• Title/Summary/Keyword: 유량 제어시스템

Search Result 350, Processing Time 0.04 seconds

Numerical Study on Reduction in Frictional Loss for a Sandwitch Type of Pressure Regulator (정압기의 유체력 손실 저감에 대한 수치해석적 연구)

  • Seo, Dong-Kyun;Lee, Jung-Hoon;Hwang, Jung-Ho;Kim, Kwang-Soo;Kim, Kang-Dae;Kim, Dong-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.47-52
    • /
    • 2010
  • The development of energy saving system with pressure regulator has recently been received interests. Since the internal geometry in the pressure regulator is small and complex, the frictional loss in it is critical. In this study, the pressure loss with tip size, tip position, and mass flow was investigated using numerical approaches(CFD). The aimed reduction in pressure were achieved as the ratio of t/T was more than 0.8. In addition, there was no effect of the tip position.

A Study of Combustion Test Facility for LRE Using Hydrogen peroxide and Kerosene as Propellant (과산화수소/케로신 액체로켓엔진의 연소시험 설비 개발에 관한 연구)

  • Choi, Yu-Ri;Jeon, Jun-Su;Kim, Young-Mun;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.29-32
    • /
    • 2009
  • This study is for development combustion test facility of liquid rocket engine system using hydrogen peroxide/kerosene as propellent. For this new facility, we construct thrust measure system, propellent supply system, control and data acquisition system. To perform 200N liquid rocket engine combustion test, operation scenario and sequence were designed. Result of combustion test propellents were supplied to engine stably and confirm of development combustion test facility very well.

  • PDF

Assessment of impact on Pollution load in First-flush Overflows in Jungnangcheon (초기우수월류가 중랑천 오염부하량에 미치는 영향 평가)

  • Shin, Jea Whan;Jang, Suk Hwan;Jo, Jun Won;Park, Seung Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.334-334
    • /
    • 2020
  • 우리나라는 서울지역과 수도권 위성도시의 인구분포가 집중되어있으며, 도시지역에 대한 관거 우선 확충에 따라 하수처리구역의 비율이 점차 늘어나고 있다. 초기우수월류에 의한 오염은 비점오염원의 경우로, 발생 및 배출경로가 다양하고 불특정하게 발생한다. 비점 오염원의 유출 농도는 강우 초기에 높게 나타나고, 점차 농도가 낮아지는데, 이러한 강우 특성을 고려하여 오염발생량을 규명하는 것이 필요하다. 이에 따라 본 연구에서는 중랑천 의정부 지역을 대상지역으로 선정하여, 합류식 하수관거 월류부하를 하수도법 관리수준으로 제어하기 위한 초기우수 처리대상 강우량을 산정하고 강우분포형 및 토지이용도 현황별로 초기월류유량 및 부하특성을 검토하였다. 본 연구에서는 SWMM(Strom Water Management Moder)모형을 적용하여, 매년 홍수기에 발생할 수 있는 다양한 강우분포를 고려하여 대상유역의 토지용도별 합류식 처리구역에 대하여 SWMM 모형의 검·보정 절차를 통해 예측값과 측정값 사이의 상관관계를 분석하였고, 의정부 지역의 초기우수월류 오염부하량의 토지용도에 따른 경향성과, 강우량 및 강우분포, 배수면적에 따른 경향성을 비교하였다.

  • PDF

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

Measurements of Greenhouse Gas from the Manure in the Piggery (축산 돈사에서 온실가스 측정 방법에 대한 연구)

  • Kam, D.H.;Park, K.H.;Choi, D.Y.;Jung, M.S.;Min, B.R.;Lee, D.W.;Kim, J.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.155-162
    • /
    • 2011
  • This study was conducted to suggest the measurement procedure and to build up national greenhouse gas inventory database of animal agricultural sector by assessing methane and nitrous oxide emissions according to IPCC guidelines for national greenhouse gas inventory report in order to correspond to the Climate Change Convention. Ten house-made steady-state Half dome floating chambers were used to collect air samples emitted from slurry stored in the pit under the slat. Those chambers were spread out in order that air samples might represent the whole area of slurry under the slat. Fresh air was pumped into the chambers by $5{\sim}9{\ell}/min$ and air inside the chambers was sampled by $1{\ell}/min$. Surplus air by the higher flow rate of fresh air than sampling flow rate was passed through a hole on the top of chambers. Nitrous oxide fluxes measured from 10 locations would be negligible as concentrations between background air and sampled air from the chambers were within the error range. However, mean $CH_4$ fluxes were $0.15{\sim}1.02mg/m^2{\cdot}s$. The application of continuous greenhouse gas measurement techniques would be preferred if the patterns of greenhouse gas emissions are considered.

