• Title/Summary/Keyword: 유량 제어

Search Result 784, Processing Time 0.232 seconds

Plant Cooldown Test Simulation After Steam Generator U-Tube Rupture under Onsite Power Available Without Safety Injection (증기발생기 세관파열사고 후 소외전원 가용 및 비상냉각수 주입 배제 조건하에서의 발전소냉각에 관한 실험 모사)

  • Kim, Du-Ill;Kim, Hee-Cheol;Auh, Geun-Sun;Kim, Joon-Sung;Park, Jae-Don
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.483-490
    • /
    • 1995
  • The objective of the PKL III A 4.4 experiment is to examine that the plant could be controlled by manually operative actions "after Steam Generator Tube Rupture under Offsite Power Available without Safety Injection". In order to verify the limitation and ability of the system code NLOOP in the expeiment simulation, the behaviors of the PKL III facility obtained in the experiment are compared with the results of NLOOP code. NLOOP code, which is originally developed to simulate the transients of the Westinghouse type PWRs by KAERI/SIEMENS, modified properly to simulate the PKL III facility. Particular attention is given to the RCS mass How rate of the natural circulation in loops and the termination behavior of the natural circulation in the isolated loop. The comparisons between the experimental and calculational results show the simulation ability and problems of the code. the code.

  • PDF

Analysis of Flow and Pollutant Reduction with LID using SWAT-SWMM coupled System at Kyoungan Watershed (SWAT-SWMM 연계모델 을 이용한 LID적용에 따른 경안천 유역의 유량 및 수질 개선 효과 분석)

  • Woo, Won-Hee;Ryu, Ji-Chul;Jang, Chun-Hwa;Kum, Dong-Hyuk;Lim, Kyoung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.92-92
    • /
    • 2012
  • 경안천은 팔당호로 직접 유입되는 하천 중 유입량 대비 오염도가 매우 높아 상수원보호를 위한 특별관리가 요구되는 지역이다. 또한 경안천 유역은 수도권과 인접하고 있어, 도시화에 의해 토지이용이 지속적으로 변화되고 있다. 이러한 토지이용의 변화는 불투수면적을 증가시켜 강우시 유출 및 수질오염 발생량을 증가시킨다. 그러므로 불투수면적 증가에 따른 영향을 줄이기 위해서는 친환경 도시개발에 적용하고 있는 LID기법을 도입하여, 개발지역의 불투수면적 발생을 최소화하여야 하며 오염원 발생을 사전에 제어해야 한다. 그러나 도시개발시 무분별한 LID기법 도입은 정부의 막대한 예산 및 인력낭비를 초래하므로 현장적용 전 모델링을 통해 LID기법의 기대효과 및 비용을 산출하여야 하며, 도시 계획 수립시 가장 효과적인 LID기법을 제시하여야 한다. 따라서 효과적인 LID기법을 제시하기 위해서는 LID기법 평가가 가능한 SWMM모형을 이용해야 한다. 하지만 경안천 유역과 같이 유역 내 도시 와 비도시지역이 혼재되어 있는 우리나라의 대부분의 유역은 SWMM모형만으로는 유역의 강우-유출 및 수질 평가가 불가능하기 때문에, 유역 내 도시와 비도시지역의 유출 및 수질관리 평가가 가능한 SWAT-SWMM 연계모델을 이용하여 유출량 및 수질관리 효과를 분석해야 한다. 본 연구에서는 SWAT-SWMM 연계모델을 이용하여 LID기법 별 시나리오를 구축하였고, 시나리오별 유출량 및 수질오염 발생량을 모의하여 분석하였다. 분석결과 상당량의 유출량 저감 및 수질개선 효과가 나타났다. 또한 SWAT-SWMM 연계모델을 이용하여 모의된 수질자료는 환경부에서 제시하고 있는 단위유역 대표지점 수질환경기준 달성의 객관적인 평가를 가능하게 한다. 향후 LID를 적용한 SWAT-SWMM 연계모델을 이용하여 정부에서 규제하는 개발제한구역이 포함된 유역에서의 도시개발시 수질환경기준에 맞는 친환경적인 개발을 할 수 있을 것이라 기대된다.

  • PDF

Evaluation of Risk Factors to Detect Anomaly in Water Supply Networks Based on the PROMETHEE and ANP (상수도관망의 이상징후 판정을 위한 위험요소 평가 - PROMETHEE와 ANP 기법 중심으로)

  • Hong, Sung-Jun;Lee, Yong-Dae;Kim, Sheung-Kown;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.1 s.162
    • /
    • pp.35-46
    • /
    • 2006
  • In this study, we proposed a layout of the integrated decision support system in order to prevent the contamination and to manage risk in water supply networks for safe and smooth water supply. We evaluated the priority of risk factors to detect anomaly in water supply networks using PROMETHEE and ANP techniques, which are applied to various Multi-Criteria Decision Making area in Europe and America. To develop the model, we selected pH, residual chlorine concentration, discharge, hydraulic pressure, electrical conductivity, turbidity, block leakage and water temperature as the key data item. We also chose pipe corrosion, pipe burst and water pollution in pipe as the criteria and then we present the results of PROMETHEE and ANP analysis. The evaluation results of the priority of risk factors in water supply networks will provide basic data to establish a contingency plan for accidents so that we can establish the specific emergency response procedures.

