• 제목/요약/키워드: 유방조직 팬텀

Search Result 25, Processing Time 0.039 seconds

Comparison of Digital Mammography and Digital Breast Tomosynthesis (디지털 유방촬영기기와 3차원 디지털 유방단층영상합성기기의 비교연구)

  • Kim, Ye-Seul;Park, Hye-Suk;Choi, Jae-Gu;Choi, Young-Wook;Park, Jun-Ho;Lee, Jae-Jun;Kwak, Su-Bin;Kim, Eun-Hye;Kim, Ju-Yeon;Jung, Hyun-Jung;Lee, Haeng-Hwa;Bae, Gyu-Won;Lee, Mi-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.261-268
    • /
    • 2012
  • Breast cancer is the second leading cause of women cancer death in Korea. The key for reducing disease mortality is early detection. Although digital mammography (DM) has been credited as one of the major reasons for the early detection to decrease in breast cancer mortality observed in the last 20 years, DM is far from perfect for several limitations. Digital breast tomosynthesis (DBT) is expected to overcome some inherent limitations of conventional mammography caused by overlapping of normal tissue and pathological tissue during the standard 2D projections for the improved lesion margin visibility and early breast cancer detection. In this study, we compared a DM system and DBT system acquired with different thickness of breast phantom. We acquired breast phantom data with same average glandular dose (AGD) from 1 mGy to 4 mGy under same experimental condition. The contrast, micro-calcification measurement accuracy and observer study were conducted with breast phantom images. As a result, the higher accuracy of lesion detection with DBT system compared to DM system was demonstrated in this study. Furthermore, the pain of patients caused by severe compression can be reduced with DBT system. In conclusion, the results indicated that DBT system play an important role in breast cancer detection.

Comparison and validation of Brass mesh bolus using tissue equivalent bolus in the breast cancer radiotherapy (유방암 방사선치료시 조직등가보상체와의 비교를 통한 Brass mesh bolus의 유용성 평가)

  • Bong, Juyeon;Kim, Kyungtae;jeon, Mijin;Ha, Jinsook;Shin, Dongbong;Kim, Seijoon;Kim, Jongdae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.93-101
    • /
    • 2017
  • Purpose: In breast cancer radiotherapy, brass mesh bolus has been recently studied to overcome disadvantage of conventional bolus. The purpose of this study is to investigate the stability of first introduced the brass mesh in the country, and evaluate the skin surface dose of that. Materials and Methods: The measurement of skin surface dose was evaluated to verify similar thickness of the Brass mesh bolus that compared conformal tissue equivalent bolus with 5 mm thickness. We used 6 MV photons on an ELEKTA VERSA linear accelerator and optically stimulated luminescent dosimeter (OSLD). In addition, two opposed beam using IMRT phantom was applied to comparative study of brass mesh bolus between tissue equivalent bolus. Results: The results showed that similar thickness of the Brass mesh bolus was 3 mm compared with 5 mm tissue equivalent bolus by measuring the skin surface dose of solid phantom. The surface dose for IMRT thorax phantom using 3 mm brass mesh bolus was about 1.069 times greater than that using tissue equivalent bolus. Conclusion: In this study, we found that the brass mesh bolus improved better reduction of skin sparing effect and dose uniformity than tissue equivalent bolus. However evaluation for various clinic cases should be investigated.

  • PDF

Magnetic Resonance Current Density Imaging

  • 오석훈;이원희;이항로;한재용;우응제;조민형;이수열
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.99-99
    • /
    • 2002
  • 목적: 인체에 전류를 주입하면 체내의 생체조직의 임피던스 분포에 따라서 전류밀도 분포가 결정된다. 이러한 전류밀도 분포에 대한 정보는 전기임피던스 단층촬영법과 유방암 진단, 체내 온도 분포의 영상화, 전기자극에 의한 체내 전류 경로의 시각화에 대한 연구에 응용될 수 있다. 한편 이러한 전류밀도 분포는 전류주입 자기공명영상기법에 의해 영상화할 수 있으며, 본 논문은 3차원 팬텀 내부의 전류밀도 분포를 영상화하는 전류주입 자기공명영상기법의 실험결과를 기술한다.

  • PDF

Reproducibility Evaluation of Shear Wave Elastography According to the Depth of the Simulated Lesion in Breast Ultrasonography (유방초음파 검사에서 모조 병소의 깊이에 따른 전단파 탄성초음파의 재현성 평가)

  • Jin-Hee Kim;In-Soo Kim;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.919-927
    • /
    • 2023
  • Elastography utilizes the fact that the tissue of a malignant tumor is harder than that of a benign tumor and increases the specificity of diagnosis according to the elastic modulus of the tumor, helping to reduce unnecessary biopsies. However, the reliability of elastography can be influenced by the equipment used and the examiner's skills. In this study, the researchers analyzed the reproducibility of elastography by evaluating phantom images when measuring the elasticity values repeatedly. Phantoms were created using silicone and gelatin with different levels of stiffness, and they were inserted at varying depths from the surface. The elasticity values were measured using shear wave elastography. The study aimed to determine whether the reproducibility of elasticity values remains consistent depending on the stiffness and depth of the lesions. The experimental results showed that there was no statistically significant correlation between the elasticity values obtained through shear wave elastography and the depth or stiffness of the lesions. However, in the lesions with the lowest stiffness, the elasticity values were statistically significant (p<0.001) and showed a high correlation with the depth of the lesions. Although there were variations in the measured elasticity values based on the differences in lesion stiffness and depth, these differences did not significantly impact the diagnosis. Therefore, shear wave elastography remains a reliable diagnostic method, and it is suggested that it can be helpful in the diagnosis of breast lesions.

