• Title/Summary/Keyword: 유동-구조 연성 해석

Search Result 73, Processing Time 0.02 seconds

Analysis method on Structural Safety Evaluation of Butterfly Valve of Piping for LNG carrier (LNG 선박용 배관에 사용되는 Butterfly Valve의 구조 안정성 평가에 관한 해석 기법)

  • Park, Young-Chul;Park, Han-Seok;Kim, Si-Pom
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.4
    • /
    • pp.76-81
    • /
    • 2008
  • A cryogenic butterfly valve is used to transfer the liquefied natural gas (LNG) which temperature is $-162^{\circ}C$. This valve is core part in the piping system using LNG. This paper performed coupling analysis using FEM to evaluate safety of cryogenic butterfly valve. Flow analysis is calculated numerically the CAE and CFD methods are useful to predict the thermal matter and the inner flow field of the valve. Thermal analysis and structural analysis used ANSYS Workbench.

  • PDF

Fluid-structure interaction analysis of two-dimensional flow around a moving cylinder (유체-구조 연성 기법을 사용한 움직이는 2차원 실린더 주위의 유동 해석)

  • Lee, Hee-Bum;Rhee, Shin-Hyung
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-74
    • /
    • 2011
  • Recently, thanks to the advanced computational power and numerical methods, it is made possible to analyze the flow around moving bodies using computational fluid dynamics techniques. In those simulations, moving mesh techniques should be able to represent both the body motion and boundary deformation, which are frequently encountered in fluid-structure interaction and/or six degree-of-freedom problems. In the present study, the staggered loosely coupling algorithm was used for fluid-structure interaction and the Laplacian operator based technique was used for moving mesh. For the verification of the developed computational method, the flow around a two-dimensional cylinder was simulated and analyzed.

  • PDF

Direct forcing/fictitious domain-Level set method for two-phase flow-structure interaction (이상 유동에서의 유체-구조 연성해석을 위한 Direct Forcing/Ficititious Domain-Level Set Method)

  • Jeon, Chung-Ho;Yoon, Hyun-Sik;Jung, Jae-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.36-41
    • /
    • 2011
  • In the present paper, a direct forcing/fictitious domain (DF/FD) level set method is proposed to simulate the FSI (fluid-solid interaction) in two-phase flow. The main idea is to combine the direct-forcing/fictitious domain (DF/FD) method with the level set method in the Cartesian coordinates. The DF/FD method is a non-Lagrange-multiplier version of a distributed Lagrange multiplier/fictitious domain (DLM/FD) method. This method does not sacrifice the accuracy and robustness by employing a discrete ${\delta}$ (Dirac delta) function to transfer quantities between the Eulerian nodes and Lagrangian points explicitly as the immersed boundary method. The advantages of this approach are the simple concept, easy implementation, and utilization of the original governing equation without modification. Simulations of various water-entry problems have been conducted to validate the capability and accuracy of the present method in solving the FSI in two-phase flow. Consequently, the present results are found to be in good agreement with those of previous studies.

A Study on Dehumidification Characteristics of Hollow Fiber Membrane Module for Pneumatic Power Unit Using Fluid-Solid Interaction Analysis (유동-구조 연성해석을 이용한 공압용 파워 유닛에 사용되는 중공사막 모듈에 대한 제습특성 연구)

  • Jeong, Eun-A;Khan, Haroon Ahmad;Lee, Kee-Yoon;Yun, So-Nam
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.65-73
    • /
    • 2019
  • In this study, flow analysis and fluid-solid interaction analysis were conducted on a hollow fiber membrane module used for analysis of dehumidification characteristics. To ensure the reliability of the flow analysis results, the dehumidification experiment was performed under the temperature of 30℃ and relative humidity of 30% RH. The results of the dehumidification experiments were compared with the flow analysis results. The results of dehumidification experiments and flow analysis had a difference of approximately 5%. A 1-Way fluid-solid interaction analysis with various materials was conducted. From the results, it was found that the baffle with the largest shape deformation (polyethylene material) was subjected to 2-way fluid-solid interaction. The analysis of fluid flow and dehumidification characteristics were analyzed according to the shape deformation of the baffle.

Internal Flow Characteristic Analysis and Deformation of Foil Considering Slip between Foils (Foil사이의 미끄러짐을 고려한 Foil Bearing변형 및 내부유동특성해석)

  • Lee, S.H.;Won, C.S.;Hur, N.;Jeon, S.B.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.482-487
    • /
    • 2001
  • Leaf type foil bearings have been used successfully in many aerospace applications such as air cycle machines, turbocompressors and turboexpander. These applications are characterized by light loads, constant speeds and low to moderate temperatures. But, as system on start-up or shutdown, sliding contact between the shaft and foil surfaces cause wear. So, in present study, to understand pressure-flow characteristics and deformation of foil bearing, flow/structure interaction analysis was used. and using this method, 2D and 3D calculation was peformed for shape of foil bearing to know circumferential direction flow and leakage flow characteristics of axial direction.

