• Title/Summary/Keyword: 유량 확보

Search Result 707, Processing Time 0.038 seconds

Cross-flow Nanofiltration of PCB Etching Waste Solution Containing Copper Ion (구리이온을 함유한 PCB 폐에칭액의 Cross-flow 나노여과)

  • Park, Hye-Ri;Nam, Sang-Won;Youm, Kyung-Ho
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.272-277
    • /
    • 2014
  • In this study the nanofiltration (NF) membrane treatment of a sulfuric acid waste solutions containing copper ion ($Cu^{+2}$) discharging from the etching processes of the printed circuit board (PCB) manufacturing industry has been studied for the recycling of acid etching solution. SelRO MPS-34 4040 NF membrane from Koch company was tested to obtain the basic NF data for recycling of etching solution and separation efficiency (total rejection) of copper ion. NF experiments were carried out with a cross-flow membrane filtration laboratory system. The permeate flux was decreased with the increasing copper ion concentration in sulfuric acid solution and lowering pH of acid solution, and its value was the range of $4.5{\sim}23L/m^2{\cdot}h$. Total rejection of copper ion was decreased with the increasing copper ion concentration, lowering pH of acid solution and decreasing cross-flow rate. The total rejection of copper ion was more than 70% at the experimental condition. The SelRO MPS-34 4040 NF membrane was represented the stable flux and rejection for 1 year operation.

Fractional efficiency of Nanomaterials for the High efficiency respiratory filters (고효율 호흡보호구의 나노물질 입경별 제거 효율)

  • Lee, Gwang-Jae;Ji, Jun-Ho;Kim, Won-Geun;Yook, Se-Jin;Kim, Jong-Kyo;Kim, Jung-Ho
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • Controlling exposures to occupational hazards is important for protecting workers. Certified facepiece respirators are recommended when engineering controls do not adequately prevent exposures to airborne nanomaterials. The objective of this study is to carry out the experimental performance test to investigate the fractional efficiencies of the filter media for two grades of facepiece respirators. Experimental performance evaluations were carried out for the test NaCl particles and silver nanoparticles. For media of respirator filter, the penetration of NaCl particles was less than 5% and the most penetrating particle size occurred at about 40 nm. For silver nanoparticles, the most penetrating particle size was about 20nm with higher efficiency than those of NaCl particles. Charge characteristics of airborne nanoparticles is important because the media of respirator filter is made by the electret filter media.

Numerical Study on the Performance Assessment for Defrost and De-Icing Modes (승용차의 제상 및 성에 제거 성능 평가를 위한 수치해석적 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.161-168
    • /
    • 2011
  • The heating, ventilating, air conditioning (HVAC) system is a very important part of an automotive vehicle: it controls the microclimate inside the passenger's compartment and removes the frost or mist that is produced in cold/rainy weather. In this study, the numerical analysis of the defrost duct in an HVAC system and the de-icing pattern is carried out using commercial CFX-code. The mass flow distribution and flow structure at the outlet of the defrost duct satisfied the duct design specification. For analyzing the de-icing pattern, additional grid generation of solid domain of ice and glass is pre-defined for conductive heat transfer. The flow structure near the windshield, streakline, and temperature fields clearly indicate that the de-icing capacity of the given defrost duct configuration is excellent and that it can be operated in a stable manner. In this paper, the unsteady changes in temperature, water volume fraction, and static enthalpy at four monitoring points are discussed.

Simulation of Water Quality Changes in the Saemangeum Reservoir Induced by Dike Completion (방조제 완공에 따른 호내부 수질변화 모의)

  • Suh, Seung-Won;Lee, Hwa-Young;Yoo, Sang-Cheol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.258-271
    • /
    • 2010
  • In order to figure out hydrodynamic and water quality changes after completion of dike construction of the Saemangeum, which behaves as a semi-enclosed estuarine lake, numerical simulations based on fine grid structure by using EFDC were intensively carried out. In this study some limitations of precedent study has been improved and gate operation were considered. Also 3 phases such as air-water-sediment interaction modeling was considered. It is clear that inner mixing of the Saemangeum is dominated by Mankyeong and Dongjin riverine discharges rather than the gate opening influence through the Lagrangian particle tracking simulations. Vertical DO structure after the dike completion shows steep gradient especially at Dongjin river estuary due to lessen of outer sea water exchange. Increasing SOD at stagnantly changed man-made reservoir might cause oxygen deficiency and accelerating degradation of water quality. According to TSI evaluation test representing eutrophication status, it shows high possibility of eutrophication along Mankyeong waterway in spite of dike completion, while the index is getting high after final closing along Dongjin waterway. Numerical tests with gate operations show significant differences in water quality. Thus it should be noted that proper gate operation plays a major role in preserving target water quality and management for inner development plan.

