• Title/Summary/Keyword: 유수 분리장치

Search Result 15, Processing Time 0.018 seconds

Development of Oil Content Meter for Oily Water Separator in Ship (선박 유수분리기용 유분검출기의 개발)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

Study of factor of Bilge Separator for oily water emulsion conforming with new IMO regulation (신 IMO 협약에 따른 에멀젼 분리형 선박용 유수분리기 영향인자에 관한 연구)

  • Lim, Jae-Dong;Park, Sun-Jung;Park, Sang-Ho;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.103-108
    • /
    • 2006
  • Treatment of O/W Emulsion is very important to develop 15ppm Bilge Separator for new IMO regulation It is too difficult to demulsify the emulsion in the bilge waste water, so we use chemical treatment to break emulsion stability. Broken oil particle is treated by flotation 15ppm Bilge Separator on the Ship doesn't have enough time to treat Bilge waste water because of limited space in the ship. For the solution to this problem, we experiment to find primary factors as coagulant, pH, amount of inputting coagulant, and type of flotation. On the basis of test results, we decided primary factors.

  • PDF

An Effect of Laminated Plate on the Performance of Pre-separator for Marine Oily Water Separator (선박 유수분리기 전처리 장치 성능에 미치는 적층판의 영향)

  • 이진열;한원희
    • Tribology and Lubricants
    • /
    • v.16 no.6
    • /
    • pp.440-447
    • /
    • 2000
  • It's a tendency to strengthen related international laws as the importance on marine oil pollution recently becomes the issue. According to the regulation of IMO, oil discharge from ships is allowed under 15 ppm only and oil filtering equipment is essential. However, for large ships using heavy fuel oil of over S.G 0.98 and viscosity 380 cSt and system oil, it has been in difficulty to process with existing filtering type of oily water separator. Oily water pre-separator of laminated plate type which is one of gravity type separator has very simple structure and it also makes easier to maintain and repair. In another words, it fits well to process large amount of rich oil with high specific gravity. In this paper, oily water pre-separator of laminated plate type has been studied. The function of emulsified oil and 4 different types of oil have been analyzed and each character has been investigated and proved by experiments. As the result of it, the efficiency of separating oil water has been advanced by 10% in case equipped with pre-separator. In addition, the higher temperature is and the more laminated plate has, it turns out to be getting more effect.

Study of development of Bilge Separator for new IMO Regulation I - Demulsification - (IMO 협약 개정에 따른 Bilge Separator 개발에 관한 연구 I - 에멀젼 분리에 관한 연구 -)

  • Lim Jae-Dong;Park Sang-Ho;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.175-179
    • /
    • 2005
  • Treatment of Emulsion is very important to development of Bilge Separator for new IMO Regulation. It is too difficult to demulsify the emulsion in the bilge waste water, so we use chemical treatment to break emulsion stability. Broken oil particle is treated by flotation. Bilge Separator on the Ship doesn't have enough time to treat Bilge waste water because of small space in the ship. For the solution to this problem, we experiment to find primary factor as coagulator, pH, and amount of coagulator. As the basis of test, we decided coagulator, pH and quantity of coagulator.

  • PDF

Treatment of Contaminated Groundwater Containing Petroleum and Suspended Solids Using DAF and Mixed Coagulation Processes (DAF와 혼화응집공정을 이용한 현탁성 고형물 함유 유류 오염 지하수 처리)

  • Lee, Chaeyoung;Jang, Yeongsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.25-32
    • /
    • 2010
  • Contamination of soil and groundwater by the compounds of hydrocarbon petroleum has been widely accepted as the main cause that harms the environments and health. To remove those pollutants, absorbing clothes, activated carbons, or oil-water separation devices with the gravity method are employed for treatment. However, those materials and devices cannot remove the emulsion pollutants despite of their efficiency for removing free products. Therefore, we investigated the problems which occur during the groundwater treatment for the highly concentrated suspended solid particles, which can be resulted from excavation, and to propose methods to remove TPH(Total Petroleum Hydrocarbon). After coagulation experiment with high molecular polymers, the concentration of SS(Suspended Solids) and COD(Chemical Oxygen Demand) turned to satisfy the groundwater quality criteria within 5 minutes while the concentration of TPH failed to meet the water quality standard of effluent. Consequently, the water quality criteria for effluent could not be met by single DAF(Dissolved Air Flotation) process. However all water quality criteria could be satisfied after 20 minutes when coagulation reactions are carried out simultaneously in the DAF reactor.