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Development of Tissue mimicking ultrasound phantom materials (Tissue mimicking 초음파 팬텀물질의 개발에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Park, Ki-Jung;Lee, Suk
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.51-62
    • /
    • 2003
  • We carried out studies on develop of the ultrasound tissue mimicking materials(TMM) by synthesis of polymer urethane(C, CCR, $TiO_2$, tungsten, graphite, silver type). The major finding were as follows; (1) C type TMM was shown good homogeneity, penetration, gray scale like as liver tissue and propagated speed 1,540 m/s, attenuation $0.5{\sim}0.7\;dB/cm/MHz$. (2) $TiO_2$ type TMM was shown heterogeneous dot echo pattern. (3) Silver type TMM was appear good homogeneous echo pattern like as echo texture of thyroid gland. Therefor, C type TMM will be useful for ultrasound Q/A phantom materials and previous phantom materials.

  • PDF

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성

  • 추성실;김성규
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.52-52
    • /
    • 2003
  • 악성종양을 치료하는 방법중 방사선과 온열요법은 가장 강력한 치료방법으로 연구되어왔으며 이를 병용함으로 서 상승효과를 얻을 수 있다. 인체조직에 41$^{\circ}C$ 이상의 열을 가하면 세포질의 단백질변성으로 세포에 손상을 주어 세포가 사멸하게 되며 세포의 생존율은 가열시간 즉 열량에 따라 지수적으로 감소한다. 온열은 세포주기중 방사선 저항성이 매우 큰 DNA 합성시기와 산도가 높을 때 감수성이 매우 크기 때문에 방사선과 병용요법은 상호 상승효과를 가져온다. 이와 같이 온열을 이용한 악성종양의 치료가능성은 생물학적 기초연구와 임상시험에서 경이적인 효과를 얻을 수 있었으나 아직 까지 가열방법과 온도분포측정이 큰 과제로 남아있으며 주위건강조직의 가열을 피하면서 인체 깊은 곳에 존재하는 종양에만 집중 가열하는 방법인 삽입형 온열치료방법에 대한 연구가 집중되었다. 한편 방사선 치료방법은 주위 건강조직의 피폭을 최소로 줄이고 종양에만 집중 조사가 요구되며 자궁암, 유방암, 뇌암등 부피가 작고 집중적 치료를 요하는 종양은 방사성동위원소를 이용한 근접 삽입치료 (Brachyradiotherapy)가 큰 효과를 나타내고 있다 방사선과 온열의 병행 치료를 위하여 방사선 삽입 치료에 사용한 선원 삽입관을 그대로 두고 삽입관 속에 방사성 동위원소 대신 온열 전극을 넣어 열을 가하는 방사선 온열 병용치료방법을 고안하였으며 방사선과 온열병용에 사용할 최적 삽입관의 제작과 이에 따른 온도분포의 측정과 최적삽입방법을 결정하였다. 방사선 삽입치료용 폴리에찌렌 삽입관의 외부에 금박을 입혀 라디오파 첨극을 삽입할 때 서로 연결되도록 고안 제작함으로서 방사선 삽입치료와 자입식 온열치료를 동시에 만족하게 수행할 수 있는 병용삽입관 (Flexible thermoradiotherapy probes)을 제작하였다. 전도율이 큰 금박부위가 직접 조직에 접촉됨으로 라디오파의 전달이 용이하며 금박의 길이를 2 cm 에서 5 cm 로 구분제작 함으로서 종양의 크기와 모양에 따라 선택할 수 있도록 하였다. 라디오파를 이용한 온열분포의 측정은 인체조직과 전기적 특성이 비슷한 물질인 한천 팬텀 제작하여 사용하였으며 온도분포 측정은 열전대와 서머그람으로 시행하였다. 생체조직 내에서의 온도분포와 온열효과를 관찰하기 위하여 직접 개의 뇌를 이용하여 시행하였으며 4 개의 전극을 이용하여 43$^{\circ}C$로 50분간 가열하고 일주일후 개를 회생시켜 개 뇌에 대한 조직학적 검사를 시행하였다. 한편 팬텀 표면에서 중앙부로 안테나 길이가 2 cm 인 4 개의 전극을 1 cm 간격으로 정사각형이 되도록 삽입하여 가열하였을 때 90% 등온곡선이 반경 1.25의 원형으로 균일하게 분포되었고 종단면상 삽입관의 길이에 따라 균일한 온도분포가 이루어졌다. 전극을 2 cm 간격으로 삽일 하였을 때 90% 등온곡선이 1.75 반경으로 거의 4 각형의 균일한 분포를 얻었으나 전극의 간격이 증가하면 전도율이 떨어져서 전극 중심부에 불균일한 온도분포를 형성하였다. 동물실험에서 정상 개의 뇌 실질에 자입하여 직접 정방형의 중심을 43$^{\circ}C$로 유지하며 50분간 온열 요법을 시행한 후 관찰한 조직병리학적 소견은 liquefactive necrosis, pyknosis of neuronal element 및 polymorphonuclear leukocytes들의 회백질에서 급성기에 관찰되었고 liquefactive necrosis 주위에 lipid-laden macrophage들이 관찰됨이 공통적인 특정이었으며 후기변화로 괴사조직 주위로 신경교세포의 증식이 관찰되었다.

  • PDF