Sedimentation Deposit in Surcharged Manhole with 90 Degree Bend (과부하 $90^{\circ}$ 접합맨홀에서의 유사퇴적)

  • Song, Ju-Il;Kim, Ju-Hyung;Rim, Chang-Soo;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.317-317
    • /
    • 2011
  • 맨홀 및 관로에 퇴적되는 유사는 우수관거의 통수능을 감소기키고 우수관거 시스템의 효율을 저하시켜, 맨홀에서 역류를 발생시켜 저지대 침수의 한 원인인 되고 있다. 또한 관거내에서 유수가 일정한 유속을 확보하지 못하면 오염물이 침전되고, 관거내 유하시간이 길어져 침전물 부패로 인한 황화물질 및 악취 등이 발생할 수 있다. 따라서 우수 및 하수관거 시스템에서 유사와 관련된 주된 연구는 관거내의 유사거동 특성을 규명하고자 하는 것이었다. 그러나 맨홀과 관련하여서는 맨홀내의 오염물 지체시간 및 확산 특성분석이 전부였고, 유사의 퇴적 및 배출 등과 관련된 거동특성 연구는 매우 미흡한 실정이다. 본 연구에서는 유입관과 유출관이 $90^{\circ}$로 접합된 맨홀을 대상으로 수리실험을 실시하고, 맨홀형태(사각형, 원형), 유사유입형태(연속주입, 일정기간주입), 유사종류(주문진표준사, 모래), 유사유입량 및 맨홀내부형상 변화에 따른 맨홀내 유사퇴적량을 확인하였다. 실험결과 그림 1과 같이 $90^{\circ}$ 접합맨홀에서는 유사유입형태와 무관하게 유입유사량이 증가할수록 퇴적량 또한 증가하였다. 그러나 유사퇴적량은 사각형맨홀보다 원형맨홀에서 적었다. 이는 관거가 $90^{\circ}$로 접합된 맨홀내에서의 유사거동 양상은 우선 유입되는 유사가 맨홀바닦에 퇴적되고 와류에 의해 부유되는 유사가 유출관을 통해 배출되는데 사각형맨홀에 비하여 원형맨홀에서 와류가 더 크게 형성되기 때문인 것으로 판단된다. 유사가 일정기간주입되는 경우 원형맨홀 내부에 퇴적되는 유사량은 거의 없었다. 사각형맨홀내부에 벤칭을 설치한 경우 설치전과 비교하여 퇴적량은 50%이상 저감되었고, 일정기간주입시에는 벤칭 설치 후 유사퇴적량은 거의 없었다. 유입유사가 모래인 경우 맨홀내 퇴적량은 주문진표준사와 비교하여 증가하였다. 모래는 주문진 표준사와 비교하여 중량이 크다. 따라서 같은 흐름조건에서 주문진표준사와 비교하여 부유되는 유사량이 적고, 배출되는 유사량 또한 적었다. 유량과 관거유속이 동일한 조건에서 유출관과 유입관이 일직선상으로 연결된 중간맨홀내부에 퇴적된 주문진표준사의량과 비교하여 $90^{\circ}$ 접합맨홀의 퇴적량이 상대적으로 적었다. 이 또한 앞서 기술한 와류의 영향으로 판단된다. 일반적으로 $90^{\circ}$접합맨홀내부에서 발생하는 와류가 중간맨홀보다 크고, 이로 인해 에너지손실은 커지지만 유사거동과 관련하여서는 와류가 크게 발생하는 맨홀조건에서 퇴적량이 적음을 실험적으로 확인하였다.