Analysis of Urban Watershed Flood according to Return Period using Inundation Model (범람해석모형을 이용한 재현빈도에 따른 도시유역의 침수해석)

  • Tak, Yong Hun;Hyun, Suk Hoon;Kim, Young Do;Kang, boo Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.91-91
    • /
    • 2015
  • 최근 강우패턴의 변화에 따라 동일한 강우에 대하여 도시지역에서 증가된 첨두유량을 보이며 도달시간이 단축되어 홍수의 위험성이 매우 높다. 도시화에 따라 하천변의 개발과, 불투수 지역의 증가로 배수관망의 분포에 따라 통수능을 초과하지 않는 소규모의 강우에도 내수배제불량에 의한 침수가 발생할 가능성을 지니고 있다. 이러한 도시유역의 침수방지를 위한 내수배제시설에는 배수문, 배수펌프, 저류지, 침투시설 등 다양한 홍수분담시설이 있지만, 기존 도시유역에서의 내수배제는 빗물펌프장 등 일부 구조물에만 치중되기 쉽다. 따라서 다양한 내수배제방안 및 그에 따른 효과를 종합적으로 고려한 내수배제시설의 설치가 필요하다. 도시화가 가중화되고, 인구의 증가와 사회기반시설이 밀집되어 있는 도시지역의 침수는 인명, 재산 및 주요 시설물에 대한 피해로 이어지게 된다. 그러므로 도시지역의 침수로 인한 피해저감에 있어 유출현상의 정확한 해석 능력은 홍수제어를 위한 홍수량의 예측과 배수 및 수방시설의 설계, 침수위험지역 선정 등에 있어서 매우 중요하다. 연구 대상지역은 최근 폭우발생시 침수피해가 빈번히 발생한 서울시의 도림천 유역을 선정하였다. 도림천 유역은 도심지를 관통하며 하천의 일부가 복개되어 하천이 큰 관로의 형태를 띠고 있으며, 하천의 범람, 관거 및 내수배제 불량에 의한 침수피해가 발생하고 있다. 본 연구에서는 도시침수에 대한 효율적인 내수배제를 위한 내수배제시설 설계를 위해 설계강우의 변동에 의한 유출량의 변화를 검토하여, 배수체계에서의 역류로 인한 월류량을 산정한 뒤 범람해석모형인 FLUMEN 모형에 적용하여 도시유역에서 우수의 거동에 관한 모의를 실시하였다.

  • PDF

An application of Smoothed Particle Hydrodynamics on intake system analysis in a dam (입자법을 이용한 댐 취수 운영의 3차원 해석 적용)

  • Kim, Sunghoon;Cho, Kwangjoon;Park, Chungik;Moon, Sukju;Kim, Jongchan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.92-92
    • /
    • 2019
  • 최근 기존의 격자방식의 해석 방법을 벗어나 해석 영역에 대한 분할을 별도로 고려치 않는 수치기법의 실무적 적용사례가 증가 하고 있으며, 이러한 방식중 SPH(Smoothed Particle Hydrodynamics) 방식이 근자에 수자원 분야에서도 도입되어 관수로 및 개수로 해석 또는 복합해석 등에 활용된 바 있다. 최초 도입된 무격자방식의 모형들은 주로 복잡한 형상을 지니는 유체기계 등에 활용성이 높았던 바, 큰 규모의 해석 도메인을 가지는 수자원 분야에서의 SPH의 실무적용 평가와 효율성의 확보를 위해서, 본 연구는 국내 댐을 시범 대상으로 하여 SPH 수치해석 툴을 적용하고자 하였다. 분석 대상댐은 국내 P댐으로서 관리수위의 변동은 크지 않으나, 댐 직상류의 만곡이 심하고 다수의 대규모 취수구를 가진 곳으로 상시 발전방류 및 수시 댐 수문방류에 의해 유체의 흐름이 2,3차원의 복잡성을 띄고있기 때문에, 3차원 전산유체역학 Tool의 적용이 적절한 것으로 판단하였다. 해석을 위해 하류경계조건을 댐축과 문비로 설정하였고 상류 1km까지를 해석의 도메인으로 설정하였다. 소요시간을 줄이기 위해 여러 번의 모의를 거쳐 입자의 평균 입경은 0.6m로 제안하고 시격은 1초 미만(평균 0.5초)로 설정하였다. 수문 및 발전방류는 해당댐의 1~2년 빈도 수준에 해당하는 $5,000m^3/s$ 이하의 유량을 기준으로 하여 모의를 수행하였다. 모의의 안정성을 확보한 이후에는 해당 댐지역의 하류영향을 고려한 문비제어를 반영한 다양한 방식의 수문운영 및 취수지점의 순간 수위 영향을 검토하였다. 그 결과로 본 모의에서는 특정한 수문의 운영 조건에서는 댐수위 계측지점과 인근 취수지점 간에도 0.2m 수준의 순간 수위차가 발생할 수 있음을 보였으며, 이는 경우에 따라 취수시설의 일시적 장애요소로 발생할 수 있음을 의미한다. 따라서, 현재의 취수구조물과 문비운영 특성에 따라 발생가능한 취수장애를 줄일 수 있는 운영조건의 탐색을 위해서 수치모의를 추가로 하였으며, 이 때 댐축 상류의 유속분포에 대한 추가 검토도 수행하였다. 다만, 댐에서 방류시 하류조건에 대한 검토는 추후 보강되어야 할 것으로 판단된다.

  • PDF

Investigation of Transient Performance of An Auxiliary Power Unit Microturbine Engine (보조동력용 마이크로터빈 엔진에 대한 과도성능 해석)

  • Son, Ho-Jae;Kim, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.20-28
    • /
    • 2007
  • The easiest way to see the phenomena of compressor surge is to show the static and dynamic operation characteristic on the map. Its operation zone will be restricted by the surge limit and, static and transient process must have some margin for it. Effect of rotor moment of inertia, air/gas volumes and heat transfer are factors to cause the transition from the static line. In case a large volume such as heat exchanger exists in the system it will exert a substantial influence to dynamic characteristics. In the present paper, influence of air volume bled from the compressor exit on transient process is investigated with an example of an auxiliary power unit micro-turbine engine. Turbine mass, pressure ratio, rotation speed, power and moment are calculated based on mass and work conservation. Result from the present study can give guidance to design the control system. A computer program is developed to calculate the dynamic process using the MathCAD commercial software.

The Development of the Climatic Design Tool for Energy Efficient Building Design (태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구)

  • Baek, Nam-Choon;Shin, U-Chul;Lee, Jin-Kook;Yoon, Eung-Sang;Yoon, Suk-Man
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.21-27
    • /
    • 2008
  • In this study, the design of the solar heating system for district heating as well as it's operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

The Decrease of Return Temperature by Improvement of the Consumer's Control System in District Heating (지역난방 열사용시설 자동제어시스템 개선을 통한 회수온도 저감 연구)

  • Ha, Seung-Kyu;Kim, Youn-Hong;Lee, Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.245-251
    • /
    • 2006
  • The main idea of this study is to turn attention on the question of good cooling ability of customer substations in large district heating networks. The main reason for that is based on our experience that the optimization of district heating very often is directed toward production, whereas questions of optimal distribution are neglected if only the necessary load can be supplied and the customer's request for comfort is met. Our view is that low return temperature(operational temperature differences, ${\Delta}T$) in district heating systems is an Important feature for efficient net operation and gives both economic and operational benefits to the district heating supplier Furthermore, it is as well a prerequisite for meeting the customers demand for reliable supply of the heat load. However, in many practical cases we have seen that district heating return temperatures are higher than necessary. Hence, the aim of the study is to propose and verify a method for detection of the most critical consumers of the net and to identify the reasons for resulting high return temperature. From the results, temperature control system is presented as one of the most important reason of high return temperature in DH networks.

  • PDF

Hydrological observation system deployment for water Water quantity, quality management (수자원 수량, 수질관리를 위한 수문관측시스템 구축방안)

  • Yu, Se-hwan;Jang, Dong-bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.882-885
    • /
    • 2014
  • The duration and frequency of flooding and not last long, by the time climate change drought. The increased accordingly by reducing stream flow and year variation. This trend is expected to continue, and change towards a comprehensive analysis of such quantity, quality and management of water resources are managed. Flood warning system is called to perform them electronically to the management of water resources such as these to be in the organic water-related basic data acquisition, storage, processing and utilization. Can be divided into hydrological observations and flood warning systems alert system broadcast system. Hydrological observation system is the measurement from the hydrological stations (water level, rainfall, water) that can be observed hydrological status of the dam basin hydrological observation data transmitted to the central office, located at the dam monitoring and control system through a variety of networks including satellite, and the collected defined as the system that sent the K-water head office in 1 minute increments hydrological observation data. Headquartered in support of this decision. Dimensions of the dam are provided in addition to inward. Channeled through various hydrologic analysis and leveraging the data transfer. This paper looks at ways to build out hydrological observation system.

  • PDF

Development of optimum pump operation technique for the damage rate reduction of water distribution system (상수도관망의 피해율 저감을 위한 가압장 최적운영기법 개발)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.5
    • /
    • pp.373-380
    • /
    • 2019
  • In this study, the optimum pump operation technique is suggested to decrease the damage rate of water distribution system. Pump operation system was developed to achieve the effective pump operation. Pressure sensors which can communicate with pumps are installed at the end of water distribution system. Pump operation system can control the pressure of water pump according to data sent from the pressure sensors. Therefore, water distribution system can reduce the pressure and maintain enough pressure which can supply the demand of water users. For proving effectiveness of new system, reliability model was introduced to compare the results of damage rates between the maintaining high pressure and selective pressure in water pump. Unsteady analysis was conducted with several scenarios. And the results were used to calculate the probability of pipe breakage. From the results, it was found that new pump operation system can reduce the energy usage and probability of pipe breakage by applying to pumps.