  • PDF

Investigation on Aerodynamic Performance of a Highly-Loaded Axial Fan with Active/Passive Flow Control Using FSI Analysis (유체-구조 연성해석을 이용한 능동/수동 유동제어방식이 결합된 고하중 축류 팬의 성능특성 연구)

  • Ma, Sang-Bum;Kim, Kwang-Yong;Choi, Jaeho;Lee, Wonsuk
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.1
    • /
    • pp.113-119
    • /
    • 2017
  • An investigation on aerodynamic performance of a highly-loaded axial fan has been conducted to find the effects of tip injection and casing groove on aerodynamic performance in this study. Three-dimensional Reynolds-averaged Navier-Stokes equations with $k-{\varepsilon}$ turbulence model were used to analyze the fluid flow in the fan with Fluid-Structure Interaction (FSI) analysis. The hexahedral grid was used to construct computational domain, and the grid dependency test drew the optimal grid system. FSI analysis was also carried out to predict the deformation of rotor and stator blades, and the effect of deformation on the aerodynamic performance of axial fan was analyzed compared to the performance predicted without FSI analysis.

A Study of the Vibration of an Axial Flow Pump through FSI Analysis Method (유체-구조 연성해석을 통한 축류펌프의 진동 연구)

  • Lee, Bo-Ram;Yun, Tae-Jong;Oh, Won-Bin;Lee, Chung-Woo;Kim, Hak Hyoung;Jeong, Yeong Jae;Kim, Ill-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.107-112
    • /
    • 2021
  • Pressure, which is a dynamic characteristic of a floodgate, is predicted using an FSI analysis method. A fluid analysis model and a hydrology analysis model were used as analysis models. As a result of the analysis, we found that a warped model has smaller acceleration than a square model. Additionally, this numerical analysis technique was applied to the actual hydrology, and the analysis results were compared with the results of the vibration tests. As a result, we confirmed that there is a small difference between the results of the vibration tests and the results of the FSI analysis. Through this analysis, the applicability and reliability of the FSI analysis method were verified. We concluded that the pressure of a floodgate can be measured through an FSI analysis method.

A Fluid Analysis of a Container Crane using the Computation Fluid Dynamics (전산유동해석을 이용한 컨테이너 크레인의 유동 분석)

  • Kwon Soon-Kyu;Lee Seong-Wook;Han Dong-Seop;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.349-354
    • /
    • 2006
  • This study analyzed the fluid state around a container crone according to a wind direction when a wind load was applied to a container crone. The container crane for this research is a model of a 50-ton class used broadly in the current ports. The dimension of an external fluid field set up diameter, 300m, height, 200m. This study considered the change of a wind velocity according to an altitude in a criterion of a wind velocity, 50m/s, applying a power series law. An incident angle applied to an interval of 30 degrees in $0^{\circ}{\sim}180^{\circ}$ and this study carried out a computation fluid dynamics using a CFX-10. In this study, we indicate the wind pressure according to the height and section figure of each member. In addition, we suggest the wind pressure accordint to a wind direction. And we will analyze the structure stability of a container crone from the fluid-ductile analysis in the next study.

  • PDF

Lightweight Design of a Main Starting Air Valve through FSI Analysis (구조연성해석을 통한 메인스타팅 에어밸브의 경량화설계)

  • Lee, Kwon-Hee;Jang, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5371-5376
    • /
    • 2013
  • The role of a main starting air valve is to supply compressed air to the diesel engine for starting the stopped diesel engine of a ship and cut off the air during normal operation. In this study, the main starting air valve with 80mm size was designed based on the developed valve with 50mm size. The concept design of the 80A main starting air valve was completed by using CATIA. Then, fluid analysis was performed to investigate the flow characteristics such as pressure and velocity distribution. Sequentially, structural analysis using FSI was performed. In this study, ANSYS CFX and ANSYS Workbench are utilized. The heavy weight of the body can deteriorate the strength performance of neighbor elements, leading to undesirable effect on flow characteristics. Thus, in this research, a lightweight design of the body was suggested satisfying strength requirement. The weight of the suggested design was reduced by 7kg, and the strength satisfied its requirement.

Three Dimensional Electro-Fluid-Structural Interaction Simulation for Pumping Performance Evaluation of a Valveless Micropump (무밸브 마이크로 펌프의 성능평가를 위한 3차원 전기-유체-구조 상호작용 해석)

  • Pham, My;Phan, Van Phuoc;Han, Cheol-Heui;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.744-750
    • /
    • 2009
  • In this study, the pumping performance of a piezoelectric valveless micropump is simulated. The micropump, which was developed in the previous work, is composed of a four-layer lightweight piezocomposite actuator, a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, the fluid domain and the structural domain are coupled in the three-dimensional simulation. We used ANSYS for the piezoelectric and structural domains and ANSYS CFX for the fluid domain. The effects of driven frequency on the flow rate have been investigated by simulating the flow characteristics for 10 Hz and 40 Hz driven frequencies. The flow rates with respect to driven frequencies up to 300 Hz have been calculated.