure follow the input pressure command. The simulation results find that it takes about 0.03ms to reach the operating load pressure required for the braking system. The simulation result was also verified through comparison to the result of the pump performance test.

Performance Analysis and Test of the Small Piezoelectric-Hydraulic Pump Brake System (소형 압전유압펌프 브레이크 시스템의 성능해석 및 실험)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Nguyen, Anh Phuc;Bae, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.49-56
    • /
    • 2018
  • In this paper, the performance analysis and the experiment of the brake system using the small piezoelectric-hydraulic pump were performed. Initially, the 3-D modeling of the brake load components was performed for the construction of the brake system. Subsequently, modeling using the commercial program AMESim was performed. A floating caliper model was used as a load for modeling the brake system. Through the AMESim simulation, load pressure, check valve displacement and flow rate under no load state were calculated, and performance analysis and changes in dynamic characteristics were confirmed by adding brake load. A jig for use in fixing the brake load during performance test was manufactured. The flow rate was assessed under no load condition and load pressure formation experiments were performed and compared with simulation results. Experimental results revealed the maximum load pressure as about 73bar at 130Hz and the maximum flow rate as about 203cc/min at 145Hz, which satisfied the requirement of small- and medium-sized UAV braking system. In addition, simulation results revealed that the load pressure and discharge flow rate were within 6% and 5%, respectively. Apparently, the modeling is expected to be effective for brake performance analysis.

Pressurization Characteristics of Piezoelectric-Hydraulic Pump Adopting a Ball-Thin Plate Spring Type Check Valve (볼-박판 스프링 형 체크밸브가 적용된 압전유압펌프의 가압 특성)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • In this study, a new check valve was studied to improve the load pressure of a brake system with a small piezoelectric-hydraulic pump. During the pressurization process, the steady-state pressure at the load is affected by the ratio of the cross-sectional area of the check valve the chamber pressure and load pressure. Since the flow path cover of the check valve is made wider than the cross-sectional area of the output flow to prevent backflow, a method of reducing the area ratio is proposed for a higher load pressure by mounting an additional mass to a thin plate spring type check valve. To identify the effect of mounting an additional mass to the existing check valve on the load pressure, a simple brake system with a small piezoelectric-hydraulic pump was modeled using a commercial code AMESim. The AMESim modeling was verified by comparing the simulation results with the experimental results of the pump the existing check valve. The additional mass was added to the verified AMESim modeling and higher load pressure was able to be obtained through simulation. The 35% performance improvement in load pressure identified by carrying out pressurization test of the brake system after adopting the new check valve the small piezoelectric-hydraulic pump.

Dynamic Analysis on the Tail Gate System for Vehicle with the Energy Regenerative Brake of Hydraulic Driven Systems (유압 구동계 에너지 재생 브레이크를 적용한 자동차 테일게이트 개폐장치에 대한 동특성 해석)

  • Choi, Soon-Woo;Huh, Jun-Young
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 2010
  • The typical trunk lid system for vehicle is composed of a hinge having 4-bar link and gas lifter. Here, the energy regenerative brake of hydraulic driven systems is applied to the tail gate system for vehicle and removed the gas lifter. The new tail gate system is composed of a hydraulic pump by electric motor, a hydraulic motor, four check valves, an accumulator, a relief valve and a directional control valve. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action. The capacity selection method of accumulator by mathematical model is based upon trial and error approach and computer simulation by AMEsim software is carried out.

  • PDF

On the Performance Test of the Piezoelectric-Hydraulic Pump (압전유압펌프 성능실험에 대한 연구)

  • Joo, Yong-Hwi;Hwang, Jai-Hyuk;Yang, Ji-Youn;Bae, Jae-Sung;Lee, Jong-Hoon;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.822-829
    • /
    • 2015
  • In this paper, the piezoelectric-hydraulic pump with a piezostack actuator as a driving source has been designed, fabricated, and evaluated for its application to UAV's brake system. The performance requirements of the piezoelectric-hydraulic pump were decided based on the requirements analysis of the target aircraft brake system. The geometric design of the piezoelectric-hydraulic pump to meet the performance requirements of the pump was conducted, and all components of the pump including the spring sheet type check valves were machined with close tolerance. By constructing a test apparatus for the performance check of the piezoelectric-hydraulic pump, the performance characteristics of the pump, such as the outlet flow rate for load-free condition and the outlet oil pressure for closed loop condition, have been evaluated. It has been found by the performance test result that the developed piezoelectric-hydraulic pump satisfies the design requirements effectively.

Pressure Control of Brake Circuit with Piezoelectric-hydraulic Pump Using Pressurization/Depressurization Characteristics (압전유압펌프가 적용된 브레이크 회로의 가감압 특성을 이용한 압력 제어)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung;Kwon, Jun-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.8-15
    • /
    • 2017
  • In this paper, an equivalent brake hydraulic circuit with a piezoelectric hydraulic pump was constructed, and load pressure control for better pressurization/depressurization characteristics was conducted. To understand pressurization/depressurization characteristics of the equivalent hydraulic circuit, the relation between the load pressure and the input voltage was revealed experimentally. Experiments were also conducted to observe effect of the solenoid valve on depressurization characteristics. In the pressurization experiment, it was validated that transient response time required to achieve desired load pressure may be reduced through voltage control to change pressurization gradient. By applying the valve on/off time control and voltage control, it was also possible to reduce response time in the depressurization process. Therefore, transient response time may be improved within 10ms for pressurization and within 30 ms for depressurization using the control technique suggested in this study. The load pressure control method proposed in this study is useful for controlling load pressure of a hydraulic brake system with the piezoelectric hydraulic pump.

Design Parameters Considering Friction Characteristics for Rope Brake System of Elevator (로프 브레이크 시스템에서 마찰 특성을 고려한 설계 변수특성 연구)

  • Jang, Joosup
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.171-179
    • /
    • 2013
  • In this study, hydraulic systems of the rope brake system of an elevator are modeled to evaluate design parameters that consider friction characteristics such as cylinder pressure, piston displacement, and flow rate. Hydraulic systems of the rope brake system are analyzed using the commercial program AMESim. Analysis modeling data are compared with data obtained from experiments, and the analysis modeling results are found to be reliable. The analysis results will be used to design hydraulic systems of the rope brake system of elevators.