• Title/Summary/Keyword: 유량함수

Search Result 393, Processing Time 0.033 seconds

TFN model application for hourly flood prediction of small river (소규모 하천의 시간단위 홍수예측을 위한 TFN 모형 적용성 검토)

  • Sung, Ji Youn;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.165-174
    • /
    • 2018
  • The model using time series data can be considered as a flood forecasting model of a small river due to its efficiency for model development and the advantage of rapid simulation for securing predicted time when reliable data are obtained. Transfer Function Noise (TFN) model has been applied hourly flood forecast in Italy, and UK since 1970s, while it has mainly been used for long-term simulations in daily or monthly basis in Korea. Recently, accumulating hydrological data with good quality have made it possible to simulate hourly flood prediction. The purpose of this study is to assess the TFN model applicability that can reflect exogenous variables by combining dynamic system and error term to reduce prediction error for tributary rivers. TFN model with hourly data had better results than result from Storage Function Model (SFM), according to the flood events. And it is expected to expand to similar sized streams in the future.

Numerical Signal Prediction and Calibration Using the Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Slug Flow (슬러그 2상유동에서 전류형식 전자기유량계 수치적 신호예측 및 보정)

  • Ahn Yeh-Chan;Oh Byung Do;Kim Jong-Rok;Kim Moo Hwan;Kang Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.671-686
    • /
    • 2005
  • The transient nature and complex geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et al.). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. The velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method, and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for simulating slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are proposed for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

Stochastic Modelling of Monthly flows for Somjin river (섬진강 월유출량의 추계학적 모형)

  • 이종남;이홍근
    • Water for future
    • /
    • v.17 no.4
    • /
    • pp.281-291
    • /
    • 1984
  • In our Koreans river basins there are many of monthly rainfall data, but unfortrnately streamflow data needed are rare. Analysing monthly rainfall data of Somjin river basin, the stochastic theory model for calculation of monthly streamflow series of that region is determined. The model is composed of Box & Jenkins stansfer function plus ARIMA residual models. This linear stochastic differenced time series equation models can adapt themselves to the structure and variety of rainfall, streamflow data on the assumption of the stationary covarience. The fiexibility of Box-Jenkins method consists mainly in the iterative technique of building an AIRMA model from observations and by the use of autocorrelation functions. The best models for Somjin river basin belong to the general calss: $Y_t=($\omega$o-$\omega$_1B) C_iX_t+$\varepsilon$t$ $Y_t$ monthly streamflow, $X_t$ : monthly rainfall, $C_i$ :monthly run-off, $$\omega$o-$\omega$_1$ : transfer parameter, $$\varepsilon$_t$ : residual The streamflow series resulted from the proposed model is satisfactory comparing with the exsting streamflow data of Somjin gauging station site.

  • PDF

Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow (슬러그류 액상속도 측정용 전류형식 전자기유량계 개발)

  • Kang, Deok-Hong;Ahn, Yeh-Chan;Kim, Jong-Rok;Oh, Byung-Do;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF

The Integration of Rainfall-Runoff Model and Hydraulic Model for Flood Forecasting and Warning System in Nakdong River Basin (낙동강 유역에서의 홍수예.경보를 위한 강우-유출 모형과 수리해석모형의 연계)

  • Kim, Tae-Hyung;Kim, Kwang-Moon;Kim, Pan-Gu;Han, Kun-Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.640-640
    • /
    • 2012
  • 낙동강 홍수예경보 시스템은 낙동강 유역의 홍수피해 방지를 위해 1986년에 구축되어 낙동강홍수통제소에서 운영되어 온 이래로 여러 차례에 거친 시스템의 개선 및 보완을 통해 현재의 시스템을 갖추게 되었다. 그러나 4대강 사업을 통해 시행된 하도 준설 및 보 설치로 인한 하도 조건의 변경과 기존의 저류함수모형 및 수위-유량 관계식을 이용한 수위예측의 한계로 인해 낙동강 하도에 대한 수리해석모형 구축의 필요성이 대두되었다. 이에 따라 낙동강 홍수통제소에서는 기존의 저류함수모형을 이용한 강우-유출 해석모형과 낙동강 본류 및 주요 지류에 대한 수리해석 모형을 구축하여 연계하는 과업을 수행 중에 있다. 본 연구에서는 하천기본계획의 설계홍수량의 산정시 적용되는 HEC-HMS 모형을 통해 강우-유출해석모형을 구축하고, 낙동강 본류 및 8개 지류에 대해 FLDWAV 모형을 이용해 수리해석 모형을 구축하여 연계하였다. 수자원단위지도의 표준유역과 수위관측소 지점을 기반으로 하여 낙동강 유역을 287개의 소유역으로 분할하였고, 271개의 분할하도 및 10개의 다목적 댐 방류량을 반영하여 강우-유출 모형을 구축하였다. 수치지형도 및 토양도, 토지이용현황도를 통해 유역유출 및 하도유출에 대한 매개변수 산정하였고, 낙동강 본류 및 지류내의 주요 수위관측소를 유량의 검보정 지점으로 설정하였다. 수리학적 모형 구축을 위해 낙동강 본류의 383개의 단면 및 8개 지류의 497개 단면을 반영하였고, 그 이외의 6개 주요 지류는 측방유입으로 처리하였으며 낙동강 본류에 신설된 8개의 다기능보의 운영을 반영하였다. 각각 구축된 강우-유출 모형과 수리학적 모형은 모듈화하여 연계하였으며, 현재 낙동강홍수통제소에서 운영되고 있는 낙동, 왜관, 현풍, 진동, 삼랑진, 구포, 동촌수위관측소를 홍수예보지점으로 선정하여 모형의 검보정을 실시하였다. 구축된 모형은 낙동강홍수통제소의 홍수예보모형의 계산결과와 비교하여 적용성 및 효율성을 입증할 수 있을 것으로 판단되며, 낙동강에서의 실시간 홍수예 경보를 위한 홍수예보모형으로 활용될 수 있을 것으로 사료된다.