  • PDF

Technical Evaluation of MBR Process for the Wastewater Treatment of Beverage Fabrication Processes (음료수 제조 공정 폐수의 MBR 처리 기술 평가)

  • Jung, Cheol Joong;Park, Jong Min;Kim, Youn Kook
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • Manufacturing facility for non-alcoholic drink, the parts of the food industry, disposes wastewater which includes high organic concentration and low nitrogen, phosphorus concentration. For this kind of wastewater, the treatment plant consists mainly of aerobic reactor and chemical coagulation process. And sand-filter or activated carbon process is normally installed further. However, aerobic reactor must have long HRT to treat high concentration of organic contaminant included in this wastewater, so the large site area is required. And settling tank which is normally applied for wastewater treatment facility has some problems such as water quality degradation caused by the sludge spill. To solve these problems, we applied MBR system for the wastewater. And the MBR pilot plant was installed nearby the wastewater treatment facility of W food factory and operated during long term to evaluate treatment efficiency. This plant was operated about 3 months and than the result was 97% of organic removal rate on conditions of flow rate $20m^3/day$, HRT 29 hr, recycle 4Q. However, contaminant removal ratio of bio-reactor decreased and TMP of membrane increased rapidly on more conditions.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

Pulsed DC $BCl_3/SF_6$ 플라즈마를 이용한 GaAs와 AlGaAs의 선택적 식각에 관한 연구

  • Choe, Gyeong-Hun;Kim, Jin-U;No, Gang-Hyeon;Sin, Ju-Yong;Park, Dong-Gyun;Song, Han-Jeong;Lee, Je-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.67-67
    • /
    • 2011
  • Pulsed DC $BCl_3/SF_6$ 플라즈마를 사용하여 GaAs와 AlGaAs의 건식 식각을 연구하였다. 식각 공정 변수는 가스 유량 (50~100 % $BCl_3$ in $BCl_3/SF_6$), 펄스 파워 (450~600 V), 펄스 주파수 (100~250 KHz), 리버스 시간 (0.4~1.2 ${\mu}s$)이었다. 식각 공정 후 표면 단차 측정기 (Surface profiler)를 사용하여 표면의 단차와 거칠기를 분석하였다. 그 결과를 이용하여 식각률 (Etch rate), 표면거칠기 (Surface roughness), 식각 선택비 (Selectivity)와 같은 특성 평가를 하였다. 실험 후 주사 현미경 (FE-SEM, Field Emission Scanning Electron Microscopy)을 이용, 식각 후 시료의 단면과 표면을 관찰하였다. 실험 결과에 의하면 1) 18 sccm $BCl_3$ / 2 sccm $SF_6$, 500 V (Pulsed DC voltage), 0.7 ${\mu}s$ (Reverse time), 200 KHz (Pulsed DC frequency), 공정 압력이 100 mTorr인 조건에서 GaAs와 Al0.2Ga0.8As의 식각 선택비가 약 48:1로 우수한 결과를 나타내었다. 2) 펄스 파워 (Pulsed DC voltage), 리버스 시간(Reverse time), 펄스 주파수(Pulsed DC frequency)의 증가에 따라 각각 500~550 V, 0.7~1.0 ${\mu}s$, 그리고 200~250 KHz 구간에서 AlGaAs에 대한 GaAs의 선택비가 감소하게 되는 것을 알 수 있었다. 이는 척 (chuck)에 인가되는 전류와 파워를 증가시키고, 따라서 GaAs의 식각률이 크게 증가했지만 AlGaAs 또한 식각률이 증가하게 되면서 GaAs에 대한 식각 선택비가 감소한 것으로 생각된다. 3) 표면 단차 측정기와 주사전자현미경 사진 결과에서는 GaAs의 경우 10% $SF_6$ (18 sccm $BCl_3$ / 2 sccm $SF_6$)가 혼합된 조건에서 상당히 매끈한 표면 (RMS roughness < 1.0 nm)과 높은 식각률 (~0.35 ${\mu}m$/min), 수직의 식각 측벽 확보에서 매우 좋은 결과를 보여주었다. 또한 같은 공정 조건에서 AlGaAs는 식각이 거의 되지 않은 결과 (~0.03 ${\mu}m$/min)를 보여주었다. 위의 결과들을 종합해 볼 때 Pulsed DC $BCl_3/SF_6$ 플라즈마는 GaAs와 AlGaAs의 선택적 식각 공정에서 매우 우수한 공정 결과를 나타내었다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.118-118
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M 냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler (G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K와 1st STG Temp. 80K를 Heat Load기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF