• 제목/요약/키워드: 유방엑스선검사

검색결과 4건 처리시간 0.019초

유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교 (Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography)

  • 안세정;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.

유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가 (Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography)

  • 엄현자;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.

보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로 (A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021)

  • 장현철
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.667-673
    • /
    • 2021
  • 4차 산업혁명 시대에 진입하면서 방사선 의료 기술 개발의 혁신 및 고도화에 따라 방사선사의 업무 범위는 더욱더 확대될 것으로 판단된다. 본 연구에서는 의료장비 및 방사선사 인력 현황을 파악하여 4차 산업혁명시대 변화에 있어 방사선 의료기술분야 인재 양성 계획, 진로 및 취업 상담에 기초자료를 제공하고자 하였다. 보건의료 빅데이터를 이용하여 2020년부터 2분기 자료와 2021년 2분기 자료를 통해 분석하였다. 연구결과 2020년 대비 2021년 종별 의료장비 현황 비교 결과 C-Arm X-선 검사 장비가 6,638대로 5.83% 가장 높게 증가하였으며, 다음 순으로 MRI 검사 장비 1,811대 5.29%, 혈관조영 검사 장비 725대 5.22%, 일반 X-선 검사 장비 21,557대 3.99%, CT 검사 장비 2,136대 3.03%, 유방 검사 장비 3,425대 3.00% 증가하였다. 2020년 대비 2021년 전체 방사선사 인력 현황 비교 결과 29,038명으로 2.73% 증가하였다. 지역별 방사선사 인력 현황 비교 결과 경기 지역에서 5.96%로 가장 높게 증가하였으며, 다음순으로 강원 지역 5.66%, 충남지역 3.81% 증가하였다. 의료장비 및 방사선사 인력이 증가하는 상황에서 대학에서는 4차 산업혁명 시대의료 방사선 기술영역에서 적용할 수 있는 맞춤형 인공지능 및 빅데이터에 관한 이해 및 활용과 관련된 교과목 개발을 통한 전문적 지식과 실무역량을 갖춘 방사선사 양성이 필요하며, 협회 차원에서는 새로운 일자리 창출 및 취업 향상을 위한 적극적인 정책이 필요할 것으로 생각된다.

IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징 (Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0)

  • 김현지;김정민;최인석;윤용수;서덕남;김정수;김대영;박성용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2013
  • IEC 규격은 유럽, 일본 등 해외 여러 나라에서 자국의 규격으로서 이용되고 있으며, 우리나라에서는 현재 산업표준인 KS 형태와 더불어 강제성을 갖는 식품의약품안전청 고시로서도 발행되고 있다. 전자의료기기에 관한 IEC 규격인 IEC 60601 시리즈의 공통규격(IEC 60601-1:2005)이 3판으로 개정됨에 따라, 보조규격과 개별규격 또한 그에 맞추어 제 개정이 필요하다. IEC 규격의 변화 동향을 파악하는 것은 국내 의료기기 제조 수입업체 및 시험검사기관에서 매우 중요하다. 따라서 본 연구에서는, 진단용X선기기와 관련한 3개 규격 IEC 60601-2-44(CT의 기본안전과 필수성능에 관한 규격), IEC 60601-2-45(유방촬영용X선장치의 기본안전과 필수성능에 관한 규격), IEC 60601-2-54(진단용 X선장치의 기본안전과 필수성능에 관한 개별규격)에 대하여 IEC 60601-1의 3판에 맞추어 제 개정된 최신판의 동향 및 특징을 살펴보고자 하였다. 또한 현행 식품의약품안전청 고시가 IEC 60601-1의 2판이 적용된 개별규격을 참고로 하고 있어, 현행 식품의약품안전청 고시와 대비하여 그 특징을 살펴보았다. IEC 60601-1의 3판이 적용된 진단용X선장치 외 2개의 IEC 개별규격의 특징은 다음과 같다. 1) 기계적 위해요인, 특히 움직이는 부분에 대한 내용이 강화되었다. 2) 환자 선량을 표시 및 기록하도록 명시하고 있다. 3) 잠재적인 위험요소에 대해 체계적으로 관리가 가능한 위험관리 프로세스를 도입하고 있다. 4) 과거 Film-Screen System과 더불어 DR system(digital radiography system)에 대해서도 적용하고 있다. 현재 IEC 60601-1의 3판이 적용된 개별규격이 식품의약품안전청 고시로 개정될 예정이므로, 국내 시험 검사기관 및 의료기기 제조 수입업체 등에 유용한 자료가 되기를 기대한다.