  • PDF

Unsteady Flow Analysis in the Youngsan River Using Explicit and Implicit Finite Difference Methods (양해법과 음해법을 이용한 영산강에서의 부정류해석)

  • Choi, Sung-Uk;Yeo, Woon-Kwang;Choo, Cheol;Kim, Chang-Wan;O, Yu-Chang
    • Water for future
    • /
    • v.24 no.4
    • /
    • pp.49-58
    • /
    • 1991
  • Flood routing in the Youngsan River was performed for the flood event of July, 1989 by two finite difference methods. The Saint Venant eq., a kind of hyperbolic partial differential equation is employed as governing equation and the explicit scheme (Leap Frog) and implicit scheme (Preissmann) are used to discretize the GE. As for the external boundary conditions, discharge and tidal elevation are upstream and downstream BC, respectively and estuary dam is included in internal BC. Lateral inflows and upstream discharges are the hourly results from storage function method, At Naju station, a Relatively upstream points in this river, the outputs are interpreted as good ones by comparing two numerical results of FDMs with the observed data and the calibrated results by storage function method. and two computational results are compared at the other sites, from middle stream and downstream points, and thus are considered reliable. Therefore, we can conclude from this research that these numerical models are adaptable in simulating and forecasting the flood in natural channels in Korea as well as existing hydrologic models. And the study about optimal gate control at the flood time is expected as further study using these models.

  • PDF

Analysis of Runoff Sensitivity for Initial Soil Condition in Distributed Model (초기토양조건에 대한 분포형모형 유출민감도 분석)

  • Park, Jin Hyeog;Hur, Young Teck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4B
    • /
    • pp.375-381
    • /
    • 2008
  • In this research, a physics based grid-multi layer distributed flood runoff model was developed to analyze discharge for the Namgang Dam Watershed ($2,293km^2$) and applied for sensitivity analysis for estimation of parameters, mainly initial soil moisture condition and saturate infiltration coefficient, which have a strong influence on discharge. Capability of the model was evaluated using VER and QER from the results of rainfall-runoff analysis and showed enhanced results of 6% compared to parameters before calibration. As the result with the sensitivity analysis of parameters, the part of the most influence on the runoff was the infiltration coefficient and ratio of layer partition. The total discharge and peak time showed comparatively precise runoff results without the initial calibration of the parameters.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Probable Volcanic Flood of the Cheonji Caldera Lake Triggered by Volcanic Eruption of Mt. Baekdusan (백두산 화산분화로 인해 천지에서 발생 가능한 화산홍수)

  • Lee, Khil-Ha;Kim, Sung-Wook;Yoo, Soon-Young;Kim, Sang-Hyun
    • Journal of the Korean earth science society
    • /
    • v.34 no.6
    • /
    • pp.492-506
    • /
    • 2013
  • The historical accounts and materials about the eruption of Mt. Baekdusan as observed by the geological survey is now showing some signs of waking from a long slumber. As a response of the volcanic eruption of Mt. Baekdusan, water release may occur from the stored water in Lake Cheonjii caldera. The volcanic flood is crucial in that it has huge potential energy that can destruct all kinds of man-made structures and that its velocity can reach up to 100 km $hr^{-1}$ to cover hundreds of kilometers of downstream of Lake Cheonji. The ultimate goal of the study is to estimate the level of damage caused by the volcanic flood of Lake Cheon-Ji caldera. As a preliminary study a scenario-based numerical analysis is performed to build hydrographs as a function of time. The analysis is performed for each scenario (breach, magma uplift, combination of uplift and breach, formation of precipitation etc.) and the parameters to require a model structure is chosen on the basis of the historic records of other volcanos. This study only considers the amount of water at the rim site as a function of time for the estimation whereas the downstream routing process is not considered in this study.

Application of EOC Images to Developed the GIUH (지형학적순간단위유랑도 분석을 위한 EOC 스테레오 영상 활용)

  • Choi, Hyun;Kang, In-Joon;Hong, Sun-Heun
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.2
    • /
    • pp.91-102
    • /
    • 2004
  • This paper reflects the estimation of using the EOC(Electro-optical Camera) images supporting GIUH(geomorphological instantaneous unit hydrograph) approach. We have analyzed GIUH in its density and frequency distribution by creating a DEM(digital elevation model) for the sub basin produced from the EOC images and examined topographical and hydrological application possibility of the EOC images. In this process, we have topographical basin characteristic analysis that use the remote sensing technique analyzing the DEM creation process of the EOC stereo images by studying the basic topographical hydrology analysis about abstraction technique since it is flirty complex and is more time-consuming than other method. we executed statistical analysis of a basin size and river length using the frequency function after divided lattice spacing applied have to the sub river basin from the image data and the digital map into 10m intervals ranging from 10m to 100m. After comparing and examining the peak and time to peak of the GIUH, we proceeded with a comparative analysis by lattice concerning the topographical divergence rate, area ratio, length ratio. Accumulating the peak and time to peak of the GIUH is altered to non-linear form in accordance to lattice dimension as well as basin factor. It was proved that the lattice dimension is one of the important factors about the peak and time to peak of the GIUH.