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter(II) -Structural Improvement (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(II) -구조개선을 중심으로)

  • Kim, Jin-Uk;Jung, Yu-Jin;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.985-992
    • /
    • 2011
  • The 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics and flow distribution for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. Three types of modifications such as i) changing the plenum shape, ii) orifice install in the exit part of cleaned gas, iii) increasing the plenum number were established. From the results of computational fluid dynamics, it was revealed that the changing of plenum shape and orifice install in the exit part of cleaned gas was more reasonable than the increasing the plenum number because of the difficulties of retrofit. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, save the installation area, save the operation fee, and management more convenient.

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I))

  • Kwon, Young-Hyun;Kim, Jin-Uk;Jung, Yu-Jin;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4656-4663
    • /
    • 2010
  • In this study, the 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics, flow distribution, air mean ages, and residence time for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. In addition, it showed the possibility that the velocity field and distribution characteristics of the residence time could be improved through a modification to inlet structure of the spray dryer reactor. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, the installation area, the operation fee, and management more convenient.

Conceptual eco-hydrological model reflecting the interaction of climate-soil-vegetation-groundwater table in humid regions (습윤 지역의 기후-토양-식생-지하수위 상호작용을 반영한 개념적인 생태 수문 모형)

  • Choi, Jeonghyeon;Kim, Sangdan
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.9
    • /
    • pp.681-692
    • /
    • 2021
  • Vegetation processes have a significant impact on rainfall runoff processes through evapotranspiration control, but are rarely considered in the conceptual lumped hydrological model. This study evaluated the model performance of the Hapcheon Dam watershed by integrating the ecological module expressing the leaf area index data sensed remotely from the satellite into the hydrological partition module. The proposed eco-hydrological model has three main features to better represent the eco-hydrological process in humid regions. 1) The growth rate of vegetation is constrained by water shortage stress in the watershed. 2) The maximum growth of vegetation is limited by the energy of the watershed climate. 3) The interaction of vegetation and aquifers is reflected. The proposed model simultaneously simulates hydrologic components and vegetation dynamics of watershed scale. The following findings were found from the validation results using the model parameters estimated by the SCEM algorithm. 1) Estimating the parameters of the eco-hydrological model using the leaf area index and streamflow data can predict the streamflow with similar accuracy and robustness to the hydrological model without the ecological module. 2) Using the remotely sensed leaf area index without filtering as input data is not helpful in estimating streamflow. 3) The integrated eco-hydrological model can provide an excellent estimate of the seasonal variability of the leaf area index.

Preceding Study on the Sensing Part of Level Measurement System of Launch Vehicle Propellant Tanks (발사체 탱크 추진제 수위 측정시스템 감지부 선행연구)

  • Shin, Dong-Sun;Lee, Eung-Shin;Ko, Hyun-Seok;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.54-57
    • /
    • 2009
  • The propellant level measurement system of the next Koreanized launch vehicle shall adapt a capacitive type sensor, which can generate capacitive values continuously considering cryogenic environment and the characteristics of flowrate control. At present there are a twin-arc and a triple-arc methods as a capacitive type signal sensing method. In this study a highly accurate triple-arc method, which can apply to almost all fluids, is chosen. In this paper the review results on the principle of triple-arc sensing, the analysis results on the influence on capacitive values due to shape change of sensing part, and the simulation results to monitor the influence on signal sensing according to the location of sensing part in the upper part of propellant tank are included. Information obtained from this study can be used in the designing and manufacturing of on-board propellant level measurement system in tanks.

  • PDF

Discharge Variation of Perforated Hoses and Drip Irrigation Systems for Protected Cultivation (시설재배용 분수호스 및 점적관수 시스템의 관수균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.297-302
    • /
    • 2007
  • Discharge variations of perforated hose and drip irrigation systems were examined to evaluate irrigation uniformity at different pressures and length of branch line. Evaluation using statistical uniformity indicated that button drippers performed at excellent level but drip tapes and drip hoses were a little lower level. Nominal discharge of drip irrigation systems showed at the high side within the range of regulating pressure provided by the manufacturer. It is desirable that the length of branch line for drip hose, drip tape, and button dripper should be limited to 50 m, 70 m, and 100 m, respectively. Irrigation uniformity of perforated hoses showed very low level. So it is recommended that the length of branch line for perforated hoses should be limited to $30{\sim}35m$.